• Title/Summary/Keyword: conventional method

Search Result 17,691, Processing Time 0.04 seconds

이동영역을 틀 영상으로 한 실시간 자동목표 추적

  • 천인서;김남철;장익훈
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.52-55
    • /
    • 1987
  • In tihis paper an improved matching method using subtemplate of moving region and 3-step search algorithm is proposed It reduces heavy computational load of the conventional method. The proposed method is applied to an automatic target tracker using high speed 16 bit microprocessor in order to track one moving target in real time. Expericmental results show that the proposed method has better performance over the conventional methodin spite of greately reducing the computational load, even in came complex background.

  • PDF

Measurement of Varying Stimulus Evoked Otoacoustic Emission Latency Using cross Correlation (상호상관법을 이용한 가변 자극 유발이음향 방사파 잠시의 측정)

  • 최진영;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.19-22
    • /
    • 1991
  • Cross correlation method was newly applied for the calculation of latency of evoked otoacoustic emission. The latency was calculated froth the main peak of cross correlation function, which is one of Possible definition of latency. The output was also compared with those of conventional autocorrelation method. The results show that cross correlation method has better Performance than that of conventional method.

  • PDF

DEVELOPMENT OF CALCULATION METHOD OF SENSITIVITIES FOR LIGHT WATER REACTORS

  • Takeda, Toshikazu;Foad, Basma
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.753-758
    • /
    • 2013
  • A new method of calculating sensitivity coefficients of core characteristics relative to infinite-dilution cross sections has been developed. Conventional sensitivity coefficients are evaluated for the changes of effective cross sections which are dependent on individual models of core and cell. Therefore a correction has been derived to the conventional sensitivity coefficients based on the perturbation theory. The accuracy of the present method has been verified by comparing numerical results of sensitivity coefficients with a reference Monte-Carlo method.

Dispersion Analysis of the Waveguide Structures by Using the Compact 2D ADI-FDTD (Compact 2D ADI-FDTD를 이용한 도파관 구조의 분산특성 연구)

  • 어수지;천정남;박현식;김형동
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.10
    • /
    • pp.38-45
    • /
    • 2002
  • This paper presents the new Compact 2D ADI-FDTD(Alternating-Direction Implicit Finite-Difference Time-Domain) method, where the time step is no longer restricted by the numerical stability condition. This method is an accelerating algorithm for the conventional Compact 2D FDTD method. To validate this algorithm, we have analyzed the dispersion characteristics of the hollow rectangular waveguide and the shielded microstrip line. The results of the proposed method are very well agreed with those of both the conventional analytic method and the Compact 2D FDTD method. The CPU time for analysis of this method is very much reduced compared with the conventional Compact 2D FDTD method. The proposed method is valuable as a fast algorithm in the research of dispersion characteristics of the waveguide structures.

A Study on the Contrast Ratio Improvement of Surface Discharge AC PDP (면방전 AC PDP에서 콘트라스트 개선에 관한 연구)

  • An, Yang-Ki;Yoon, Dong-Han
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.11
    • /
    • pp.536-540
    • /
    • 2002
  • This paper proposes a method to drive an AC plasma display panel(PDP) with a significantly improved contrast ratio. In the proposed method, during the first sub-field of one frame, all PDP cells are reset by the ramp waveform, and during the other sub-field, only the cells turned on in the previous sub-field are reset. No light is emitted during the reset period of every sub-field except the first sub-field. For a 10-bit picture, the luminance of the dark level for the proposed method is 10 times lower than that for the conventional method, in which the ramp waveform for the reset is used in every sub-field. Accordingly, the contrast ratio for the proposed method is 10 times higher than that for the conventional method. For the 10-bit picture, the measured contrast ratio was about 3080:1 for the proposed method and about 285:1 with the conventional method, a result the contrast ratio has been increased in 10.8 times. This result shows that the proposed method can realize an image with high contrast ratio.

Comparison of Microwave with Conventional Wet-Digestion Methods for the Element Analysis of Plant and Compost (식물체 및 퇴비 성분 분석을 위한 마이크로웨이브 분해법과 기존 습식 분해법의 비교)

  • Nam, Jae-Jak;Cho, Nam-Jun;Jeong, Yee-Guen;Lee, Sang-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.3
    • /
    • pp.253-258
    • /
    • 1998
  • To verify the suitability of microwave digestion method for analyzing macro nutrients and metals. K, Ca, Mg, Cu, Zn, and Mn contents in plant and composts were investigated comparing with conventional wet digestion method. Because it takes short time to digest metal samples by using microwave method compared with conventional wet digestion method. Digestion time for metal samples was four to six hours long for wet digestion, while one hour long for microwave digestion. Determinant coefficients of Cu, Mn, Zn, Ca, K, and Mg contents between two analyzing methods were 0.99, 0.99, 0.94. 0.97, 0.98, and 0.91, respectively. In the case of Ca and K, microwave digestion method analyzed their contents relatively low compared with wet digestion method. Meanwhile, microwave digestion method analyzed the contents for Cu, Ma, and Zn relatively high compared with wet digestion method. This study results in that microwave digestion method could be an alternative to replacing conventional wet digestion method.

  • PDF

Diagnostic Value of Urine Cytology in 236 cases; a Comparison of Liquid-Based Preparation and Conventional Cytospin Method (요 세포 검사의 진단적 가치; 액상세포검사와 고식적 방법의 비교)

  • Lee, Sun;Park, Jung-Hee;Do, Sung-Im;Kim, Youn-Wha;Lee, Ju-Hie;Chang, Sung-Gu;Park, Yong-Koo
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2007
  • Urine cytology is an important screening tool for urinary tract neoplasms. Liquid-based preparation methods, such as $ThinPrep^{(R)}$, have been introduced for non-gynecological samples. We aimed to assess the diagnostic accuracy of liquid-based preparations in urine cytology by comparing the results of the conventional Cytospin preparation method for the same samples. A total of 236 cases subject to urine cytology were enrolled in this study from January 2005 to December 2005. All cases were subjected to cystoscopy and if a malignancy was suspected, a biopsy was performed. Urine cytology slides were made using the $ThinPrep^{(R)}$ preparation method and the conventional Cytospin and/or direct smear method from the individual samples. The results of urine cytology were compared with the final cystoscopic or histological diagnoses. We analyzed the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of both cytology preparation methods. A total of 236 slides made using the liquid based method were satisfactory for slide quality, whereas 5 slides (2.1%) prepared by conventional methods were unsatisfactory because of air-drying, a thick smear, or a bloody or inflammatory background. The $ThinPrep^{(R)}$ method showed 53.1% sensitivity, 92.6% specificity, a 92,6% positive predictive value, a 94.1% negative predictive value and 85,6% accuracy, while the conventional method showed 51% sensitivity, 98.4% specificity, a 92.6% positive predictive value, a 98.4% negative predictive value and 88,6% accuracy. Although the diagnostic values were equivalent between the use of the two methods, the quality of the cytology slides and the time consumed during the microscopic examination for a diagnosis were superior for the $ThinPrep^{(R)}$ method than for the conventional method. In conclusion, our limited studies have shown that the use of the liquid based preparation method is beneficial to improve the quality of slides and reduce the duration for a microscopic examination, but did not show better sensitivity, accuracy and predictive values.

Synthesis of 3-D spatial matched filter for real-time 3-D image display (실시간 입체 영상 디스플레이를 위한 3차원 공간정합 필터의 합성)

  • 임선호;김은수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.8
    • /
    • pp.62-70
    • /
    • 1997
  • In this paper, we presetn a new method to display 3-D image modelled as a sum of 2-D sliced images by expanding the concept of the conventional 2-D optical correlator based on spatial matched filtr to the 3-D region. It is hsown that a arbitrary image can be constructed by an array of the correlation-peaks between pixel-to-pixel and propose the systhesis precedure of 3-D spatial-matched-fjilter using fresnel diffraction equation to display 3-D image in space. It is also shown that the quantization problem is severe when the systehsised filter function is displayed on the conventional LC-SLM. To overcome this problem, anonlinear quantizaton method using the sigmoid function is suggested, and this method can reduce the bias and the loss of high spatial-frequency information, and improve the diffraction efficiency. Finally, the suggested method is tested by computer simulation and then approved by some optical experiments with the conventional LC-SLM.

  • PDF

A natural frequency sensitivity-based stabilization in spectral stochastic finite element method for frequency response analysis

  • Lee, Gil-Yong;Jin, Seung-Seop;Park, Yong-Hwa
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.311-325
    • /
    • 2020
  • In applying the spectral stochastic finite element methods to the frequency response analysis, the conventional methods are known to give unstable and inaccurate results near the natural frequencies. To address this issue, a new sensitivity based stabilized formulation for stochastic frequency response analysis is proposed in this paper. The main difference over the conventional spectral methods is that the polynomials of random variables are applied to both numerator and denominator in approximating the harmonic response solution. In order to reflect the resonance behavior of the structure, the denominator polynomials is constructed by utilizing the natural frequency sensitivity and the random mode superposition. The numerator is approximated by applying a polynomial chaos expansion, and its coefficients are obtained through the Galerkin or the spectral projection method. Through various numerical studies, it is seen that the proposed method improves accuracy, especially in the vicinities of structural natural frequencies compared to conventional spectral methods.

CNN based IEEE 802.11 WLAN frame format detection (CNN 기반의 IEEE 802.11 WLAN 프레임 포맷 검출)

  • Kim, Minjae;Ahn, Heungseop;Choi, Seungwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.2
    • /
    • pp.27-33
    • /
    • 2020
  • Backward compatibility is one of the key issues for radio equipment supporting IEEE 802.11, the typical wireless local area networks (WLANs) communication protocol. For a successful packet decoding with the backward compatibility, the frame format detection is a core precondition. This paper presents a novel frame format detection method based on a deep learning procedure for WLANs affiliated with IEEE 802.11. Considering that the detection performance of conventional methods is degraded mainly due to the poor performances in the symbol synchronization and/or channel estimation in low signal-to-noise-ratio environments, we propose a novel detection method based on convolutional neural network (CNN) that replaces the entire conventional detection procedures. The proposed deep learning network provides a robust detection directly from the receive data. Through extensive computer simulations performed in the multipath fading channel environments (modeled by Project IEEE 802.11 Task Group ac), the proposed method exhibits superb improvement in the frame format detection compared to the conventional method.