• Title/Summary/Keyword: corrosion area

Search Result 571, Processing Time 0.032 seconds

A study on change in electric contact resistance of the tin-plated copper connector of automotive sensor due micro-vibration (차량용 주석 도금된 구리 커넥터에서 미세진동에 의한 전기접촉 저항변화에 관한 연구)

  • Yu, Hwan-Sin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.653-658
    • /
    • 2008
  • The automotive environment is particularly demanding on connector performance, and is characterized by large temperature changes, high humidity and corrosive atmospheres. Fretting is a contact damage process that occurs between two contact surfaces. Fretting corrosion refers to corrosion damage at the asperities of contact surfaces. This damage is induced under load and in the presence of repeated relative surface motion, as induced for example by vibration. This paper critically reviews the works published previously on fretting corrosion of electrical connectors. Various experimental approaches such as testing machines, material selection, testing environments, acceleration testing techniques and preventing methods are addressed. Future research prospects arc suggested.

  • PDF

Corrosion and Strength Degradation Characteristics of 1.25Cr-0.5Mo Steel under SO2 Gas Environment (SO2 가스 환경 하에서 1.25Cr-0.5Mo 강의 부식 및 강도 저하 특성)

  • Jung, Kwang-Hu;Kim, Seong-Jong
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.3
    • /
    • pp.149-156
    • /
    • 2018
  • The corrosion and strength degradation characteristics of 1.25Cr-0.5Mo steels were studied under $650^{\circ}C$ in $76%N_2+6%O_2+16%CO_2+2%SO_2$ gas condition up to 500 hrs. Corroded specimens were characterized by weight gain, scanning electron microscope(SEM), energy dispersive X-ray spectroscopy(EDS), and X-ray diffraction(XRD). The tensile test was conducted to evaluate the mechanical strength and fracture mode with corrosion at high temperature. As the results of the experiments, thick Fe-rich oxide layers over $200{\mu}m$ were formed on the surface within 500 hrs. The thick oxide layers are formed with reduction of the cross-sectional area of the specimens. Thus, the strength tended to decrease with reduction of the cross-sectional area.

The Study on the Effects of Air Pollution on the Material Damages in Northeast Asia

  • Kim, Sun-Tae;Yasuaki Maeda
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E2
    • /
    • pp.51-61
    • /
    • 2003
  • The material exposure tests have been carried out since 1993 to evaluate the relationship between air pollution and material corrosion with the cooperation of the researchers in Japan, China, and Korea. The test pieces such as bronze, copper, marble, and carbon steel have been exposed under both unsheltered and rain-sheltered outdoor condition separately at 18 sampling sites in East Asia. At the same time, the concentration of SO$_2$ and NO$_2$ has been measured simultaneously with passive sampler. The meteorological data were collected from the AWS (Auto-mated weather station) In each country and chemical compositions of wet deposition were also analyzed by the bulk sampling of rainfall every month. As the results, it was found that the corrosion rates of test pieces in the ambient air were appeared to be in the order of carbon steel > marble > bronze copper. The corrosion rates of test pieces in the unsheltered outdoor condition were 2.34 to 5.88 times larger than those in rain-sheltered condition. It was also found that the corrosion rate in the heavy polluted area in China was the highest, and the corrosion rates of the metal pieces were generally proportional to SO$_2$ concentration. Between two sites in Korea, the test pieces at Daegu site showed higher corrosion rates that would be due to the higher SO$_2$ concentration.

Earthquake response of reinforced concrete frame structures subjected to rebar corrosion

  • Yuksel, Isa;Coskan, Seda
    • Earthquakes and Structures
    • /
    • v.5 no.3
    • /
    • pp.321-341
    • /
    • 2013
  • This paper investigates earthquake response of reinforced concrete regular frames subjected to rebar corrosion. A typical four-story reinforced concrete frame is designed according to Turkish Earthquake Code in order to examine earthquake response. Then different levels of rebar corrosion scenarios are applied to this frame structure. The deteriorated conditions as a result of these scenarios are included loss in cross sectional area of rebar, loss of mechanical properties of rebar, loss in bond strength and variations in damage limits of concrete sections. The frame is evaluated using a nonlinear static analysis in its sound as well as deteriorated conditions. The rebar corrosion effect on the structural response is investigated by comparing the response of the frame in each scenario with respect to the sound condition of the frame. The results shows that the progressive deterioration of the frame over time cause serious reductions on the base shear and top displacement capacity and also structural ductility of the corroded frames. The propagation time, intensity, and extensity of rebar corrosion on the frame are important parameters governing the effect of rebar corrosion on earthquake response of the frame.

Influences of Anodizing and Thermal Oxidation on the Galvanic Corrosion between Aluminium and Titanium and GECM (GECM과 Al 및 Ti 간의 갈바닉 부식에 미치는 양극산화 및 열산화의 영향)

  • Kim, Young-Sik;Lim, Hyun-Kwon;Sohn, Young-Il;Yoo, Young-Ran;Chang, Hyun-Young
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.6
    • /
    • pp.514-522
    • /
    • 2010
  • Graphite epoxy composite material (GECM) shows high specific strength and its application in the aerospace industry is gradually increasing. However, its application would induce galvanic corrosion between GECM and metallic materials. This work focused on the effects of anodizing and thermal oxidation on galvanic corrosion in a 3.5% NaCl solution between GECM and aluminium and titanium. In the case of anodized aluminium, galvanic corrosion resistance to the GECM was greatly improved by the anodizing treatment regardless of area ratio. In the case of anodized titanium, the anodizing by a formation voltage of 50V increased corrosion resistance of titanium in galvanic tests. Thermal oxidation of titanium also improved corrosion resistance of Ti to GECM.

Corrosion Protection Effectiveness and Adsorption Performance of Whey Inhibitor with Cocoa for Mild Steel in Hydrochloric Acid Environment

  • Hawraa W. Abd Muslim;A. M. Mustafa;F. F. Sayyid
    • Corrosion Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.343-351
    • /
    • 2024
  • A weight loss technique was used to stabilize whey protein (97%) with a small percentage of cocoa (3%) and bond it to a mild steel surface in hydrochloric acid at temperatures ranging from 303 K to 333 K. Results of analyzing whey inhibitor's effectiveness showed the highest percentage (90%) at a temperature ranging from 30 ℃ to 60 ℃ and an amount of 15 grams, leading to outstanding corrosion resistance properties. The efficiency of the inhibitor increased with increasing concentration but decreased with increasing temperature. To evaluate corrosion areas, samples were subjected to cross-section analysis before and after adding the inhibitor. The contact angle test conducted on steel alloys indicated that the angle decreases with increasing inhibitor concentration. Adhesion of the samples was also examined after adding the inhibitor. Results showed that the best area removal was 11.692%. When examining the inhibitor using FTIR spectroscopy, the whey protein with cocoa showed a great efficiency. Thus, whey inhibitor can be used as a corrosion inhibitor for mild steel alloys immersed in acidic conditions.

An Analysis on Storing Container Corrosion of Powder Extinguisher according to Durable Years of Each Type-3 Powder Extinguisher (제3종 분말소화기 대상별 내용연수에 따른 저장용기의 부식도 분석)

  • Son, Ju-Dal;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.661-666
    • /
    • 2022
  • This study presented the criteria for analyzing the corrosion of the powder extinguisher storage container according to the useful life, and conducted an experiment on the market area, the factory area, and the apartment building area to ensure proper performance at all times and drew the following conclusions.First, the experimental value for the degree of corrosion of external contact storage containers was found to be unsuitable in the factory area in 2014. In 2012, the experimental value for the degree of corrosion of external contact storage containers in apartment complexes was found to be inappropriate. Second, the experimental value for the dropout of the external paint in the storage container was found to be inappropriate in the factory area in 2014. In 2012, the experimental value of the degree of coating of the external paint storage container in the apartment building area was found to be inappropriate. It was analyzed that the useful life of the fire extinguisher is 10 years, and if it passes the sample test only once, it will be used for up to 13 years, but in fact, the difference varies greatly depending on the surrounding environment of the fire extinguisher place. Since the degree of corrosion of the storage container of the fire extinguisher from 8 years of the fire extinguisher's useful life is clearly decreased, it is judged that 5 years of the fire extinguisher is appropriate.

Effects of Expanding Methods on Residual Stress of Expansion Transition Area in Steam Generator Tube of Nuclear Power Plants (원전 증기발생기 전열관 확관법이 확관부위 잔류응력에 미치는 영향)

  • Kim, Young Kyu;Song, Myung Ho
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.362-372
    • /
    • 2012
  • The steam generator tubes of nuclear power plants are pressure boundaries, and if tubes are leaked, the coolant with the radioactive materials was flowed out from the primary system to the secondary system and polluted the plant and the air. Recently most crack defects of tubes are stress corrosion cracks and these defects are located in expansion transition area, sludge pile-up region, and U-bend area. The most effective one of crack initiation factors in expansion transition area and U-bend area is the residual stress. According to the experiences of Korea standard nuclear plants(Optimized Power Reactor-1000), they had the stress corrosion cracks at the tube expansion transition area in early operating stage and especially lots of circumferential cracks were occurred. Therefore in this study, the distributions and conditions of residual stresses by tube expansion methods were compared and the dominant reason of a specific direction was examined.

Investigation of shinning Spot Defect on Hot-Dip Galvanized Steel Sheets

  • Liu, Yonggang;Cui, Lei
    • Corrosion Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.125-129
    • /
    • 2014
  • Shinning spot defects on galvanized steel sheets were studied by optical microscope, scanning electron microscope(SEM), Energy Dispersive Spectrometer (EDS) and Laser-Induced Breakdown Spectroscopy Original Position Statistic Distribution Analysis (LIBSOPA) in this study. The research shows that the coating thickness of shinning spot defects which caused by the substrate defect is much lower than normal area, and when skin passed, the shinning spot defect area can not touch with skin pass roll which result in the surface of shinning spot is flat while normal area is rough. The different coating morphologies have different effects on the reflection of light, which cause the shinning spot defects more brighter than normal area.

Effect of Induction Heat Bending Process on the Corrosion Properties of 316 Stainless Steel Pipes for Nuclear Power Plant (원자력발전소용 316 스테인리스강 배관의 부식특성에 미치는 유도가열벤딩공정의 영향)

  • Shin, Mincheol;Kim, Young Sik;Kim, Kyungsu;Chang, Hyunyoung;Park, Heungbae;Sung, Giho
    • Corrosion Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.87-94
    • /
    • 2014
  • Recently, the application of bending products has been increased since the industries such as automobile, aerospace, ships, and plants greatly need the usage of pipes. For facility fabrication, bending process is one of key technologies for pipings. Induction heat bending process is composed of bending deformation by repeated local heat and cooling. Because of local heating and compressive strain, detrimental phases may be precipitated and microstructural change can be induced. This work focused on the effect of induction heat bending process on the properties of ASME SA312 TP316 stainless steel. Evaluation was done on the base metal and the bended areas before and after heat treatment. Microstructure analysis, intergranular corrosion test including Huey test, double loop electropotentiokinetic reactivation test, oxalic acid etch test, and anodic polarization test were performed. On the base of microstructural analysis, grain boundaries in bended extrados area were zagged by bending process, but there were no precipitates in grain and grain boundary and the intergranular corrosion rate was similar to that of base metal. However, pitting potentials of bended area were lower than that of the base metal and zagged boundaries was one of the pitting initiation sites. By re-annealing treatment, grain boundary was recovered and pitting potential was similar to that of the base metal.