• Title/Summary/Keyword: dental Technology

Search Result 2,241, Processing Time 0.033 seconds

Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report (만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례)

  • Min-Jae Park;Ji-Won Bang;Joo-Hyuk Bang;Seon-Young Lim;Yong-Sang Lee;Keun-Woo Lee;Sung-Yong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.104-112
    • /
    • 2024
  • When teeth are extracted, patient face social, psychological and aesthetic problems which can be minimized by fabricating a interim immediate denture. Interim immediate denture manufactured using digital technology can be completed with reduced number of patients' visits and simple laboratory process. Implant-supported removable partial denture (ISRPD) has been suggested as alternative treatment option when fixed implant prosthesis is not feasible. In this case, interim immediate dentures were fabricated using digital technology for patient after teeth extraction and treatment using ISRPD by installing implants and surveyed crowns is found to be successful with better support, stability and maintenance of removable partial dentures.

Evaluation of Salivary Cariogenic Factors in the 6th Grade Children of the Primary School (국민학교 6학년 아동의 치아우식 발생에 미치는 타액성 요인 분석)

  • Park, Myung-Ho
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.151-157
    • /
    • 1988
  • For the detection of the active cariogenic factors contributing to caries development, some practical methods such as the Snyder test, estimation of salivary flow rate and salivary buffering capacity test were evaluated statistically by comparing DMFT and DMFS indexes. Total 122 children (62 male and 60 female ; 64 rural and 58 urban) were selected ramdomly from the 6th grade of the primary school and their salivary cariogenic factors were analysed and evaluated. Among the total 122 children, 78.7% was positive in the snyder test in which the marked, moderate and slight caries activities were 29.5%, 30.3% and 18.9%, respectively. In the Snyder test, 74.45% was positive in urban children while 84.48% was positive in rural children. DMFT and DMFS indexes were markedly lower in negative group than positive group of the Snyder test (p<0.01). The mean and standard deviation of stimulated salivary flow rate was 6.97$\pm$2.57 in male and 6.34$\pm$2.54 in female but no significant difference was observed in sexuality. The stimulated salivary flow rate of urban children was slightly higher that of rural but there was no significant difference between them. However, the group that showed below average in the stimulated salivary flow rate was markedly higher in DMFI and DMFT indexes than the group of above average. The mean and standard deviation of stimulated salivary buffering capacity was 7.65$\pm$2.19 in male and 6.80$\pm$1.67 in female. This difference was significant statistically(p<0.05). Stimulated salivary buffering capacity of urban children was higher than that of rural. Increases in stimulated salivary flow rate and buffering capacity had reduced the onset of dental caries of 14-year-old permanent tooth.

  • PDF

Generation of a transgenic mouse model to study cranial suture development; Apert syndrome (두개봉합 발육 연구를 위한 형질변환 쥐의 개발 : 어퍼트 신드롬)

  • Lee, Kee-Joon;Ratisoontorn, Chootima;Baik, Hyoung-Seon;Park, Young-Chel;Park, Kwang-Kyun;Nah, Hyun-Duck
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.485-497
    • /
    • 2003
  • The form and function of the craniofacial structure critically depend on genetic information. With recent advances in the molecular technology, genes that are important for normal growth and morphogenesis of the craniofacial skeleton are being rapidly uncovered, shaping up modem craniofacial biology. One of them is fibroblast growth factor receptor 2 (FGFR2). Specific point mutations in the. FGFR2 gene have been linked to Apert syndrome, which is characterized by premature closure of cranial sutures and craniofacial anomalies as well as limb deformities. To study pathogenic mechanisms underlying craniosynostosis phenotype of Apert syndrome, we used a transgenic approach; an FGFR2 minigene construct containing an Apert mutation (a point mutation that substitute proline at the position 253 to arginine; P253R) was introduced into fertilized mouse germ cells by DNA microinjection. The injected cells were then allowed to develop into transgenic mice. We used a bone-specific promoter (a DNA fragment from the type I collagen gene) to confine the expression of mutant FGFR2 gene to the bone tissue, and asked whether expression of mutant FGFR2 in bone is sufficient to cause the craniosynostosis phenotype in mice. Initial characterization of these mice shows prematurely closed cranial sutures with facial deformities expected from Apert patients. We also demonstrate that the transgene produces mutant FGFR2 protein with increased functional activities. Having this useful mouse model, we now can ask questions regarding the role of FGFR2 in normal and abnormal development of cranial bones and sutures.

Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites (Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구)

  • Na, Kyoung-Hee;Lee, Kyu-Bok;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.145-155
    • /
    • 2002
  • The results of the present feasibility study are summarized as follows, 1. The three unit bridge of knitted material and UD fibre reinforcement has both the rigidity and the strength against a vertical occlusal load of 75N. 2. Stress concentration at the junctional area between the bridge and the abutments, i.e. between the pontic and the knitted caps was observed. In the case of the bridge with reinforcement straps, it was partly shown that the concentration problem could be improved by simply increasing the fillet size at the area. Further refining in the surface of the junctional area will be needed to ensure a further improvement in the stress distribution. This will require some trade off in the level of the stress and the available space. A parametric study will help to decide the appropriate size of the fillet. 3. Design refinement is a must to improve the stress distribution and realize the most favourable shape in terms of fabrication. The current straight bar with a constant cross section area can be redesigned to a tapered shape. The curve from the dental arch should also be placed on the pontic design. In accordance with design refinement, the resistance of the bridge frame to other load cases should be evaluated. 4. Although not included in the present feasibility study, it is estimated that bridges of the anterior teeth can be made strong enough with the knitted material without further reinforcement using unidirectional materials. In this regard, a feasibility study on design concepts and stress analysis for 3, 4, 5 unit bridge is suggested. 5. Two types of bridge were analysed in terms of fatigue. The safe life design concept, i.e. fatigue design concept, looks reasonable for the bridge where if cracks should form and propagate there is virtually nothing a dentist to do. The bridge must be designed so that no crack will be initiated during the life span. In the case of crowns, however, if constructed with composite resin with knitted materials, it might be possible to repair them, which in general is impossible for crowns of PFM or of metal. Therefore for composite resin crowns, a damage tolerance design concept can be applied and reasonably higher operational stresses can be allowed. In this case, of course, a periodic inspection program should be established in parallel. 6. Parts of future works in terms of structural viewpoint which need to be addressed are summarized as the following: 1) To develop processing technology to accommodate design concepts; 2) More realistic modelling of the bridge and analysis-geometry and loading condition. Thickness variation in the knitted material, taper in the pontic, design for anterior tooth bridge, the effect of combined loads, etc, will need to be included; 3) To develop appropriate design concepts and design goals for the fibre composite FPD aiming at taking the best advantage of knitted materials, including the damage tolerance design concept; 4) To develop testing method and perform test such as static ultimate load test, fatigue test, repair test, etc, as necessary.

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

Fluorine-releasing of Dental Restoration Materials in which the Fluorine is Contained (불소 유리로 본 불소 함유 수복재)

  • Kim, Joo-Won
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.311-322
    • /
    • 2012
  • Restoration materials used to investigate effects of fluorine such as enamel strengthening and anti-caries effects in several types of dental restoration materials were five kinds including Ionoseal(VOCO GmbH, Cuxhaven, Germany), Fuji Filling LC(GC Co. Tokyo, Japan), Quadrant Universal LC(CAVEX Holland BV, Netherlands), PermaCem$^{(R)}$(DMG, Hamburg, Germany) and Dyract$^{(R)}$ AP(Dentsply GmbH, Germany), and the amount of fluorine-releasing was measured with ICS-5000 Reagent-FreeTM Ion Chromatography(RFICTM, Dionex, U.S.A.). The results of this study are as follows. 1. In all types of restoration materials, the amount of fluoride-releasing was reduced with time passage and it was declined sharply to show significance in four weeks. Fuji Filling LC(12.445PPM) or resin-reinforced glass ionomer and PermaCem$^{(R)}$(16.121PPM) or compomer were found to release fluorine for a long term(P<.001). 2. Ionoseal(0.887PPM) or glass ionomer and Quadrant Universal LC(0.957PPM) or composite resin released a few fluorine of 1PPM or less than 1PPM after one week, and Dyract$^{(R)}$ AP or compomer released fluorine of 8.631PPM in one week and its amount of releasing decreased dramatically in two and four week by recording 0.175PPM and 0.116PPM, respectively. Therefore, the effect of releasing fluorine in four weeks was observed to be poor (P<.001). 3. Fuji Filling LC or resin-reinforced glass ionomer and PermaCem$^{(R)}$ or compomer released fluorine of 33.372 and 1.902PPM, respectively in one week and their amount of releasing increased to be 36.371 and 18.223PPM, respectively in two weeks. So, their amount of fluorine-releasing recorded the highest levels in two weeks(P<.001).

Influence of the accuracy of abutment tooth preparation on the marginal adaptation of Co-Cr alloy copings fabricated with a selective laser sintering technology (지대치삭제의정확도가레이져신터링기술로제작된Co-Cr 코핑의변연적합도에미치는영향)

  • Kim, Seo-Rahng;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.337-344
    • /
    • 2015
  • Purpose: The purpose of present study is to examine the correlation between the accuracy of abutment preparation and the marginal adaptation of metal coping. With this view, this study compared the correlations regard to the three different manufacturing methods of selective laser sintering technique, milling and casting. Materials and methods: Two master models were made in a different way. First model with deep chamfer margin was prepared directly by a general clinician and the second model was designed by 3-D designing software program with the same abutment preparation principle and produced by computer aided manufacturing. 12 Co-Cr alloy copings were produced respectively with three different method; SLS system, CAD/CAM milling and conventional lost wax technique from each master model. The total 72 copings fully sit on the master model were stereoscopically evaluated at 40 points along the entire circumferential margin. Results: Significant differences in the absolute marginal discrepancies of Co- Cr copings from SLS system (P=.0231) and casting method (P<.0001) were shown between hand preparation model and computer designed model. However, no significant difference was found between the two model groups from milling method (P=.9962). Conclusion: Within the limitation of this study, the effect of the accuracy of abutment preparation on the marginal adaptation of Co-Cr coping is statistically significant in SLS system and casting group. The copings produced by SLS system exhibited the lowest marginal discrepancies among all groups, and the marginal gap of this method group was influenced by the accuracy of the abutment preparation.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

A Study on the Activation of Industry-University Cooperation -Performance of the Industry-University Cooperation- (대학과 기업간의 산학협력 활성화 방안에 관한 연구 -산학협력 성과를 중심으로-)

  • Jung, Hyo-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2023-2028
    • /
    • 2014
  • The main purpose of this study is to explore the factors related to the performance of industry-university cooperation and determine methods for improving activation of industry-university cooperation. The data was collected by questionnaire survey mailed to the participating researcher and university professors which executed the university-industry cooperation projects. We determined cronbach Alpha Coefficient, pearson's correlation coefficient and multiple regression analysis. According to multiple regression analysis, reflect of mutual needs and local industry construction have statistically significant relationships with general satisfaction of university. Knowledge and working ability of industry-university cooperation, activeness of industry-university cooperation activity, Local economy scale and local industry construction have statistically significant relationships with general satisfaction of industry. In relation continuity, activeness of industry-university cooperation activity and information exchange have statistically significant relationships with relation continuity of university. Knowledge and working ability of industry-university cooperation and activeness of industry-university cooperation activity have statistically significant relationships with relation continuity of industry. In outcome utilization, knowledge and working ability of industry-university cooperation, research establishment and apparatus have statistically significant relationships with outcome utlization of university. In conclusion, capability factors, cooperative factors, political factors and external environment factors affected industry-universiry cooperation. Knowledge and working ability of industry-university cooperation will be able to upgrade on general satisfaction, relation continuity and outcome utilization.