• Title/Summary/Keyword: critical current ($I_c$)

Search Result 163, Processing Time 0.031 seconds

Characteristic of Critical Current after Repetitive Bending for High Superconducting Tapes (고온초전도 선재의 Bending횟수에 따른 임계전류의 특성)

  • Kim, Hae-Joon;Joo, J.H.;Kim, S.W.;Kim, H.J.;Bae, J.H.;Cho, J.W.;Seong, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.900-902
    • /
    • 2003
  • Critical current($I_c$) degradation of HTS tapes after bending is one of the holiest issues in HTS development and application studies. Many people are measuring $I_c$ degradations for effect of tending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the $I_c$ degradation after repetitive bending, at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC), Innova Superconductor Technology(InnoST) and Korea Electro-technology Research Institute(KERI). For each specimen $I_c$ degradation was measured various bending radius as function of repetitive bending number.

  • PDF

Novel Interface-engineered Junction Technology for Digital Circuit Applications

  • Yoshida, J.;Katsuno, H.;Inoue, S.;Nagano, T.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • Interface-engineered junctions with $YbBa_2$$Cu_3$$O_{7}$ as the counter electrode were demonstrated. The junctions exhibited excellent Josephson characteristics with a Josephson critical current ($I_{c}$) ranging from 0.1 mA to 8 mA and a magnetic field modulation of the $I_{c}$ exceeding 80% at 4.2 K while maintaining complete c-axis orientation of the counter-electrode layer. The$ 1\sigma$ spreads in $I_{c}$ for junctions with an average $I_{c}$ of 1-2 mA were 5-8% for 16 junctions within a chip, and 9.3% for a 100-junction array. Our dI/dV measurements suggest that a theoretical approach taking into account both a highly transparent barrier and the proximity effect is required to fully understand the Junction characteristics.ristics.

  • PDF

Effect of Heat Treatment on Superconducting Properties on Bi2212/Ag Wire (Bi2212/Ag 선재의 초전도 특성에 대한 열처리의 영향)

  • Kim, S.C.;Ha, D.W.;Song, K.J.;Oh, S.S.;Lee, N.J.;Han, I.Y.;Oh, J.G.;Sohn, H.S.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • We have fabricated double stacked 385 filamentary Bi2212/Ag round wires which have different Ag ratios. The wires have been heat-treated at the maximum temperature($T_{max}$) of $882{\sim}896^{\circ}C$ for 0.5 h. Effect of heat treatment on critical current density and critical temperature on Bi2212/Ag round wires has been studied. Critical current density of the wire heat -treated at $890^{\circ}C$ showed 206,250 $A/cm^2$ at 4.2 K, 0 T and critical temperature of the wire was 83 K. Microstructure of the wires also has been studied via optical microscopy and SEM.

  • PDF

Study on the Critical Current of Field Coil for High Temperature Superconducting Motor (고온초전도 전동기용 계자코일의 임계전류 연구)

  • Jo, Young-Sik;Sohn, Myung-Whan;Baik, Seung-Kyu;Kwon, Woon-Sik;Lee, Eon-Yong;Kwon, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.873-875
    • /
    • 2003
  • It is well known that $I_c$ (critical current) in HTS tape is more sensitive to $B{\perp}$ (magnetic field amplitude applied perpendicular to the tape surface) than to B// (magnetic field amplitude applied parallel to the tape surface). Thus, the magnitude of $B{\perp}$ at HTS tape is important to the design of HTS motor, because it determines the operating current. In addition, the $I_c$ of HTS field coil is determined by not only the $B{\perp}$ but also stress and strain condition at given operating temperature. Therefore, at the stage of field coil design, stress and strain conditions should be considered because when the HTS tape is handled, it is necessary to know the limiting values of loading, bending and twisting to avoid any damages. The $I_c$ of field coil is calculated by 3D analysis and measured through experiments considering the $B{\perp}$ and the margin of contacts loss.

  • PDF

Variation of the Transport Property in Lap-Jointed YBCO Coated Conductor Tapes with Tension and Bending Deformation

  • Dizon, John Ryan C.;Bonifacio, Rolly;Park, Sung-Taek;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.4
    • /
    • pp.11-15
    • /
    • 2007
  • In practical applications of HTS tapes for electric devices such as coils and power cables, the jointing of HTS tapes is inevitable even though long length tapes have recently been achieved. The critical current, $I_c$, degradation behaviors with tensile and bending deformations were investigated in commercially available YBCO coated conductor tapes. When the V-I relationship was measured at the jointed section of the lap-jointed YBCO CC tapes, the resistance at the joint decreased with increasing joint length. The critical load for 95% $I_c$ retention were determined for the IBAD and RABiTS YBCO tapes and they were 175 and 355N, respectively. Fracture occurred at the unjointed part which represents strong copper lamination and solder jointing. The electro-mechanical properties of lap-jointed CC tapes depended on the properties of single tapes. The V-I behavior under bending strain was similar with the tensile case.

Effects of Heat-treatment Temperature on the Critical Current of BSCCO 2212 Tube Prepared by CMP Method (CMP 방법으로 제조한 BSCCO 2212 튜브의 임계전류특성에 미치는 열처리 온도의 영향)

  • Choi, Jung-Suk;Oh, Sung-Young;Jun, Byung-Hyuk;Kim, Hyoung-Seop;Kim, He-Lim;Hyun, Ok-Bae;Kim, Chan-Joong
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.98-103
    • /
    • 2006
  • [$Bi_2Sr_2Ca_1Cu_2O_x$](BSCCO 2212) tubes were fabricated by centrifugal melting process(CMP). BSCCO 2212 powder was melted in a Pt crucible and solidified in a rotating steel mold. The BSCCO 2212 tube samples separated from steel mold were heat-treated at $800^{\circ}C\;and\;810^{\circ}C$ in oxygen flow. The critical current($I_c$) of the samples was measured by transport measurement at 77K, and the microstructure was investigated by scanning electron microscope. The $J_c$ at 77K of the tubes heated treated at $800^{\circ}C\;and\;810^{\circ}C$ were 197 and 240 $A/cm^2$, respectively. It was observed that the plate like grains in BSCCO 2212 tube was more developed in the sample heat treated at $810^{\circ}C\;and\;800^{\circ}C$ heated tube. It is found that the critical current($I_c$) of the BSCCO 2212 sample was dependent on the heating schedule regarding the growth of the BSCCO 2212 grains.

  • PDF

Magnetic field dependence of critical current and index n in a Bi-2223/Ag superconductor tape (Bi-2223/Ag 초전도 선재에서 임계전류와 인덱스의 자계의존성)

  • Kim Jung Ho;Kim Kyu Tae;Lim Jun Hyung;Jang Seok Hern;Rho Yun Bong;Joo Jinho;Choi Seyong;Nah Wansoo;Hong Gye-Won
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.79-83
    • /
    • 2004
  • We fabricated Bi-2223/Ag superconductor tape with 55 filaments and estimated the magnetic field dependence of critical current (I$_{c}$) and index n (n) up to 30 T at 4.2 K. The I$_{c}$ and n were characterized as a function of external magnetic field parallel to the tape surface on increasing and decreasing field, using a 35 T hybrid magnet. The $I_{c}$ was estimated to be 325 A, and n was 32, 22, and 26 in the electric field range of $0.1 ∼1\mu$V/cm, 1∼10 $\mu$V/cm, and 0.1∼10 $\mu$V/cm, respectively, under self-field at 4.2 K. It was observed that $I_{c}$ was dependent on magnitude of magnetic field and it decreased exponentially as the field increased; in a parallel and increasing field, It was 128 A at 30 T which is approximately 40% of critical current in self-field. In addition, the $I_{c}$ was higher on decreasing field than that on increasing one. On the other hand, n did not significantly depend on field strength up to 30 T, nor varied on whether increasing or decreasing field; n value in 0.1∼1 $\mu$V/cm was 23.0$\pm$5.2 and 27.8$\pm$8.0 on increasing and decreasing field, respectively. The n value on decreasing magnetic field was slightly higher than that on increasing field. This hysteretic behavior of n was similar to that of$ I_{c}$, which is related to the trapped flux at the grain boundary.ary.

  • PDF

Effect of transverse compressive stress on $I_{c}$ degradation characteristics in Bi-2223 superconducting tapes (Bi-2223 초전도테이프의 임계전류 열화특성에 미치는 횡방향 압축응력의 영향)

  • 신형섭;김병수;오상수;하동우;하홍수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.101-104
    • /
    • 2003
  • Influences of transverse compressive stress on the critical current ( $I_{c}$) in AgMg and AgMn alloy sheathed Bi-2223 tapes were investigated at 77 K and 0 T. The $I_{c}$ degradation behavior depending on sample specifications was discussed in viewpoints of n-value and damage morphology. As a result, Bi-2223 tapes showed a significant drop in $I_{c}$ for stresses greater than 50MPa. The AgMg sheathed Bi-2223 tapes representing higher $I_{c}$ showed a lower $\sigma$$_{irr}$ and a significant $I_{c}$ degradation with increase in compressive stress. There existed a voltage tap separation dependency of the $I_{c}$ degradation behavior caused by the transverse compressive stress.sive stress.s.

  • PDF

Effect of Tensile Strain on $I_c$ Degradation Characteristics In Bent Externally Reinforced Bi-2223 Superconducting Tapes (굽힘상태의 외부보강한 Bi-2223 초전도테이프에서 임계전류 열화특성에 미치는 인장변형률의 영향)

  • 신형섭;김기현;오상수;하동우
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.6-11
    • /
    • 2004
  • The influences of mixed strain mode of bending-tension on the critical current. Ic in externally reinforced Bi-2223 tapes and their interaction were investigated in this study. A test fixture which providing a mixed deformation mode of bending-tension to HTS tapes has been newly devised. When the total strain induced in the tape in the mixed strain mode was expressed by the superposition of the bending and tensile strains the irreversible strain for the critical current degradation of Bi-2223 tapes increased, as compared with the simple bending mode case. The $I_c$ degradation at the region exceeding the irreversible strain showed a medium between the simple bending case and the simple tension case. As the initial bending strain imparted increased , namely as the diameter of mandrel adopted decreased. the apparent irreversible strain in Bi-2223 tapes increased . but the increment became smaller As a result. it can be found that the tension to be applied to bent Bi-2223 tapes during cabling should be smaller. as the mandrel diameter becomes smaller.

$I_c$ Degradation Behavior in YBCO Coated Conductors under Torsional Strain (YBCO 박막도체의 비틀림 변형률에 따른 임계전류 열화거동)

  • Shin, Hyung-Seop;Dizon, John Ryan C;Kim, Tae-Young;Ko, Rock-Kil;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.93-94
    • /
    • 2006
  • The $I_c$ degradation behavior of YBCO CC tapes due to torsional deformation has been investigated. Particularly, the influence of torsion angle on the $I_c$ in HTS tapes was examined at 77K (self-field). At low torsional angles or shear strains, the $I_c$ degradation was small and gradual. Also, a good consistency of the $I_c$ degradation behaviors was found along the longitudinal direction under torsion when multiple voltage terminals were adopted for investigating the homogeneity of the $I_c$ degradation.

  • PDF