• Title/Summary/Keyword: data-acquisition system

Search Result 2,083, Processing Time 0.031 seconds

Accuracy Assessment of Mobile Mapping System

  • Manandhar, Dinesh;Shibasaki, Ryosuke
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1152-1154
    • /
    • 2003
  • The needs of 3-D data have been increasing for various applications like visualization, 3-D modeling, planning and management as well as entertainment. Mobile mapping has become a quick and practical means for acquiring necessary 3-D data for above-mentioned applications. A mobile mapping system mainly consists of two main components, viz. data acquisition devices and positioning devices. The data acquisition devices consist of CCD cameras or/and laser scanners. The positioning devices consist of GPS, INS, Odometer (shaft encoder) and some other referencing devices. The overall accuracy of mobile mapping system depends on the accuracy of positioning devices and their integrated output. Though, GPS is the main input device for the position information, the signal is not available for the computation of position all the times in urban area. The GPS satellites are normally obstructed by high-rise buildings. Thus it is very important to understand the accuracy of such a system in different environments and means to solve such problems. We have developed a mobile mapping system called VLMS (Vehicle-borne Laser Mapping System), which consists of CCD Cameras, Laser scanners, GPS, INS and Odometer. In this paper, we will present and discuss the accuracy of this system with data acquired in different environments (open area, urban area, tunnel, express way etc) by analyzing the data with respect to other existing digital data.

  • PDF

Forensic Data Acquisition on Cell Phone using JTAG Interface (JTAG을 이용한 휴대폰 포렌식 데이터 수집)

  • Kim, Keon-Woo;Ryu, Jae-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.333-334
    • /
    • 2008
  • With the role of cell phones in today's society as a digital personal assistant as well as the primary tool for personal communication, it is possible to imagine the involvement of cell phones in almost any type of crime. The progression of a criminal investigation can hinge on vital clues obtained from a cell phone. This paper will be concentrated on CDMA system phones and focus on the data extraction for cell phone forensics. Especially, the data acquisition method of JTAG interface access to memory chip will be covered.

  • PDF

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF

A Cost Estimation Development Methodology via CER's Linear Combination (CER 선형결합을 통한 비용추정 모델 개발)

  • Jung, Won-Il;Lee, Yong-Bok;Kim, Dong-Kyu;Kan, Sung-Jin
    • IE interfaces
    • /
    • v.25 no.3
    • /
    • pp.347-356
    • /
    • 2012
  • The acquisition cost of defense weapon system has been continuously increasing because of art-of-technology of it. This phenomenon requires efficiency and transparency in the weapon system acquisition process through cost estimation. Therefore cost estimation is very important to the government acquisition programs to support decisions about funding and to evaluate resource requirement as a key decision point. The Commercial parametric cost estimating models have been using extensively to obtain appropriate cost estimates in early acquisition phase. These models have many restrictions to ensure the cost estimating result in Korean defense environment because they are developed based on foreign R&D data. Also estimation results are different from Korean defense industry accounting system. So, some studies have been tried to develop a CER (Cost Estimation Relationship) based on the Korean historical data. However, there are some restrictions to improve the predictability and ensure the stability of the developed singular CERs which consider the following data characteristics individually. The the abnormal conditions of data that is multicollinearity, outlier and heteroscedasticity under rack of the number of observations. In this paper, a CER's Linear Combining Model is proposed to overcome those limitations which guarantee more accurate estimation (25.42% higher precision) than other singular CERs. At least, this study is meaningful as a first attempt to improve the predictability of CER with insufficient data. The methodology suggested in this study will be useful to develop a complex Korean version cost estimating model development in future.

Impact Localization Using Piezoelectric Paint Sensor with Mosaic Pattern Electrodes (모자이크 패턴 전극 압전 페인트 센서를 이용한 충격 위치 검출)

  • Kang, Sang-Hyeon;Kang, Lae-Hyong
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.2
    • /
    • pp.19-25
    • /
    • 2019
  • To detect the impact location of a structure, the authors' group conducted a study on piezoelectric paint sensor. The piezoelectric paint sensors are used for impact detection due to their inherent characteristics: sensitivity to high-frequency signal and impact. Additionally, the paint sensor can be applied on curved and complex structures where ceramic sensor would not be applicable. Moreover it is a self-powered sensor therefore no need for an external power source. For impact localization, mosaic pattern electrodes were coated on the specimen and the impact signal obtained from any part of the electrode where the impact occurred. If we more precise impact localization is required, the electrodes should be divided into more parts and impact data acquisition conducted in all the points of the electrode. In this paper, we developed a light, cheap and simple multi-channel data acquisition system to aid in data gathering. In total four channels data acquisition have been tested using the ARM Cortex-M3.

Implementation of high-speed parallel data transfer for MCG signal acquisition (심자도 신호 획득을 위한 고속 병렬 데이터 전송 구현)

  • Lee, Dong-Ha;Yoo, Jae-Tack
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.444-447
    • /
    • 2004
  • A heart diagnosis system adopts hundreds of Superconducting Quantum Interface Device(SQUID) sensors for precision MCG(Magnetocardiogram) or MEG(Magnetoencephalogram) signal acquisitions. This system requires correct and real-time data acquisition from the sensors in a required sampling interval, i.e., 1 mili-second. This paper presents our hardware design and test results, to acquire data from 256 channel analog signal with 1-ksample/sec speed, using 12-bit 8-channel ADC devices, SPI interfaces, parallel interfaces, and 8-bit microprocessors. We chose to implement parallel data transfer between microprocessors as an effective way of achieving such data collection. Our result concludes that the data collection can be done in 250 ${\mu}sec$ time-interval.

  • PDF

Non-contact surface wave testing of pavements: comparing a rolling microphone array with accelerometer measurements

  • Bjurstrom, Henrik;Ryden, Nils;Birgisson, Bjorn
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.1-15
    • /
    • 2016
  • Rayleigh wave velocity along a straight survey line on a concrete plate is measured in order to compare different non-destructive data acquisition techniques. Results from a rolling non-contact data acquisition system using air-coupled microphones are compared to conventional stationary accelerometer results. The results show a good match between the two acquisition techniques. Rolling measurements were found to provide a fast and reliable alternative to stationary system for stiffness determination. However, the non-contact approach is shown to be sensitive to unevenness of the measured surface. Measures to overcome this disadvantage are discussed and demonstrated using both forward and reverse rolling measurements.

A Study on Remote ECG Diagnostic System Using Telephone Line (공중회선망을 이용한 원격 심전도 진단 시스템)

  • Lee, M.H.;Park, S.H.;Kim, Y.M.;Shin, K.S.;Jeong, H.K.;Jeong, K.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.69-78
    • /
    • 1992
  • This Paper describes implementation of a remote ECG diagnostic system using telephone line. The overall system includes ECG data acquisition system, ECG terminal, system control software, automatic diagnosis system, and transmission system.'The proposed system provides various functions, which are ECG data acquisition, transmission, receiving, diagnosis and dialogue between patients and medical doctors. Thls system is very simple and convienient to use. We evaluate the performance of modem and the accuracy of automatic diagnosis algorithm. The obtained results suggest the Possibilities of a remote ECG diagnostic system using the only existed telephone line.

  • PDF

Analysis and Evaluation of 3kW Grid-Connected PV System by Field Demonstration Test (3kW급 계통연계형 태양광발전시스템의 실증시험 분석평가)

  • So, Jeong-Hoon;Yu, Gwon-Jong;Jung, Myung-Woong;Jung, Young-Seok;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1353-1355
    • /
    • 2003
  • Total six units of 3kW photovoltaic (PV) system and data acquisition system (DAS) are constructed for analyzing performance of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data-acquisition system. Furthermore, not only performance test of each PV system component such as PV module and power conditioning system, but also performance of total PV system e.g. system efficiency, electric power and loss factor at the site are reviewed.

  • PDF

The Field Demonstration Study of Residential 3㎾ PV System (3㎾ 태양광발전시스템 실증연구 I)

  • 김형석;박정국;임홍우;조금배;백형래;최창주
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.365-367
    • /
    • 2003
  • Total six units of 3㎾ photovoltaic system and data acquisition system (DAS) are constructed for analyzing performance of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied. operation characteristics of the PV system are collected and analyzed in data-acquisition system furthermore, not only performance test of each PV system component such as PV module and power conditioning system but also performance of total PV system e.g. system efficiency power and loss factor at the site are reviewed.

  • PDF