• Title/Summary/Keyword: current pulse

Search Result 1,871, Processing Time 0.095 seconds

A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map) (PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구)

  • Kim, Ji-Hong;Kim, Jeung-Tae;Kim, Jin-Gi;Koo, Ja-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

Comparison of Improving Dewatering Process at Clay-Sandy Soil based on Pulse-Electrokinetic Technology and Continuous-Electrokinetic Technology (펄스동전기법과 연속처리동전기법을 이용한 점토성-사질토의 탈수화 효율 비교)

  • Shin, Sanghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.4
    • /
    • pp.37-41
    • /
    • 2014
  • Pulse electrokinetic technology is proposed for improving the dewatering-process from clay-sandy soil. Proposed electrokinetic technology is to be the dewatering process due to fluid movement of current flow for the stability of clay-sandy soils. Samples produced in this study were completed to verify the proposed performance for 7 days by gradually increasing the pressure to the final pressure of 30 psi ($2.11kgf/cm^2$) through the compression process. In this study, pulse electrokinetic treatment and conventional continuous electrokinetic treatment are tested and observed, respectively. The condition of continuous electrokinetic treatment is a continuous process during 48 hours. And the condition of pulse electrokinetic treatment system is to interrupt the power three times for 48 hours, every 8 hours. These treatments are that the voltage gradient is 3 V/cm. As a result, the efficiency of pulse electrokinetic is similar to the continuous electrokinetic. The power consumption efficiency of pulse electrokinetic is better than continuous electrokinetic.

Electroplating of Copper Using Pulse-Reverse Electroplating Method for SiP Via Filling (펄스-역펄스 전착법을 이용한 SiP용 via의 구리 충진에 관한 연구)

  • Bae J. S.;Chang G H.;Lee J. H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.2 s.35
    • /
    • pp.129-134
    • /
    • 2005
  • Electroplating copper is the important role in formation of 3D stacking interconnection in SiP (System in Package). The I-V characteristics curves are investigated at different electrolyte conditions. Inhibitor and accelerator are used simultaneously to investigate the effects of additives. Three different sizes of via are tested. All via were prepared with RIE (reactive ion etching) method. Via's diameter are 50, 75, $100{\mu}m$ and the height is $100{\mu}m$. Inside via, Ta was deposited for diffusion barrier and Cu was deposited fer seed layer using magnetron sputtering method. DC, pulse and pulse revere current are used in this study. With DC, via cannot be filled without defects. Pulse plating can improve the filling patterns however it cannot completely filled copper without defects. Via was filled completely without defects using pulse-reverse electroplating method.

  • PDF

A Study on the 「Zhenmairushijie」 by Zhang Yuansu in 『Chandobangronmaekkyulgipseong』 (『찬도방론맥결집성』의 장원소 「진맥입식해」 연구)

  • Jang, Woo-chang
    • Journal of Korean Medical classics
    • /
    • v.32 no.1
    • /
    • pp.1-27
    • /
    • 2019
  • Objectives : By studying the contents of Zhang Yuansu's "Zhenmairushijie", which are introductory remarks of "Chandobangronmaekkyulgipseong", this study attempts to clarify the academic meaning expressed in it and consider his real significance. Methods : First, based on previous studies on Zhang Yuansu and "Wangshuhemaijue", this study divides the contents of "Zhenmairushijie" into 4 chapters and read out the original text. Next, based on Zhang Yuansu's notes and other writings on the original text, this study examines contents in detail. Finally, based on the discussion, this study examines the current significance of academic thoughts expressed in Zhang Yuansu's "Zhenmairushijie". Results & Conclusions : "Zhenmairushijie" emphasizes the combination of nervation and Byeonggi in the process of feeling the pulse for diagnosis, the combination of Byeonggi and Yongyak to declare that the feeling of the pulse for diagnosis is the principle of differential diagnosis. The combination principle of nervation-Byeonggi can be found in comprehensive pulse methods of "Nanjing", and the combination of Byeonggi-Yongyak should follow Ohaeng's Bubuheoshilsajeongbosa principle. Pulse methods of "Wangshuhemaijue" integrated Byeonggi expressed in Uigyeong and Byeonggi in Gyeongbang in the process of the feeling of the pulse for diagnosis to present the principle of diagnosis to perform Byeongjeungronchi. Therefore, "feeling the pulse for diagnosis ipsik" is not only an introductory remark of feeling the pulse for diagnosis, but an comprehensive remark of whole diagnosis as well. It is an introductory remark of the entire medical field due to the nature of oriental medicine which emphasizes diagnosis.

Midinfrared Pulse Compression in a Dispersion-decreasing and Nonlinearity-increasing Tapered As2S3 Photonic Crystal Fiber

  • Shen, Jianping;Zhang, Siwei;Wang, Wei;Li, Shuguang;Zhang, Song;Wang, Yujun
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.250-260
    • /
    • 2021
  • A tapered As2S3 photonic crystal fiber (PCF) with four layers of air holes in a hexagonal array around the core is designed in this paper. Numerical simulation shows that the dispersion D decreases and the nonlinearity coefficient γ increases from the thick to the thin end along the tapered PCF. We simulate the midinfrared pulse compression in the tapered As2S3 PCF using the adaptive split-step Fourier method. Initial Gaussian pulses of 4.4 ps and a central wavelength of 2.5 ㎛ propagating in the tapered PCF are located in the anomalous dispersion region. With an average power of assumed input pulses at 3 mW and a repetition frequency of 81.0 MHz, we theoretically obtain a pulse duration of 56 fs and a compression factor of 78 when the pulse propagates from the thick end to the thin end of the tapered PCF. When confinement loss in the tapered PCF is included in the simulation, the minimum pulse duration reaches 72 fs; correspondingly, the maximum compression factor reaches 61. The results show that in the anomalous-dispersion region, midinfrared pulses can be efficiently compressed in a dispersion-decreasing and nonlinearity-increasing tapered As2S3 PCF. Due to confinement loss in the tapered fiber, the efficiency of pulse compression is suppressed.

Design of a Tripple-Mode DC-DC Buck Converter (3중 모드 DC-DC 벅 변환기 설계)

  • Yu, Seong-Mok;Park, Joon-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 2011
  • This paper describes a tripple-mode high-efficiency DC-DC buck converter. The DC-DC buck converter operate in PWM(Pulse Width Modulation) mode at moderate to heavy loads(100mA~500mA), in PFM(Pulse Frequency Modulation)at light loads(1mA~100mA), and in LDO(Low Drop Out) mode at the sleep mode(<1mA). In PFM mode DPSS(Dynamic Partial Shutdown Strategy) is also employed to increase the efficiency at light loads. The triple-mode converter can thus achieve high efficiencies over wide load current range. The proposed DC-DC converter is designed in a CMOS 0.18um technology. It has a maximum power efficiency of 96.4% and maximum output current of 500mA. The input and output voltages are 3.3V and 2.5V, respectively. The chip size is 1.15mm ${\times}$ 1.10mm including pads.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

A Delta Modulation Method by Means of Pair Transistor Circuit (쌍트랜지스터 회로에 의한 정착변조방식)

  • 오현위
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.2
    • /
    • pp.24-33
    • /
    • 1971
  • A noble method of delta modulation by means of pair transistor circuit having negative resistance charcteristic is presented. An RC parallel circuit is inserted between two eiuitter tarminals of the pair transistor circuit, and their emitters are driven by a square pulsed current source. Basically this is a relaxation oscillator circuit. But when the value of capacitors and resistanc R, and the pulse height of driving source are properly chosen, the RC parallel circuit apparently functions as integrating circuit of driviving pulses. Compared with the integrated voltage of capacitor C, a signal input voltatage supplied in series with RC parallel circuit between two emitters makes on or off either of the pair transistors. as the result, one bit pulse is sent out from the coupling resistance terminal of conducted transistor. The circuit diagram used for this experiment is presented, it i% composed with simple mod ulster circuit, differential amplifier and pulse shaping amplifier, The characteristics of the components of this ciruit are discussed, and especially quantumized noise in this delta modulation system is discussed in order to improve the signal to noise ratio which has a close relation with circut constants, quantumized voltage, pulse height and width of driving current source.

  • PDF

A New DC Ripple-Voltage Suppression Scheme in Three Phase Buck Diode Rectifiers with Unity Power Factor (단위 역률을 갖는 3상 BUCK 다이오드 정류기에서의 새로운 DC 리플-전압 저감 기법)

  • Lee, Dong-Yun;Choy, Ick;Song, Joong-Ho;Choi, Ju-Yeop;Kim, Kwang-Bae;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.154-162
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output ${\gamma}$oltage in three-phase buck d diode rectifiers is presented in this paper. The proposed pulse frequency modulation method is employed to r regulate the output voltage of the buck diode rectifiers and guarantee zero-current switching of the switch over the Vvide load range. The pulse frequency control method used in tIns paper shows generally good p performance such as low THD of the input line current and unity power factor. In addition, the pulse f freιluency method can be effectively used to suppress the low frequency voltage ripple appeared in the dc output voltage. The proposed technique illustrates its validity and effectiveness through the respective s simulations and experiments.

  • PDF