• Title/Summary/Keyword: detecting accuracy

Search Result 991, Processing Time 0.031 seconds

Steel Plate Thickness Gauge by means of Gamma-Ray Backscattering (감마선 빽스켓터링을 이용한 철판 두께 측정에 관하여)

  • 김덕진;김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.1
    • /
    • pp.18-23
    • /
    • 1966
  • An experimental study of a steel plate thickness gauge by means of the measurements of backscatered gamma-rays has been carried out. The difference between this and other methods is that this method does not include any shilding matterials in the detecting probe, because the primary radiations and the backscattered radiations are detected simultaneously by an NaI (TI) scintillating crystal, and the activity of the Co-60 source used is low enough. In this thickness gauge, the thickness of the steel plates can be read directly on the counting ratemeter scale. The optimum conditions in the source-to-detector distance, window width of the analyzer, energy and strength of the gamma-ray source were found experimentally. The results have shown that the accuracy of the gauge was about $\pm$3% in the range of 3 to 8mm thickness. This gauge can be used to detect the pits or corrosions on the inner walls of the steel pipes.

  • PDF

Study on the Compact K-Band Radar for Detecting the Approaching Target above Ground (지상 접근 표적 감지를 위한 초소형 K-대역 레이다 연구)

  • Ha, Jong-Soo;Roh, Jin-Eep;Choi, Jae-Hyun;Lee, Han-Jin;Park, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.309-317
    • /
    • 2017
  • This paper proposes a compact K-band radar applied to a miniature proximity fuze for the active defense system. In this terrestrial environment, it is not easy to detect approaching small targets because the clutter is scattered. In addition, it is difficult to miniaturize the radar for the small proximity fuze while improving the target accuracy of the radar in such environments. To solve these difficulties, this study presents system analysis and design, antenna design, and transceiver and signal processor design of the compact K-band radar. Some test results are presented and the results are analyzed, the validity of the proposed study is examined.

Value of PAX1 Methylation Analysis by MS-HRM in the Triage of Atypical Squamous Cells of Undetermined Significance

  • Li, Shi-Rong;Wang, Zhen-Ming;Wang, Yu-Hui;Wang, Xi-Bo;Zhao, Jian-Qiang;Xue, Hai-Bin;Jiang, Fu-Guo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5843-5846
    • /
    • 2015
  • Background: Detection of cervical high grade lesions in patients with atypical squamous cells of undetermined significance (ASCUS) is still a challenge. Our study tested the efficacy of the paired boxed gene 1 (PAX1) methylation analysis by methylation-sensitive high-resolution melting (MS-HRM) in the detection of high grade lesions in ASCUS and compared performance with the hybrid capture 2 (HC2) human papillomavirus (HPV) test. Materials and Methods: A total of 463 consecutive ASCUS women from primary screening were selected. Their cervical scrapings were collected and assessed by PAX1 methylation analysis (MS-HRM) and high-risk HPV-DNA test (HC2). All patients with ASCUS were admitted to colposcopy and cervical biopsies. The Chisquare test was used to test the differences of PAX1 methylation or HPV infection between groups. Results: The specificity, sensitivity, and accuracy for detecting CIN2 + lesions were: 95.6%, 82.4%, and 94.6%, respectively, for the PAX1 MS-HRM test; and 59.7%, 64.7%, and 60.0% for the HC2 HPV test. Conclusions: The PAX1 methylation analysis by MS-HRM demonstrated a better performance than the high-risk HPV-DNA test for the detection of high grade lesions (CIN2 +) in ASCUS cases. This approach could screen out the majority of low grade cases of ASCUS, and thus reduce the referral rate to colposcopy.

Which Endometrial Pathologies Need Intraoperative Frozen Sections?

  • Balik, Gulsah;Kagitci, Mehmet;Ustuner, Isik;Akpinar, Funda;Guven, Emine Seda Guvendag
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.6121-6125
    • /
    • 2013
  • Background: Endometrial cancers are the most common gynecologic cancers. Endometrial sampling is a preferred procedure for diagnosis of the endometrial pathology. It is performed routinely in many clinics prior to surgery in order to exclude an endometrial malignancy. We aimed to investigate the accuracy of endometrial sampling in the diagnosis of endometrial pathologies and which findings need intra-operative frozen sections. Materials and Methods: Three hundred nine women applying to a university hospital and undergoing endometrial sampling and hysterectomy between 2010 and 2012 were included to this retrospective study. Data were retrieved from patient files and pathology archives. Results: There was 17 patients with malignancy but endometrial sampling could detect this in only 10 of them. The endometrial sampling sensitivity and specificity of detecting cancer were 58.8% and 100%, with negative and positive predictive values of 97.6%, and 100%, respectively. In 7 patients, the endometrial sampling failed to detect malignancy; 4 of these patients had a preoperative diagnosis of complex atypical endometrial hyperplasia and 2 patients had a post-menopausal endometrial polyps and 1 with simple endometrial hyperplasia. Conclusions: There is an increased risk of malignancy in post-menopausal women especially with endometrial polyps and complex atypia hyperplasia. Endometrial sampling is a good choice for the diagnosis of endometrial pathologies. However, the diagnosis should be confirmed by frozen section in patients with post-menopausal endometrial polyps and complex atypia hyperplasia.

Accuracy of Frozen Sections for Intraoperative Diagnosis of Complex Atypical Endometrial Hyperplasia

  • Turan, Taner;Karadag, Burak;Karabuk, Emine;Tulunay, Gokhan;Ozgul, Nejat;Gultekin, Murat;Boran, Nurettin;Isikdogan, Zuhal;Kose, Mehmet Faruk
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1953-1956
    • /
    • 2012
  • Objective: The purpose of this study was to correlate the histological diagnosis made during intraoperative frozen section (FS) examination of hysterectomy samples with complex atypical endometrial hyperplasia (CAEH) diagnosed with definitive paraffin block histology. Methods: FS pathology results of 125 patients with a preoperative biopsy showing CAEH were compared retrospectively with paraffin block pathology findings. Results: Paraffin block results were consistent with FS in 78 of 125 patients (62.4%). The FS sensitivity and specificity of detecting cancer were 81.1% and 97.9%, with negative and positive predictive values of 76.7%, and 98.4%, respectively. Paraffin block results were reported as endometrial cancer in 77 of 125 (61.6%) patients. Final pathology was endometrial cancer in 45.3% patients diagnosed at our center and 76.9% for patients who had their diagnosis at other clinics (p=0.018). Paraffin block results were consistent with FS in 62.4% of all cases Consistence was 98.4% in patients who had endometrial cancer in FS. Conclusion: FS does not exclude the possibility of endometrial cancer in patients with the preoperative diagnosis of CAEH. In addition, sufficient endometrial sampling is important for an accurate diagnosis.

Skin Color Based Hand and Finger Detection for Gesture Recognition in CCTV Surveillance (CCTV 관제에서 동작 인식을 위한 색상 기반 손과 손가락 탐지)

  • Kang, Sung-Kwan;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.1-10
    • /
    • 2011
  • In this paper, we proposed the skin color based hand and finger detection technology for the gesture recognition in CCTV surveillance. The aim of this paper is to present the methodology for hand detection and propose the finger detection method. The detected hand and finger can be used to implement the non-contact mouse. This technology can be used to control the home devices such as home-theater and television. Skin color is used to segment the hand region from background and contour is extracted from the segmented hand. Analysis of contour gives us the location of finger tip in the hand. After detecting the location of the fingertip, this system tracks the fingertip by using only R channel alone, and in recognition of hand motions to apply differential image, such as the removal of useless image shows a robust side. We explain about experiment which relates in fingertip tracking and finger gestures recognition, and experiment result shows the accuracy above 96%.

A Method for Detecting Program Plagiarism Comparing Class Structure Graphs (클래스 구조 그래프 비교를 통한 프로그램 표절 검사 방법)

  • Kim, Yeoneo;Lee, Yun-Jung;Woo, Gyun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.37-47
    • /
    • 2013
  • Recently, lots of research results on program comparison have been reported since the code theft become frequent as the increase of code mobility. This paper proposes a plagiarism detection method using class structures. The proposed method constructs a graph representing the referential relationship between the member variables and the methods. This relationship is shown as a bipartite graph and the test for graph isomorphism is applied on the set of graphs to measure the similarity of the programs. In order to measure the effectiveness of this method, an experiment was conducted on the test set, the set of Java source codes submitted as solutions for the programming assignments in Object-Oriented Programming course of Pusan National University in 2012. In order to evaluate the accuracy of the proposed method, the F-measure is compared to those of JPlag and Stigmata. According to the experimental result, the F-measure of the proposed method is higher than those of JPlag and Stigmata by 0.17 and 0.34, respectively.

A Static Analyzer for Detecting Memory Leaks based on Procedural Summary (함수 요약에 기반한 메모리 누수 정적 탐지기)

  • Jung, Yung-Bum;Yi, Kwang-Keun
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.7
    • /
    • pp.590-606
    • /
    • 2009
  • We present a static analyzer that detects memory leaks in C programs. It achieves relatively high accuracy at a relatively low cost on SPEC2000 benchmarks and several open-source software packages, demonstrating its practicality and competitive edge against other reported analyzers: for a set of benchmarks totaling 1,777 KLOCs, it found 332 bugs with 47 additional false positives (a 12.4% false-positive ratio), and the average analysis speed was 720 LOC/sec. We separately analyze each procedure's memory behavior into a summary that is used in analyzing its call sites. Each procedural summary is parameterized by the procedure's call context so that it can be instantiated at different call sites. What information to capture in each procedural summary has been carefully tuned so that the summary should not lose any common memory-leak-related behaviors in real-world C program. Because each procedure is summarized by conventional fixpoint iteration over the abstract semantics ('a la abstract interpretation), the analyzer naturally handles arbitrary call cycles from direct or indirect recursive calls.

Correlation between Bone Mineral Density Measured by Dual-Energy X-Ray Absorptiometry and Hounsfield Units Measured by Diagnostic CT in Lumbar Spine

  • Lee, Sungjoon;Chung, Chun Kee;Oh, So Hee;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.384-389
    • /
    • 2013
  • Objective : Use of quantitative computed tomography (CT) to evaluate bone mineral density was suggested in the 1970s. Despite its reliability and accuracy, technical shortcomings restricted its usage, and dual-energy X-ray absorptiometry (DXA) became the gold standard evaluation method. Advances in CT technology have reduced its previous limitations, and CT evaluation of bone quality may now be applicable in clinical practice. The aim of this study was to determine if the Hounsfield unit (HU) values obtained from CT correlate with patient age and bone mineral density. Methods : A total of 128 female patients who underwent lumbar CT for back pain were enrolled in the study. Their mean age was 66.4 years. Among them, 70 patients also underwent DXA. The patients were stratified by decade of life, forming five age groups. Lumbar vertebrae L1-4 were analyzed. The HU value of each vertebra was determined by averaging three measurements of the vertebra's trabecular portion, as shown in consecutive axial CT images. The HU values were compared between age groups, and correlations of HU value with bone mineral density and T-scores were determined. Results : The HU values consistently decreased with increasing age with significant differences between age groups (p<0.001). There were significant positive correlations (p<0.001) of HU value with bone mineral density and T-score. Conclusion : The trabecular area HU value consistently decreases with age. Based on the strong positive correlation between HU value and bone mineral density, CT-based HU values might be useful in detecting bone mineral diseases, such as osteoporosis.

Smart Phone Sensor-Based Indoor Location Tracking System for Improving the Location Error of the Radio Environment (무선 환경의 위치 정보 오차 개선을 위한 스마트폰 센서 기반 실내 위치 추적 시스템)

  • Lee, Dae-Young;Kang, Young-Heung
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.1
    • /
    • pp.74-79
    • /
    • 2015
  • In this paper, in order to improve the error is utilized to location tracking the smart sensor detects a walking information user, RSSI is to provide an indoor position tracking system that is capable of correcting an error in terms weak. The acceleration sensor is able to detect the activity in the user walking and detects the number of step and the moving distance using the same. The Direction sensor is utilized as a digital compass, to detect the moving direction of the user. As a result of detecting the walking information using the sensor, it can be showed that this proposed indoor positioning system has a high degree of accuracy for the number of steps and the movement direction. Therefore, this paper shows that the proposed technique can correct the error of the location information to be problem in the conventional indoor location system which uses the only Wi-Fi APs by estimating the user's movement direction and distance using the sensors in smartphone without an additional equipment and cost.