• Title/Summary/Keyword: damaged building

Search Result 366, Processing Time 0.026 seconds

Seismic Performance Evaluation of Damaged Apartment building (손상된 벽식 아파트 구조의 내진성능평가)

  • 김동영;장극관;서대원;천영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.431-436
    • /
    • 2002
  • The purpose of this study is to evaluate resistance capacity of the damaged wall structural system against earthquake ground accelerations. Two lumped damage models(5 story, 12 story) are investigated by nonlinear time history analysis. As a result of analyses, the effect of stiffness degradation due to structural damages might change the interstorydrift of the structure. Therefore the increasing interstorydrift of damaged structures might be applied to evaluate the seismic performance of damaged structures.

  • PDF

Estimation of Optimum Maintenance Cycle for the Chloride Damaged RC Structure (염해를 입은 RC 구조물의 최적 보수주기 산정 기법에 관한 연구)

  • Yun, Sun-Young;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.235-236
    • /
    • 2010
  • Since many structures in the sea environment are damaged by chloride, appropriate repair strategy is required. Therefore in the paper, optimum period for the RC structure's repair is calculated with consideration of economic efficiency. Moreover, when the concrete members are repaired with the other material such as polymer mortar forr section restoration, their expected service life also calculated to predict more accurate repair period during the life span.

  • PDF

Numerical Study on the Fire Damaged Reinforced Concrete Building Structures Considering Influencing Fire Case and Parameters of Columns (화재피해를 받은 철근콘크리트 건축물의 기둥의 영향인자를 고려한 해석적 연구)

  • Suh, Yeonwoo;Son, Hee Ju
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.101-112
    • /
    • 2022
  • Expanding urbanization practices result in high numbers of buildings being developed in city centers. This high building concentration leads to an increased fire risk, resulting in higher casualty rates and increased economic damages compared to fires in the past. The purpose of this study was to analyze the structural behavior of fire-damaged reinforced concrete buildings using analytical methods and to suggest methods of improving fire resistance in the event of a fire. Damage levels were measured using commercial software to apply the finite element method, ABAQUS, and MIDAS GEN to the dataset. Load-deflection curves were calculated using the effective area and moment of inertia of the fire-damaged columns provided by ABAQUS. The results of this analysis indicate that fire-damaged beams with experience greater deflection from indoor fires than they will from outdoor fires. Fires that occurred on the middle floors were more dangerous than those occurring on higher floors, and eccentrically loaded columns experienced more damage than axially loaded columns. The results indicate that these methods accurately predict structural behaviors of fire damaged concrete columns by considering fire exposure area and eccentric loading.

Study on Integrity Assessment of Pile Foundation Based on Seismic Observation Records

  • KASHIWA, Hisatoshi
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.369-376
    • /
    • 2020
  • Given the importance of quickly recovering livelihoods and economic activity after an earthquake, the seismic performance of the pile foundation is becoming more critical than before. In order to promote seismic retrofit of the pile foundations, it is necessary to develop a method for evaluating the seismic performance of the pile foundation based on the experimental data. In this paper, we focus on the building that was suffered severe damage to the pile foundation, conduct simulation analyses of the building, and report the results of evaluating the dynamic characteristics when piles are damaged using a system identification method. As a result, an analysis model that can accurately simulate the behavior of the damaged building during an earthquake was constructed, and it was shown that the system identification method could extract dynamic characteristics that may damage piles.

The Standardized Methods for Improvement of Maintenance Deterioration caused by Fire damage (국제 표준화를 위한 화재이후의 유지관리 시스템 개발)

  • Kwon, Young-Jin;Koo, In-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.230-231
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

The Standardized Methods for Improvement of Maintenance and Performance Construction of Deterioration caused by Fire damage (화재피해 콘크리트의 유지관리 및 시공성능 향상을 위한 표준화방안)

  • Seo, Dong-Goo;Kim, Dong-Eun;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.16-18
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

Masonry building behaviors during the February 6-12, 2017 Ayvacik-Çanakkale Earthquakes

  • Ural, Ali
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2019
  • Masonry structures in the rural areas of Turkey often damaged due to moderate and big earthquakes. After every earthquake many scientists made field investigations on the earthquake performance of these structures and gave many useful information on construction techniques. However, the newly constructed masonry buildings are still not suitable for the suggested techniques, and they are still in danger against future earthquakes. Five moderate earthquakes of moment magnitude Mw 5.3, 5.3, 5.2, 5.0, and 5.3 struck the Ayvacik-Çanakkale District of Turkey between 6 and 12 February, 2017. More than a thousand of aftershocks were occurred and most of the masonry buildings in the villages nearby main shock epicenter were affected. The author went to the earthquake field and investigated the earthquake performances of masonry structures. This paper presents the recorded acceleration data, acceleration response spectra, and the seismological aspects of these earthquakes. Besides, case studies of damaged stone masonry buildings, and failure mechanisms are discussed with illustrated photos which were taken during the field investigations. It is concluded that the damaged masonry buildings were not designed and constructed properly in accordance with the Turkish building codes or similar specifications.

Study on Damage of Column of Wooden Traditional Building by Insects (곤충에 의한 목조 고 건축물 기둥의 손상에 대한 연구)

  • Kim, Gwang-Chul;Jeong, In-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.69-76
    • /
    • 2003
  • Front columns of buildings were most severely damaged by insects. Hole diameter damaged by insects were different in each location on columns, that is, bottom, middle position, or top of columns. That mean various insects attacked on columns of wooden traditional buildings because kinds of each insect depends on the hole diameter. Specially, middle position of columns were harmed seriously. Hole diameters damaged by insects were various from 1 mm to 10 mm, but approximately 5 mm diameter was found most commonly.

Asessment of Fire Damage Depth of 21MPa-class Concrete Using Thermogravimetric Analysis (열중량분석을 활용한 21MPa급 콘크리트의 화해피해깊이 진단방법 분석)

  • Lim, Gun Su;Han, Soo Hwan;Han, Jun Hui;Yoon, Chee Whan;Han, Min Cheol;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.243-244
    • /
    • 2021
  • In this study, we develop diagnostic technology for damage depth of fire-damaged concrete and propose methods for damage caused by fire by drying damaged concrete after immersion. As a result of the test, the damaged depth was clearly found when evaluating the depth of impurities caused by fire in a drying method after water had permeated, and it could be verified using thermogravimetric analysis.

  • PDF

Comparison of the Compressive Strength between Damaged Part due to Early Frost Damage and Sound Part of the Concrete in Winter (동절기 타설 콘크리트의 초기동해 피해부위와 건전부위 압축강도 발현 특성 비교)

  • Choi, Yoon-Ho;Kim, Sang-Min;Park, Byoung-Joo;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.98-99
    • /
    • 2020
  • The objective of the study is to investigate the compressive strength of damaged part by early frost damage and sound part of the concrete placed when exposed to a low temperature of -20℃ for 24 hours in normal concrete. Test results indicated that the compressive strength of damaged part was 14.5 MPa lower than that of sounf part due to early frost damage.

  • PDF