• 제목/요약/키워드: curtain-wall

검색결과 239건 처리시간 0.028초

비정형 파사드의 유닛 모듈 시공 공법 개발 (Unit Module Construction Method for Freeform Facade)

  • 김성진;박성진;박영미;류한국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.220-221
    • /
    • 2013
  • Exterior walls are designed and constructed through design focused exterior wall system. Nowadays, freeform facade design has been changing according to material, form and function of the exterior wall system. Especially, curtain wall facade system is designed and manufactured using solar shading faces. However, the traditional method have a lot of difficulties in the currently performing technology for curtain wall facade. It is important to make the freeform facade components that integrated as a surface of freeform buildings. Therefore it is necessary to develop unit module construction method for freeform facade.

  • PDF

구조용 실링마감재의 내환경 조건에 따른 탄성복원 특성 연구 (A Study on the Elastic Restoration Characteristics According to Environmental Resistance Condition of Structural Sealing Finishing Materials)

  • 장필성;강동원;홍순구;김영근;김성래
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.6-12
    • /
    • 2018
  • 본 최근 건축물 외벽공사에 커튼월 공법의 사용이 증가하고 있다. 외벽 커튼월 공법은 공기단축 및 경제적 효용이 크다는 장점으로 인해 건물의 외벽으로도 널리 시공되고 있다. 그러나, 커튼월 공법의 프레임과 유리를 연결해 주는 구조용 실란트에 대한 내후성 및 구조물의 거동에 대한 열화를 대체한 시험은 KS F 4910 규격에는 부재한 실정으로 안정적인 커튼월 공법 도입과 품질향상을 위해서는 필요한 요소이다. 본 연구에서는 외기환경하에서 거동에 대한 탄성복원력시험을 실시하였다. 구조용 실란트를 대상으로 열에 대한 실링재의 열화를 평가하였다. 국내에서는 구조용 실란트의 가변형 변위거동에 대한 연구는 부족한 실정으로 본 연구에서는 외기 환경에 노출된 열화조건을 대체하여 실험실 조건에서 재현한 결과를 확인하고, 설계에 반영하고자 한다. 본 연구 결과에 따르면, 기존의 구조용 실링재는 KS F 4910의 품질기준은 만족하지만, 본 연구에서 실시한 조건에서는 시험체의 파단과 표면의 균열 등이 발생하는 것을 확인하였다. 특히, 내후성 시험에서는 시험체 모두 불용의 상태를 확인하여 향후, 커튼월 공법에 사용되는 구조용 실링재의 장기적인 내구성능 평가가 필요한 것으로 판단된다. 따라서, 기존의 구조용 실링재가 현장에 적용되기 위해서는 별도의 내구성능 평가를 실시가 요구된다.

커튼월 고층 건물 빛 반사에 의한 운전자 눈부심 가능성 (A Case Study on the Driver's Glare Hazard Assessment by Light Reflection of Curtain Wall Type Buildings)

  • 송형준;서영교
    • 한국안전학회지
    • /
    • 제36권2호
    • /
    • pp.26-31
    • /
    • 2021
  • Buildings with glass curtain walls have become popular due to their appealing aesthetics and ability to let in natural light. However, light reflection from the glass surface is unavoidable in these buildings. In particular, the reflection of light from the glass envelope can create afterimage glare, a hazard to nearby drivers and pedestrians. Despite this potential danger, glare from buildings with curtain walls has not been well-studied. Hence, we analyzed the effect of light reflection on glare around a glass-enclosed skyscraper, depending on its surface reflectance. We investigated the potential hazard of glare to drivers using a commercially available software program. The results indicate that the direction of light reflection is distinctive when the incident angle of solar light increases. Moreover, this light reflection is high enough to induce an afterimage to drivers and pedestrians near the building. We found that keeping the reflectance of the building surface under 3% is required to minimize the afterimage hazard to drivers. Consequently, we recommend managing glass reflectance and installing additional traffic safety systems to reduce traffic accidents near curtain wall buildings.

초고층 커튼월 공정관리 최적화를 위한 건설성능 데이터 표준화 (Data Standardization of Construction Performance for Optimized Process Management in High-rise Curtain-wall Operations)

  • 이태희;고용호;김영석;한승우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.283-284
    • /
    • 2012
  • High-rise building construction has been increasing for the recent years and the construction process has become more complicated. This suggests a need for precise planning based on reliable data to prevent cost overruns and delays. However, the process planning is implemented based mainly on the experience of engineers that can result in critical damage in cost and time. Accurate productivity estimation and unit cost analysis must be considered important matter to prevent such disaster. This study estimates productivity and unit cost of curtain wall operations in high-rise building construction by simulation techniques and statistical methodologies. This study suggests a decision making methodology for the site personnel that enables to compare various combinations of productivity and unit cost based on reliable data that has been collected in actual construction sites. It is expected that this study contributes to the following research of developing an optimized construction performance assembling model for the site personnel.

  • PDF

경량기포콘크리트(ALC) 패널을 건축물 외장 커튼월에 적용을 위한 도료의 기초적 연구 (Applications and Analysis of Exterior Paints for the Curtain Wall Panel System based on the Autoclaved Lightweight Concrete(ALC))

  • 이용수;라현주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권3호
    • /
    • pp.59-66
    • /
    • 2012
  • Autoclaved Lightweight Concrete(ALC) features such as a high performance insulation, the fire resistance, the advantage of easy handing construction, and lightweight panels applied the curtain wall system. ALC materials are certified as non-toxic environmental and eco-friendly productions. But ALC external panels mixed with blast furnace slag pounder and silica fume have to be coated with a stucco compound or plaster because of resisting the ambient environment. This study is that mixing tests to evaluate a performance analysis of exterior paints to be make-up pigments(organic or inorganic) coated with panel surface. Testing compared by KS F 2476; flow test, KS F 2426; compression strength test, KS F 2762; bond strength test. In results, the case of the inorganic binder, ratio of alumina cement : anhydrite is 90:10 to 80:20 at the highest level of intensity. In the case of the organic binder, adhesive strength rating at surface of ALC, the pullout strength is below 0.5 $N/mm^2$ but the normal concrete is over 2.0$N/mm^2$. A contents ratio of EVA resin is more than 3% and then bond strength is effectively.

커튼월 사무소용 건물에서 실내발열이 냉난방 부하에 미치는 영향 (The Impact of Internal heat gain on heating and Cooling Load in Curtain Wall Office Buildings)

  • 김정윤;육인수;남현진;이진성;김재민;조수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.925-930
    • /
    • 2008
  • As office automation appliances and communication equipments are adopted in office buildings, internal heat gains increase gradually. When making simulation model, internal heat gains are usually set up with standard values or ignored. Therefore, the impact of the internal heat gains has been ignored or not been focused although it is recognised as significant contributor to heating/cooling load of buildings. This study focused on the impact of internal heat gains on curtain wall buildings. the amount and schedules of heat internal gains profiles not only affect the profiles of heating/cooling loads, but also make impact on reducing the effectiveness of high performance glazing systems. It is important to identify internal heat gains profiles before considering the installation of high performance glazing systems.

  • PDF

수치모형에 의한 토양증기추출법의 제거효율에 관한 연구 - 차단벽, 추출유량, 펌프가동방법의 영향 - (A Study on the Removal Efficiency of the Soil Vapor Extraction by Numerical Simulation)

  • 이창수
    • 한국수자원학회논문집
    • /
    • 제32권2호
    • /
    • pp.121-129
    • /
    • 1999
  • 본 연구는 토양 및 지하수 오염의 정화방법으로써 토양증기 추출법을 이용할 경우, 이의 효율적 운용을 위하여 추출공 주변에 차단벽을 설치할 경우, 추출펌프유량의 크기 및 펌프가동의 형태 등이 제거효율에 미치는 영향을 평가하기 위하여 수치해석을 이용하여 검토하였다. 그 결과 추출공 주위에 차단벽을 설치할 경우 및 추출펌프의 운용을 단속적으로 실시하였을 경우, 추출공 주변에 고농도의 가스분포를 밀집시킴으로 인해 고농도의 가스를 제거할 수 있게 되어 제거율이 상승하였다. 추출유량의 크기변화가 TCE가스의 제거율에 미치는 영향을 추출유량이 클수록 상승하지만 TCE가스의 정화효율은 추출유량의 크기에는 의존하지 않는다는 것을 알 수 있었다.

  • PDF

구획화재 시 국부복사열에 노출된 유리면의 수막접촉에 따른 급냉파열특성 관한 실험적 연구 (Experimental Study on Interaction of Water Sprayed Curtain on Hot Surface of a Window Glass and its Effects on Glass Surface Temperature in Room Fires)

  • 박형주;지남용
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.124-130
    • /
    • 2003
  • 본 연구는 방화구획에 적용 가능한 수막형성유리벽에의 직근에 화원이 위치하는 경우 국부복사열에 의해 수막형성전 유리면이 가열된 상태에서 상부 수막분사노즐에서 분사되는 수막이 접촉함에 따른 급냉파열현상을 규명하기 위한 연구이다. 유리면 직근에서 국부복사열을 주는 실화재실험을 실시하여 분석하면 보통유리는 유리면 포면온도(가열측)가 $100^{\circ}C$를 넘는 경우에 수막을 접촉시킬 경우 파열이 발생하며, 강화유리는 유리 가열면 온도가 $250^{\circ}C$이상일 때 수막형성에 의한 급냉 파열이 발생함을 알 수 있었다. 향후 강화유리에 수막을 도포시키는 현재 방화구획에 사용되고 있는 유리의 대다수가 강화유리인 것을 감안하면 수막의 도포이전에 강화유리면의 온도가 $300^{\circ}C$이내에서는 수막을 유리면에 급속히 접촉시켜도 유리면의 급냉 파열이 일어나지 않음을 발견하였다. 따라서 일정한 공간구획 내에서 화재발생시 유리면의 직근에 화원이 위치하여 국부적으로 복사열을 가할 경우에도 화원상부 천정면에 설치된 감지시스템에 의해 한계온도이전에 수막형성시스템을 작동시켜 급냉파열현상을 발생시키지 않는다면 수막형성유리벽을 실제 방화구획의 경계벽으로 사용하는데 있어서 예측가능한 장애요인을 제거하는 데 비약적인 공헌을 한 것에 그 의미를 둔다.

저반사구조물을 이용한 파력발전에 있어서 압축공기흐름 및 작용파압에 관한 수치해석 (Numerical Analysis of Pressurized Air Flow and Acting Wave Pressure in the Wave Power Generation System Using the Low-Reflection Structure with Wall-Typed Curtain)

  • 이광호;최현석;김창훈;김도삼;조성
    • 한국해안·해양공학회논문집
    • /
    • 제23권2호
    • /
    • pp.171-181
    • /
    • 2011
  • 최근 생산비용을 절감하고 고밀도의 해양에너지발전시스템을 구축하기 위한 다양한 접근이 시도되고 있다. 본 연구에서는 방재와 파랑에너지의 이용이라는 두 목적을 달성하기 위하여 가장 효율적인 에너지의 변환시스템으로 널리 알려져 있는 파력발전장치인 진동수주형(OWC, Oscillating Water Column) 파력발전시스템을 적용한 curtain식 저반사구조물에 대해 단주기파랑의 작용하에서 공기터빈에 직접 작용하는 압축공기의 흐름속도와 구조물에 작용하는 파압에 관한 특성을 3차원수치실험으로부터 검토한다. 해석에서는 기체와 액체의 혼상동적현상을 동일한 지배방정식으로 해석하는 이상류(二相流) 수치모델에 기초한 3차원수치파동수로를 적용하였다. 이로부터 입사파고의 변화와 curtain wall의 침수심에 따른 압축공기의 속도변화 및 작용파압의 특성을 확인하였고, 더불어 반사율이 최소가 되는 주기에서 압축공기의 최대속도가 발생하는 것을 확인하였다.

공동주택을 위한 PV시스템 적용에 관한 연구 (Study on the Application of PV System for Apartment Buildings)

  • 이소미;노지희;이용호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.276-279
    • /
    • 2007
  • This study aims to present the application of pv system for apartment buildings. Regarding to the domestic housing politics to improve residing environment and effective use of country land, apartment buildings have been constructed since early of 1790's. Now apartment is taking over 50% out of entire housing in Korea. PV System of apartment buildings has been developed periodically and recently gable roof or canopy is popular which pv installation is more favorable. For balcony part with double skin facade sassy window, it has a preferable condition to install on the wall depending on the window direction. In case of superhigh floor apartment buildings where facade is mostly double skin facade of curtain wall system, pv module can replace the traditional curtain wall and will reduce architectural materials and obtain various out look design thereof. So, the purpose of this research is a basic study for clean energy source and present to applicability of pv systems for apartment buildings in preliminary design step.

  • PDF