• 제목/요약/키워드: damage condition

Search Result 2,006, Processing Time 0.028 seconds

Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS (3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법)

  • Lee, K.O.;Jung, Y.S.;So, J.H.;Yu, B.G.;Yu, G.J.;Choi, J.Y.;Choy, I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

A Study on Safety Assessment for Ship Sailing under Electric Power Cable (해월(海越)송전선 하부의 선박 통항 안전성 평가에 관한 연구)

  • Kim, Hyun-Jong;Hong, Tae-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.1 s.28
    • /
    • pp.55-60
    • /
    • 2007
  • Many electric power cables span the sea in Korean archipelago. Lots of shipping routes were established between the islands in the same area and ships frequently sail under the cable which cross the seas. Sometimes electric power cables were accidently broken by sailing ships and catastrophic damage of island industry followed thereby. If navigators have detailed knowledge about the height of electric power cable, the ship's sailing condition will be greatly improved. But at the present time, navigators have limited data about the electric power cable. Those are the horizontal distance between pylons, the height of pylons and minimum height of electric power cable. This study introduced the calculating methodology to find out the height of cable at any position between pylons. The ship's tracks were recorded and traffic safety was assessed by statistical method in relation to cable height.

  • PDF

Reconstruction of a long defect of the median nerve with a free nerve conduit flap

  • Campodonico, Andrea;Pangrazi, Pier Paolo;De Francesco, Francesco;Riccio, Michele
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.187-193
    • /
    • 2020
  • Upper limb nerve damage is a common condition, and evidence suggests that functional recovery may be limited following peripheral nerve repair in cases of delayed reconstruction or reconstruction of long nerve defects. A 26-year-old man presented with traumatic injury from a wide, blunt wound of the right forearm caused by broken glass, with soft tissue loss, complete transection of the radial and ulnar arteries, and a large median nerve gap. The patient underwent debridement and subsequent surgery with a microsurgical free radial fasciocutaneous flap to provide a direct blood supply to the hand; the cephalic vein within the flap was employed as a venous vascularized chamber to wrap the sural nerve graft and to repair the wide gap (14 cm) in the median nerve. During the postoperative period, the patient followed an intensive rehabilitation program and was monitored for functional performance over 5 years of follow-up. Our assessment demonstrated skin tropism and sufficient muscle power to act against strong resistance (M5) in the muscles previously affected by paralysis, as well as a good localization of stimuli in the median nerve region and an imperfect recovery of two-point discrimination (S3+). We propose a novel and efficient procedure to repair >10-cm peripheral nerve gap injuries related to upper limb trauma.

Analysis of a damaged industrial hall subjected to the effects of fire

  • Kmet, Stanislav;Tomko, Michal;Demjan, Ivo;Pesek, Ladislav;Priganc, Sergej
    • Structural Engineering and Mechanics
    • /
    • v.58 no.5
    • /
    • pp.757-781
    • /
    • 2016
  • The results of diagnostics and analysis of an industrial hall located on the premises of a thermal power plant severely damaged by fire are presented in the paper. The comprehensive failure-related diagnostics, non-destructive and destructive tests of steel and concrete materials, geodetic surveying of selected structural members, numerical modelling, static analysis and reliability assessment were focused on two basic goals: The determination of the current technical condition of the load bearing structure and the assessment of its post fire resistance as well as assessing the degree of damage and subsequent design of reconstruction measures and arrangements which would enable the safe and reliable use of the building. The current mechanical properties of the steel material obtained from the tests and measured geometric characteristics of the structural members with imperfections were employed in finite element models to study the post-fire behaviour of the structure. In order to compare the behaviour of the numerically modelled steel roof truss, subjected to the effects of fire, with the real post-fire response of the damaged structure theoretically obtained resistance, critical temperature and the time at which the structure no longer meets the required reliability criteria under its given loading are compared with real values. A very good agreement between the simulated results and real characteristics of the structure after the fire was observed.

The kinematics of breast displacement by the treadmill activity levels (트레드밀 운동 속도에 따른 유방의 운동학적 변화 연구)

  • Jang, Yumi;Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.2
    • /
    • pp.290-299
    • /
    • 2014
  • This research sought to analyze the characteristics of breast movement at the treadmill activity levels. It also examined the effect of wearing a sports bra in reducing breast displacement. The subjects for the data collection were females in their 20s (n=2) with C-cup size breast. The experimental conditions were three different moving speeds (4 km/h, jogging: 7 km/h, and sprinting: 10 km/h) and two types of sports bras. Three dimensional breast displacement was measured. The displacement of the right nipple point was measured with a 3D motion analyzer. The results show that the breasts were greatly displaced from the walking speed (4 km/h) when subjects did not wear any bra. Whereas their breast displacement distance decreased remarkably when they wore sports bras. The nipple point moved 42~44 mm in the vertical direction at walking speed with naked condition. But it was reduced by 80% after wearing sports bras. When subjects running (7 km/h, 10 km/h) without any bra, the nipple point moved 122~141 mm. However it was reduced by 60~70% when they wore sports bras. The apartment time (time delay) between at the highest point of the upper body and the nipple was 0.25 seconds at the running speeds (7 km/h, 10 km/h) without wearing any bra. After wearing sports bras, the time delay was cut to 0.06~0.12 seconds. These results implies that without wearing any bra the skin surrounding the breasts might be seriously pulled at running activity. The functional sports bra suppress breast movement. It might prevent the sagging of breasts by preventing the damage of the Cooper's ligaments.

Study on a Standardized Rockfall-Protection Fence for Various Rockfall Impact Energy using Finite Element Analysis (유한요소해석을 이용한 다양한 낙석 충돌에너지에 대한 표준 낙석방지울타리 형식 제시 연구)

  • Park, Hyungon;Jang, Hyunick;Kim, Bumjoo;Moon, Jiho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.5
    • /
    • pp.297-302
    • /
    • 2020
  • Korea has many mountainous regions, and slope collapse that can lead to damage in road facilities and loss of lives often occurs. Rockfall-protection facilities are necessary to reduce such damages. Among these facilities, the standard Korean rockfall-protection fence is designed to resist 50 kJ of rockfall impact energy. However, the range of rockfall energy significantly varies depending on the condition of the slope, and it sometimes reaches up to 100 kJ. Thus, providing several types of standardized rockfall-protection fence is necessary to address the different rockfall impact energy for efficient response to rockfalls. This paper presents a study on standardized rockfall-protection fence for various rockfall impact energy using finite-element analysis. According to the results, standardized rockfall-protection fences against rockfall impact energy of 30 and 100 kJ were proposed and have been verified.

Dry Etching of GaAs in a Planar Inductively Coupled BCl3 Plasma (BCl3 평판형 유도결합 플라즈마를 이용한 GaAs 건식식각)

  • Lim, Wan-tea;Baek, In-kyoo;Jung, Pil-gu;Lee, Je-won;Cho, Guan-Sik;Lee, Joo-In;Cho, Kuk-San;Pearton, S.J.
    • Korean Journal of Materials Research
    • /
    • v.13 no.4
    • /
    • pp.266-270
    • /
    • 2003
  • We studied BCl$_3$ dry etching of GaAs in a planar inductively coupled plasma system. The investigated process parameters were planar ICP source power, chamber pressure, RIE chuck power and gas flow rate. The ICP source power was varied from 0 to 500 W. Chamber pressure, RIE chuck power and gas flow rate were controlled from 5 to 15 mTorr, 0 to 150 W and 10 to 40 sccm, respectively. We found that a process condition at 20 sccm $BCl_3$ 300 W ICP, 100 W RIE and 7.5 mTorr chamber pressure gave an excellent etch result. The etched GaAs feature depicted extremely smooth surface (RMS roughness < 1 nm), vertical sidewall, relatively fast etch rate (> $3000\AA$/min) and good selectivity to a photoresist (> 3 : 1). XPS study indicated a very clean surface of the material after dry etching of GaAs. We also noticed that our planar ICP source was successfully ignited both with and without RIE chuck power, which was generally not the case with a typical cylindrical ICP source, where assistance of RIE chuck power was required for turning on a plasma and maintaining it. It demonstrated that the planar ICP source could be a very versatile tool for advanced dry etching of damage-sensitive compound semiconductors.

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

A Study on the Seller's Obligation of Conformity of Transport Documents in Shipment Sales under CISG - Focused on Bill of Lading (해상송부매매에서 국제매매협약상 매도인의 서류적합의무에 관한 일고찰 - 선하증권을 중심으로 -)

  • Hur, Hai-Kwan
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.37
    • /
    • pp.61-85
    • /
    • 2008
  • Bills of lading are crucial in international sales on shipment terms since they guard buyers against loss of or damage to the goods in transit by giving them the rights against carriers. A bill of lading, as document of title, gives the buyer the right to demand physical possession of the goods from the carrier and enables the buyer who is in possession of damaged or short-delivered goods to sue the carrier. In this context the buyer in sales on CIF or CFR terms or FOB terms with additional services benefits from the bill of lading which functions as a receipt of goods and a evidence of the terms of the contract of carriage. Protection of such buyer's interests can be provided in the sale contract through appropriate express or implied terms on the seller's documentary obligations: Which transport document, a bill of lading or a sea waybill, is required? Who should be named as the consignee in the transport document and, in case of bill of lading, by whom should the bill be endorsed? What should be stated in the bill of lading for the quantity of the goods? How about a bill of lading that contains so called "unknown clause"? How many bills of lading for the entire contract goods should be tendered? Can a bill of lading stating that the goods have been shipped in apparent good order and condition also state that the goods were damaged after shipment? This paper seeks to provide answers for these particular questions.

  • PDF

A Study on the Hydroulic Phenomenon at the Douvstream Channel of the Drainage Sluice (배수갑문 물받이의 수리현상에 관한 연구)

  • 이희영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.4
    • /
    • pp.4218-4225
    • /
    • 1976
  • To insure the safety of the drainage sluice, topogrophical change due to erosion as well as capability of discharging the design flow in a very important factor. In consideration of the fact that the drainage sluice is built in the sea, its construction has many topographically restricted problems and naturally requires a completeness of research and experiment. This thesis is a comparative and analytic study of discharging flow acting on the erosion at the bottom of the structure on the basis of the measured velocity on the downstream channel of the drainage sluice. (1) The measured velocity shows a little higher values than the computed velocity, because the measured velocity was observed at the surface of the stream. There fore, it is reasonable that the compated velocity should be taken in this study. (2) The field observation was conducted to have the measurement of the flow velocity without surveying the area of flow. Therefore, the coefficient of discharge could not be computed. The survey of the area of flow is planned to be conducted along with the measurement of the flow velocity. (3) The apron of the drainage sluice is free discharging type and it was designed to be about 80m in length less than it should be. (4) The apron of free flow discharging type should have a solid foundation to protect the structure by preventing erosion damage to upstream and downstream channels against weathering of rock and strong torrent. Whether free flow discharging type or energy-dissipating type is best chosen depends on the topographical condition of the forage site, therefore, there would be a comparative study before the final decision was made about the protrection for the structure. (5) It is considered to be appropriate that the design and construction of the drainage sluice should have a complete study which is based on hydraulie model test before the type of protection is decided. (6) It is much requested that a variety of experiment equipments be installed and observed to study the protection for the drainage sluice.

  • PDF