• 제목/요약/키워드: criteria of deterioration

검색결과 154건 처리시간 0.02초

Determination of Ratio of Wood Deterioration Using NDT Technique

  • Lee, Jun-Jae;Bae, Mun-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권3호
    • /
    • pp.33-41
    • /
    • 2004
  • In ancient wooden structures, the mechanical properties of the structural members have been reduced by time-dependent degradations such as fatigue or creep. Also, the external and internal deterioration was caused by environmental condition, fungi, bacteria, or insect, and then reduced the quality of structural members. However, the previous methods for evaluating the deterioration have been mainly depended on the visual inspection. In this study, therefore, ultrasonic stress wave test, accelerometer stress wave test were used to evaluate the deterioration of structural wood members in ancient wooden structures. Based on the results, the quantitative criteria of stress wave transmitted velocity were proposed to evaluate the deterioration of structural member. The proposed criteria were related to the degree of deterioration. In accelerometer stress wave, the criteria of deterioration of wave reciprocal velocity was below 1800 ㎲/m at incipient deterioration (below 12% ratio of deterioration), between 1800 and 2200 ㎲/m at moderate deterioration (12~17%) and above 2200 ㎲/m at severe deterioration (above 17%). The ultrasonic stress wave, the criteria of deterioration were 800 and 950 ㎲/m at below 8% and above 15% of the degree of deterioration respectively.

학교건물(學校建物) 건축설비(建築設備)시스템의 노후도(老朽度) 평가(評價) 기준(基準)마련을 위한 기초연구(基礎硏究) (Evaluation of Deterioration Grade for Remodeling Architectural Facilities in Old Schools)

  • 조민관;조창근;박종수
    • 교육시설
    • /
    • 제13권4호
    • /
    • pp.15-23
    • /
    • 2006
  • The purpose of this study is to establish the objective deterioration grades and evaluation criteria of building equipment system of educational facilities available for reasonable maintenance and remodeling of them. For the purpose of it, the actual conditions of building equipment systems of the 148 buildings of 84 middle and high schools in Seoul 20 years after construction are investigated and surveyed through one-on-one interviews and questionnaires. And, deterioration grades of them are estimated by the evaluation criteria which is proposed in this study. As a result of this study, the 10 deterioration grades and the 4 evaluation criteria of the 6 performances of building equipment system, which are heating and cooling, water supply and drainage, hot water supply and electrical power performance, are suggested. And, as a result of the survey, it showed that 24% of the investigated school buildings were estimated C grade which needs partial remodelling, and 51% of the school buildings were estimated D grade which needs extensive remodelling. And, 25% of the school buildings were estimated E grade which needs overall remodelling or alteration of building equipment system.

산업시설 배관의 섹션화에 의한 노후도 평가 (Deterioration Evaluation for Industrial Pipeline by Sectionalizing)

  • 민혁기;김상범;김병우;김형기;박률
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.123-130
    • /
    • 2016
  • This study introduced deterioration evaluation item and criteria that could be applied to industrial facilities with the most widely used carbon steel pipe installed for ordinary piping (KSD 3507). Experimental industrial pipes were evaluated with pipe sectionalizing method combined with the established evaluation item and criteria to measure and manage semi-continuously for overall piping system. After applying outcomes from this study to a plant of incineration facility, a 42% saving in repairing and remodeling cost was achieved.

노후공동주택의 거주성능 평가에 관한 사례 연구 (A Case Study on the Evaluation of Residential Performance for Deteriorated Multi-family Housing)

  • 현택수;이병태
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.77-85
    • /
    • 2006
  • This study aims to propose the comprehensive evaluation of performance multi-family housing. Most of the existing studies for the reproduction have evaluated by the safety of structure. Therefore those pass over the functional factors which is important for the evaluation of residential qualities. This study represents that the reproduction renovation should not be secured the safety of structure but established the quality of lift. And questionnaire asking expert's opinion also supplemented. As a result, the item for examination and the weight for evaluation are suggested in functional deterioration. The results of this study are summarized as follows: 1. Existent redevelopment criteria are not appropriate to decide the environmental comfort, the vital function of housing and the residential management finance. 2. The future criteria have to evaluate the existing environmental comfort, be reconstructed to put first general deterioration. 3. Evaluation elements was extracted throughout the document research, evaluation elements analysis system was separated in residential area, suburb of dwellings, community, and housing complexity environmental assesment, 4. Each category of influence ratio was extracted to assess total deterioration throughout the expert question survey. 5. Each category analysed (1) $0{\sim}30%$: function is good (unnecessary to improve) (2) $31{\sim}40%$: average (necessary of partial improvement) (3) $41{\sim}59%$: bad (necessary of total improvement) (4) $60{\sim}100%$: the worst (unable to improve throughout the repair)

Rock burst criteria of deep residual coal pillars in an underground coal mine: a case study

  • Qiu, Pengqi;Wang, Jun;Ning, Jianguo;Liu, Xuesheng;Hu, Shanchao;Gu, Qingheng
    • Geomechanics and Engineering
    • /
    • 제19권6호
    • /
    • pp.499-511
    • /
    • 2019
  • The reliability of reinforced concrete structures is frequently compromised by the deterioration caused by reinforcement corrosion. Evaluating the effect caused by reinforcement corrosion on structural behaviour of corrosion damaged concrete structures is essential for effective and reliable infrastructure management. In lifecycle management of corrosion affected reinforced concrete structures, it is difficult to correctly assess the lifecycle performance due to the uncertainties associated with structural resistance deterioration. This paper presents a stochastic deterioration modelling approach to evaluate the performance deterioration of corroded concrete structures during their service life. The flexural strength deterioration is analytically predicted on the basis of bond strength evolution caused by reinforcement corrosion, which is examined by the experimental and field data available. An assessment criterion is defined to evaluate the flexural strength deterioration for the time-dependent reliability analysis. The results from the worked examples show that the proposed approach is capable of evaluating the structural reliability of corrosion damaged concrete structures.

아파트 노후도 평가지표 개발을 위한 기초연구 (A Preliminary Study on Housing Performance Indicators Evaluating the level of Deterioration of Apartments)

  • 조성희;이태경
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.225-230
    • /
    • 2008
  • High-rise and high-density apartment complexes has been built and supplied on a large scale in the metropolis and metropolitan areas since 1980s in order to solve housing shortage in cities. Recently they are raising deterioration problems for aging more than 20 years. moreover, those problems show very special characters such as simultaneity and a large scale. The purpose of this study is to propose a direction for the development of the evaluating indicators to measure the level of deterioration of apartments. The level of deterioration of apartments can be evaluated by housing performance. In order to evaluate the deterioration comprehensively, the housing performance indicators should be developed on the social, economical, and physical dimension. This study analyzed the concept of the apartment deterioration and compared housing performance indicators through literature review. First of all, when considering various factors in the evaluation of the deteriorated apartments, such as evaluating ranges, attributes and dimensions, housing performance indicators should be structured with the hierarchical framework. Second, housing performance indicators evaluating the level of deterioration of apartments should include social, psychological, and cultural aspects of home environments in order to understand adequately the attitude of the middle class toward services that apartments provide. Third, in previous researches, most criteria have been developed and weighted based on only expert opinions regarding performance indicators. So, It is necessary to include residents' opinions in developing performance indicators since they can provide more practical and feasible aspects the experts could not experience or understand.

  • PDF

교량용 탄성받침의 설계압축응력에 대한 고찰 (The Design Criteria of Elastomeric Bearing for Highway Bridges)

  • 전규식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.136-143
    • /
    • 1998
  • Elastomeric bearing is used as one of the most useful way for isolation structures, because the horizontal stiffness is much lower than the vertical stiffness. The quality of Elastomeric bearing depends on the vulcanization procedure to manufacture, which produces the elasticity of the rubber from the compound of rubber and sulphur. The durability of Elastomeric bearing is affected by the deterioration due to ozone and ultra-violet attack. but the durability during the design life of bridges can be assured by the sufficient size of the bearing in spite of the deterioration in surface. In the design criteria of Elastomeric bearing, the stability of the bearings is evaluated by shear strain due to compression, lateral displacement, and rotation. The question how soft rubber can sustain heavy structure is now able to be solved by Ultimate capacity test of Laminated elastomeric Bearings, which results 1,200kg/$\textrm{cm}^2$ of the max. compressive stress and this shows what a sufficient safety factor Elastomeric bearing has!

  • PDF

수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구 (A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment)

  • 윤상천;신동철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.197-205
    • /
    • 2020
  • 주택법(2014년)에 근거하여 철근콘크리트 공동주택의 리모델링 시 수직 및 세대수 증축이 가능하게 되었다. 수직증축 리모델링 가능 여부는 안전진단 기준 및 매뉴얼을 바탕으로 기울기 및 침하, 내하력, 내구성 평가 부문에 대한 평가를 통하여 판정하도록 되어 있다. 그러나 증축형 리모델링 기준 및 매뉴얼 제정 당시, 국내에서는 수직증축 리모델링 안전진단 사례가 전무하여 평가기준 등에 대한 공학적 근거 제시에 한계가 있었으며, 특히 내구성 평가 기준에 대한 합리화 및 관련 기준과의 부합을 위한 개선이 필요한 것으로 생각된다. 따라서 본 연구에서는 국내외 내구성 관련 기준을 근거로 콘크리트 탄산화, 염분함유량, 균열, 철근부식, 표면노후도의 허용치와 평가기준에 대한 검토·분석을 통하여 수직증축형 리모델링 안전진단 내구성 평가방법의 합리화 방안을 제시하였다.

유전자 알고리즘을 이용한 항공기용 가스터빈 엔진의 단일 결함 진단에 대한 연구 (A Study on Diagnostics of Single Performance Deterioration of Aircraft Gas-Turbine Engine Using Genetic Algorithms)

  • 김승민;용민철;노태성;최동환
    • 한국항공우주학회지
    • /
    • 제35권3호
    • /
    • pp.238-247
    • /
    • 2007
  • 유전자 알고리즘은 자연선택과 유전법칙을 적용하여 최적해를 탐색하는 방법으로, 본 연구에서 항공기용 가스터빈 엔진의 결함 진단을 위한 학습 알고리즘으로 사용되었다. 성능 저하를 고려한 구성요소는 압축기, 가스발생기 터빈, 동력 터빈이며, 설계점에서 엔진의 단일 구성요소에 대하여 각각 성능 저하 예측을 수행한 후, 이를 바탕으로 결함 진단을 수행하였다. 학습데이터 수의 증가가 유전자 알고리즘을 이용한 성능 저하 예측 및 결함 진단에 미치는 영향을 분석하였으며, 결과적으로 결함치에 대한 RMS 오차율이 모두 3% 이내로 예측됨을 확인하였다.

고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정 (Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • 전력 수요는 매년 증가추세에 있으며, 이에 따라 발전소에서 동작하는 모든 장비들과 대용량의 장거리 전력수송을 위한 장비들은 신뢰할 수 있는 수준에서 완전한 상태로 동작하여야 한다. 발전소에서 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 우리는 이 논문에서 케이블의 열화 판정의 기준을 설정하고, 기준에 따른 열화정도를 판정하고, 케이블의 대체여부를 결정함으로써 발전소에서 설치된 활선 케이블의 동작 상태를 감시한 결과와 케이블을 구성하고 있는 절연체와 방식층이 절연저항 특성에 미치는 영향 및 케이블의 동작에 미치는 영향을 연구한 결과를 제시한다.