• Title/Summary/Keyword: current lead

Search Result 1,699, Processing Time 0.034 seconds

Rapid Charger for 48V Lead-acid Battery (48V용 납축전지 급속 충전기)

  • Ahn, S.H.;Jang, S.R.;Ryoo, H.J.;Mo, S.C.;Oh, S.W.;Park, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.945_946
    • /
    • 2009
  • This paper describes the development of the rapid battery charger for lead-acid battery. Due to heat which is caused by increased internal resistance during charging, it is difficult to increase charging current for the lead-acid battery. In this paper, the rapid charging algorithm which apply short discharging pulse current during charging procedure is developed and it makes the ion layer, which is generated during charging time, disappeared into electrolyte. The prototype battery charger based on resonant converter is developed for 48V battery charger and test procedure is introduced.

  • PDF

Uptake of Lead by the Lead-tolerant Bacteria (Pb ion내성균(耐性菌)에 의한 Pb의 균체내(菌體內) 축적(蓄積)에 관(關)하여)

  • Hong, Soon Duck;Kim, In Seok
    • Current Research on Agriculture and Life Sciences
    • /
    • v.1
    • /
    • pp.47-53
    • /
    • 1983
  • A strain of Alcaligenes sp. Isolated from the sludge of industrial area was found to uptake 24.1 mg lead/g dried cell during incubation in medium containing 100g/ml of lead. Analyses of cellular subfractions reveal that fractions of cell wall contain 88.6 percent of lead found associated with the cells and the remainder is found associated with the cytoplasmic fraction. Ultrastructural examination of the cells cultured in media containing 500 and 1000g/ml of lead showed no major irregularities between cells of the treated and untreated cultures.

  • PDF

The effect of voltage lead and tape arrangements on self-field losses in a Bi-2223 tape (전압리드 및 테이프 배열이 Bi-2223테이프의 자기자계손실에 미치는 영향)

  • 박권배;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.58-59
    • /
    • 2000
  • The influence of voltage lead and tape arrangements on self-field losses was investigated by using a 1.5m long Bi-2223 tape. Experimental results show that the measured losses are strongly dependent on voltage lead configurations but not contact positions. The losses are independent on frequencies below critical current of the tape. It menas that the self-field losses are purely hysteretic.

  • PDF

Composition and microstructure of Lead-Tin alloy electrodeposits (납-주석합금 도금층의 조성 및 조직특성)

  • 예길촌;지창훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.2
    • /
    • pp.151-160
    • /
    • 2001
  • The composition and the microstructure of the lead-tin alloy electrodeposited in a gluconate bath were invesitigated according to electrolysis conditions. The tin content of the lead-tin alloy electrodeposits increased with increasing current density and EDTA addition, while it decreased with increasing temperature and sodium gluconate concentration. The preferred orientation of the alloy deposits changed from the (220) plane through (200) to (200) + (111) planes with increasing cathode overpotential. The surface morphology of the films was closely related to both the preferred orientation and the alloy composition.

  • PDF

Parametric Study of AC Current Lead for the Termination of HTS Power Cable

  • Kim, D.L;Kim, S.H.;S. Cho;H.S. Yang;Kim, D.H.;H.S. Ryoo;K.C. Seong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.107-110
    • /
    • 2003
  • High Temperature Superconductor (HTS) transmission cable can carry more than 2 to 5 times higher electricity and also obtain substantially lower transmission losses than conventional cables. Liquid nitrogen is to be used to cool the HTS power cable and its cost is much cheaper than the liquid helium used for the cooling of metal superconducting wire. In Korea the HTS power cable development project has been ongoing since July, 2001 with the basic specifications of 22.9kV, 50MVA and told dielectric type as the first 3-year stage. The cryogenic system of the HTS cable is composed of HTS cable cryostat termination and refrigeration system. Termination of HTS cable is a connecting part between copper electrical cable at room temperature and HTS cable at liquid nitrogen temperature. In order to design the termination cryostat, it is required that the conduction heat leak and Joule heating on the current lead be reduced, the cryostat be insulated electrically and good vacuum insulation be maintained during long time operation. Heat loads calculations on the copper current lead have been performed by analytical and numerical method and the feasibility study fer the other candidate materials has also been executed.

Removal of Lead from Lead-loaded Activated Carbon Using Water Electrolysis (물의 전기분해를 이용한 납-흡착 활성탄으로부터 납의 제거)

  • Kim, Bu Ung;Sung, Kyoung Sik;Choi, Yeon Seok
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.929-933
    • /
    • 1999
  • Under the condition of water electrolysis in aqueous hydrochloric acid as the electrolyte, the lead removal from the lead-loaded activated carbon packed on the anode was investigated. The adequate flow condition is a total flow rate of 10 mL/min in the same flow rate ratio to both electrodes. The increase of current decreases pH values at the anode and the decrease of pH leads to the lead removal. This work shows that the water electrolysis is an efficient method for the lead removal from the lead-loaded activated carbon with a reduction in quantity of the chemical used in comparison with the acid rinse.

  • PDF

The Efficient Maintenance System of Lead-acid Battery Based on the Analysis of Charging/Discharging Current (충.방전 전류해석을 통한 납축전지의 효율적인 관리시스템)

  • 박영산;황종구
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.158-169
    • /
    • 2004
  • The efficient maintenance system of lead-acid battery was builted based cm analysis of charging and discharging current. This system was designed for the purpose of protecting the overdischarge of battery. So, We could protect the shortening lifetime of battery. It is checked the charging and discharging current of battery to decide the cut-off point by $\mu$-processor 80c196. Two current sensors were used to sense the current and the $\mu$-processer calculated amount of charging and discharging current of battery. And then display the state of charge.

Low Power Design on Heater and Cathode of Electron Gun for High Resolution CRT (고해상도 CRT용 전자총의 히터 및 캐소드 저전력 설계)

  • Kim Hack-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.618-625
    • /
    • 2005
  • This paper has achieved that an optimal design and experiments of heater and cathode of electron gun that serve to embody high current density in CRT display. For the high brightness, high resolution and larger size in CRT display, high current density of electron gun is indispensible. An Impregnation style cathode is used, and must heighten operating temperature of heater to get high current density for this, it is proportional hereupon and power dissipation increases. In this paper, to get low power cathode with high current density, There are produced and tested sample that differ lead type of heater, coating method, the pitch and number of winding of the first and second coiling in the heat emission area for the low power design of high current density cathode heater in this paper.

A New Three-Phase Lead-Lag Random Pulse Position PWM Scheme for Decreasing Audible Acoustic Noise of Motor Drives (모터 구동 장치의 가청 소음 저감을 위한 새로운 3상 Lead-Lag 랜덤 펄스 위치 PWM 기법)

  • Wi, Seok-O;Jeong, Yeong-Guk;Im, Yeong-Cheol;Na, Seok-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.387-398
    • /
    • 2002
  • In this paper, a new Three-Phase Lead-Lag Random Pulse Position PWM(LL-RPWM) scheme is proposed and implemented for decreasing audible acoustic noise of motor drives. In the proposed RPWM(Random PWM), each of three phase pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of voltage, current as in the case of randomly changed switching frequency. To verify the validity of the proposed LL-RPWM, the simulation and experimental study was tried. Along with the randomization PWM pulses, the space vector modulation is also executed in the C167 micro-controller. The simulation and experimental results show that the voltage and current harmonics are spread to a wide band area and that the audible acoustic noise is reduced by the proposed RPWM method.

Removal of Lead from Sea Water using Electrolysis and Coprecipitation Method (전기분해와 공침법을 이용한 해수중의 납 제거)

  • Jin, Hong-Sung;Lee, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.149-154
    • /
    • 2010
  • The feasibility of lead removal by electrolytic coprecipitation was investigated. Electrolysis bath was divided into anode and cathode chamber with anion exchange resin filled membrane. Sea water was electrolyzed and pH of the electrolyte in cathode chamber was increased. Consequently it induced the formation of $Mg(OH)_2$ and $CaCO_3$. The colloidal type precipitates, hich have high surface area, adsorbed lead ions in sea water and coprecipitated. Sea water electrolyses were conducted at different current density. Concentrations of Mg, Ca and Pb in the solution were measured with titration and ASV method. Morphology and crystallography were analyzed with SEM, EDS and XRD. As pH and current density increased, most of lead ions in the sea water were successfully removed.