Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses

  • Kilinc, Halil Ibrahim;Kesim, Bulent;Gumus, Hasan Onder;Dincel, Mehmet;Erkaya, Selcuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2014
  • PURPOSE. This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. MATERIALS AND METHODS. Ninety-one square prism-shaped ($1{\times}1{\times}1.5mm$) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. RESULTS. The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). CONCLUSION. Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength.

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

SHEAR BOND STRENGTH OF COMPOSITE RESIN TO ENAMEL FOLLOWING ENAMEL MICROABRASION (Enamel Microabrasion을 시행한 법랑질과 복합레진의 전단결합강도)

  • Hong, Kee-Sang;Lee, Sang-Dae;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • Enamel microabrasion is a means by which superficial enamel discoloration is removed using hydrochloric acid and fine pumice. As enamel microabrasion alone may not be sufficient in cases of deeper discoloration, composite resin restoration is recommended in areas where there is remaining discoloration. The purpose of this study was to investigate the effects of different methods and number of applications of enamel microabrasion on the shear bond strength of composite resin to enamel. Untreated control was designated as group 1. 5-second applications of a mixture of 18% HCl and fine pumice were performed 5 and 10 times on groups 2 and 3, respectively. A commercially available mixture of 10% HCl and abrasives(PREMA) was applied using a 10 : 1 gear reduction handpiece 5 and 10 times on groups 4 and 5, respectively, with each application lasting 20 seconds. After etching with 37% phosphoric acid, composite resin was bonded. Thermocycling was performed and shear bond strength was measured. The following results were obtained : 1. Group 2 showed the highest bond strength$(24.36{\pm}3.34)$, while group 3 showed the lowest$(19.35{\pm}3.43)$, Shear bond strength decreased in the following order: 2>4>5>1>3. 2. Group 2 showed bond strength significantly higher compared to groups 1 and 3(p<0.05). 3. There were no significant differences between groups 2 and 3, which had been microabraded using HCl and pumice, and groups 4 and 5, to which PREMA had been applied, when bond strengths were compared(p>0.05). 4. When modes of fracture were examined, adhesive failure was observed in groups 3 and 4, while cohesive failure was observed in groups 1, 2, 3 and 4. Only mixed failures were found group 5. 5. When viewed using a SEM, groups 2 and 3, which had been microabraded using HCl and pumice, showed surface appearances similar to that of enamel etched with phosphoric acid. Groups 4 and 5, treated with PREMA, exhibited a smooth surface similar to that of group 1. All oops showed similar, typical surface characteristics following phosphoric acid etching.

  • PDF

MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING BY SURFACE TREATMENT AND CURING TIME (치면열구전색제의 표면처리와 중합시간 증가에 따른 미반응 모노머 용리 평가)

  • Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.122-129
    • /
    • 2007
  • The purpose of this study was to evaluate the effects of a various light curing time on the residual monomers released from light-cured dental sealant, and to examine the effectiveness of surface treatment in reducing the oxygen-inhibited layer of light-cured dental sealant($Helioseal^{(R)}$ F, Vivadent, Liechtenstein). Specimens were cured with a halogen light curing unit(XL 3000, 3M, USA) for 20, 40, 60s. Surface treatment of a light-cured dental sealant included no treatment(control group), a 10-seconds exposure to distilled water(Group I), 10-seconds manual application using a cotton pellet wetted with 75% alcohol(Group II), and 10-seconds application of a water/pumice slurry using a rubber cup on a slow-speed handpiece The specimens were eluted in distilled water for 10 minutes. All elutes were analyzed by HPLC for identification and quantitive analysis of monomers. The results of this study can be summarized as follows. 1. None of the chromatograms of the tested sealant displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 2. The release of TEGDMA decreased with increasing curing time in conventional halogen light. 3. All surface treatment group had a decrease of monomer release in comparison with no treatment group. 4. Treatment that Group III eliminated the greatest amount of any type of residual monomers. 5. The elution of unreacted monomers from curing with halogen curing unit for 60s and Group III was less than other groups.

  • PDF

EFFECT OF TEFLON MEMBRANE AND NYLON MEMBRANE ON GUIDED BONE REGENERATON IN RABBIT TIBIA (가토 경골 골결손부에서 Nylon Membrane과 Teflon Membrane의 골유도 재생 효과)

  • Kim, Kwan-Shik;Cho, Byoung-Ouck;Lee, Young-Chan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.146-153
    • /
    • 2000
  • The purpose of present study is comparing the effect of Teflon Membrane and Nylon Membrane on bone regeneration in rabbit tibia. The 6 defects of $8{\times}8{\times}5mm$ size were drilled with dental handpiece in rabbit tibia, which on left side as an order of Control group(no coverage), Group 1(Nylon $5{\mu}m$ size), Group 3(Nylon $10{\mu}m$ size), and on right side Control group, Group 2($5{\mu}m$ Teflon), Group 4($10{\mu}m$ Teflon). Animals were killed at 7, 10, 14, 42 days to make specimens and observed the difference of healing potentials with light microscopy. The results were as follows ; 1. New bone formation has taken place at 14 days in Guided Bone Regeneration (GBR) group comparing to the Control group of massive inflammatory status. 2. Larger pore membrane allows more favorable healing potentials. Bone formation started earlier in larger membrane pore groups than smaller groups, until 14 days. 3. Bone forming potentials of Teflon membrane group was higher than Nylon membrane groups, Control group has the lowest bone forming potentials. 4. New bone formation was almost ended in 42 days, and there was no difference of bone formation between Nylon and Teflon membrane group of different size. There was no difference of bone formation at final stage(42 days) between Nylon membrane and Teflon membrane of same pore size. So nylon membrane may be clinically usable in guided bone regeneration case with further studies.

  • PDF

AN EVALUATION OF ROTATIONAL STABILITY IN ENDODONTIC ELECTRONIC MOTORS (근관치료용 전기모터의 회전 안정성 평가)

  • Park, Se-Hee;Seo, Hyun-Woo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.246-256
    • /
    • 2010
  • The purpose of this study was to evaluate a rotational stability of endodontic electronic motors by comparing the changes of rotational speed, depending on the number of usages and with/without static load. Twelve new endodontic electronic motors were used in this study. Non contact type digital tachometer was used for measuring the rotational speed of handpiece. True RMS Multimeter was used for measuring the voltages and the electric currents. All measurements were recorded every 10 seconds during 10 minutes and repeated 9 times. Five repetition was done per each electronic motor. To statistical analysis, student t-test, repeated measures and Scheffe's post-hoc tests were performed. In the same motor group, there was no significant difference in all measurements. In all groups, there was no significant difference in the amount of rotational speed changes depending on the number of usages and with/without static load. In the limitation of this study, the results showed that all kinds of endodontic electronic motors in this study had an established rotational stability. Therefore they could be safely used in root canal treatment with a reliable maintenance of rotational speed, regardless of the number of usages and with/without load.

The comparative study of user satisfaction on various implant engine system (다양한 임플란트 엔진 시스템에 대한 사용자 만족도 비교)

  • Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.9-15
    • /
    • 2014
  • Purpose: Implant engine system is composed of the handpiece, micromotor, control box and foot switch. The aim of this study was to evaluate the satisfaction of the implant engine systems in terms of convenience-design and to examine the relation with the experience of implant surgery. Materials and Methods: Three implant systems were evaluated: SurgicXT/X-SG20L, INTRAsurg300/CL3-09, XIP10/CRB26LX. For this comparative study, 30 dentists were included and the satisfaction was measured using a structured questionnaire. One-way analysis of the variance (ANOVA) and multiple regression analysis were used within and between the groups. Results: Total satisfaction differed from each other (P < 0.05). The convenience score was more associated with the total satisfaction than design score. Moreover, the implant surgery experience affected several assessments. Conclusion: Collectively, in a cross-sectional study model, the design of implant system significantly affects its total satisfaction and the surgery experience can be influential factor in the evaluation of implant engine system.

Immediate effect of Nd:YAG laser monotherapy on subgingival periodontal pathogens: a pilot clinical study

  • McCawley, Thomas K.;McCawley, Mark N.;Rams, Thomas E.
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.1
    • /
    • pp.77-87
    • /
    • 2022
  • Purpose: This pilot study assessed the immediate in vivo effect of high peak pulse power neodymium-doped yttrium aluminum garnet (Nd:YAG) laser monotherapy on selected red/orange complex periodontal pathogens in deep human periodontal pockets. Methods: Twelve adults with severe periodontitis were treated with the Laser-Assisted New Attachment Procedure (LANAP®) surgical protocol, wherein a free-running, digitally pulsed, Nd:YAG dental laser was used as the initial therapeutic step before mechanical root debridement. Using a flexible optical fiber in a handpiece, Nd:YAG laser energy, at a density of 196 J/cm2 and a high peak pulse power of 1,333 W/pulse, was directed parallel to untreated tooth root surfaces in sequential coronal-apical passes to clinical periodontal probing depths, for a total applied energy dose of approximately 8-12 joules per millimeter of periodontal probing depth at each periodontal site. Subgingival biofilm specimens were collected from each patient before and immediately after Nd:YAG laser monotherapy from periodontal pockets exhibiting ≥6 mm probing depths and bleeding on probing. Selected red/orange complex periodontal pathogens (Porphyromonas gingivalis, Tannerella forsythia, Prevotella intermedia/nigrescens, Fusobacterium nucleatum, Parvimonas micra, and Campylobacter species) were quantified in the subgingival samples using established anaerobic culture techniques. Results: All immediate post-treatment subgingival biofilm specimens continued to yield microbial growth after Nd:YAG laser monotherapy. The mean levels of total cultivable red/orange complex periodontal pathogens per patient significantly decreased from 12.0% pretreatment to 4.9% (a 59.2% decrease) immediately after Nd:YAG laser monotherapy, with 3 (25%) patients rendered culture-negative for all evaluated red/orange complex periodontal pathogens. Conclusions: High peak pulse power Nd:YAG laser monotherapy, used as the initial step in the LANAP® surgical protocol on mature subgingival biofilms, immediately induced significant reductions of nearly 60% in the mean total cultivable red/orange complex periodontal pathogen proportions per patient prior to mechanical root instrumentation and the rest of the LANAP® surgical protocol.

Strength Analyses of New 2- and 3-Axis-Type Small Multiplying Gears in Dental Hand-Pieces (치과드릴 구동용 신 소형 2축 및 3축형 증속기어 강도특성 비교)

  • Kim, Cheol;Kim, Ju-Yeong;Lee, Jung-Ho;Kwak, Se-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1027-1032
    • /
    • 2012
  • Two types of very small multiplying gears and arrays have been developed for new dental hand-pieces, and the increased speed ratios, modules, number of teeth, gear diameters, and gear types were calculated based on the dynamics of the machinery. The contacting and bending strengths were evaluated for gear teeth with two design concepts using AGMA equations and finite element analyses, and the contacting stresses on teeth with and without DLC (diamond-like-carbon) coating layers were calculated. Fatigue and tension tests were performed to obtain an S-N curve, the Young's modulus, and the strength of the gear material, and these were utilized in the analyses. Slightly larger stresses were found for 2-axis-type gears than for other types of gears, and the S-N curves showed that a gear lifetime of 109 cycles was satisfied. The contacting stresses in gears coated with DLC were reduced by 30%. A new prototype model of a hand-piece with small gears was successfully fabricated and tested.

The Evaluation of RPM Change in X-Smart According to Power Source: Endodontic Wireless Electronic Motor (근관치료용 무선전기모터인 X-Smart의 전원의 종류에 따른 RPM 변화의 평가)

  • Park, Se-Hee;Jeong, Dong-Bin;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.91-97
    • /
    • 2011
  • The purpose of this study was to evaluate RPM maintenance in X-Smart according to the power supplied by the AC adapter and rechargeable battery. Five new X-Smart were used in this study. A handpiece with rubber disk which has reflective tape was mounted on the vice. To measure the RPM, a non-contact type digital tachometer was used. RPM measurements were recorded every 5 minutes to 180 minutes and repeated 3 times per motor from each power source. To evaluate a difference of the RPM changes, two-way repeated measures were performed using $SPSS^{TM}$ 14.0. All tests were conducted at the 95 percent confidence level. There was no significant difference in the RPM change between the power sources. Continuous use of X-Smart with a rechargeable battery for up to 180 minutes could be safely used as an endodontic wireless motor with a reliable RPM maintenance.