• Title/Summary/Keyword: construction practice

Search Result 1,083, Processing Time 0.025 seconds

Recommended Practice on the Precautinary System and Installation to prevent electrical fire from reoccurring in underground tunnel (지하구조물내 전기재해 방지를 위한 설치지침 및 예방시스템 구축)

  • Kim, Se-Dong;Kim, Young-Jin;Kang, Jae-Mo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.337-341
    • /
    • 2005
  • Most utiltity systems are subject to frequent changes, often due to increased loads and demand to up-grade quality of service provided. Urban renewal, expressway construction and suburban growth have also caused significant changes in urban utility distribution systems. Recently, it is required that a guideline for planning of a complete system, the reasonable design and construction methods for the efficient installation common utility tunnels must be estabilished. It prompts drastic measures to guard cities and their inhabitants against the horror of massive fires in the future. Preparedness holds the key to safety.

  • PDF

Prevention of Soil Contamination from Underground Storage Facilities (유류저장시설로 인한 토양오염 예방대책)

  • 배우근;홍종철;정진욱;강우재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

A Study on the Improvement of BIM Education Programs -Focused on the Industry and Public Organizations- (BIM 전문 인력의 필요역량 도출을 통한 국내 BIM 교육의 개선방향 -국내 산업체 및 공공기간을 중심으로-)

  • Seo, Jung-Ho;Seo, Hee-Chang;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.221-224
    • /
    • 2010
  • The introduction of BIM-based project has increased in the domestic recently. Therefore the demand of BIM professionals is surging combined with the necessity of BIM education. However BIM education done in the domestic industry and public organization is only focusing on the 3D modeling, As a result an educatee could not put the real intention of BIM into practice. Thus through this study the wrong recognition of BIM will be corrected and this study analyzes the problems of domestic BIM-based project. This study examines the improvement of domestic BIM education cases by drawing the capability of BIM professionals.

  • PDF

Case Study for Developing of Standard Process about Defect Consulting Work in Apartment Building (공동주택 하자감정업무 표준절차개발을 위한 사례분석)

  • Park, Jun-Mo;Seo, Deok-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.158-159
    • /
    • 2014
  • There is urgent for defect consulting work to standardize the investigated method, repaired and reinforced method, and estimated cost about defect in increasing a defect lawsuit of apartment building. For the purpose of developing the standard process of defect consulting work, the review that a used process in law and institution should take precedence. There is not prepared the national standard for defect consulting but is dependent on an experience and a practice of consultants. This study analyzes defect consulting case, defines main steps for developing the standard process, and draws phased work factors. As systemizing this, it is expected to apply to basic structure for developing the standard process of defect consulting work for the next.

  • PDF

A Case Study on the Measurement and Estimation of Bearing Capacity of Large Diameter Bored Pile (대구경 현장타설말뚝의 지지력 측정 사례연구)

  • 이원제;정훈준;이우진;장기수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.285-292
    • /
    • 2000
  • Though there has been increasing use of large diameter drilled shaft as a foundation structure of bridges, current practice for quality control is to confirm the minimum required load carrying capacity during construction stage. For economic and appropriate design of drilled shaft, it is necessary to evaluate the load transfer mechanism by pile load tests during initial stage of construction and to use the test results as a feedback to a revision of initial design. In this paper, results of load tests peformed at several domestic sites are presented to investigate the load transfer characteristics of large diameter drilled shaft. It was found that most of the load on piles is sustained by shaft friction and that only small portion of the load reaches the bottom of the drilled shaft. Some test results of drilled shaft by Pile Driving Analyzer performed at same sites are also presented to compare the load transfer characteristics interpreted from static pile load tests.

  • PDF

The Mock-up Test of the Exposed Concrete by Applying the Flowing Concrete Method (유동화 공법을 적용한 노출 콘크리트 배합의 현장적용성에 관한 Mock-up Test)

  • Son, Ho-Jung;Park, Kyung-Taek;Hong, Seak-Min;Oh, Ch-Hyun;Han, Cheon-Goo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.165-167
    • /
    • 2011
  • This study is to evaluate the feasibility of the mix design for exposed concrete. Mock-up sized specimens were prepared, and a flowing concrete method was selected for placement. Results showed that the fluidity and air content of fresh concrete achieved target values, the compressive strength at 7 days was 27 MPa, and surface roughness was in the range of between around 1.53 and 1.68 ㎛, which was in the quality level. Therefore it is concluded that the proposed mix design for exposed concrete can be applied in practice.

  • PDF

Temperature History of Wall Concrete with Heat Insulating Curing Method Subjected to Severly Cold Climate (혹한온도 조건에서의 양생방법 변화에 따른 벽체 콘크리트의 온도이력 특성)

  • Son, Ho-Jung;Han, Sang-Yoon;Cheong, Sang-Hyeon;Ahn, Samg-Ku;Han, Cheon-Goo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.51-52
    • /
    • 2011
  • This study is to propose a curing method for a concrete wall structure under severe cold climate. The curing methods of using heated cable, heated panel and insulated form were applied. Results showed that the concrete cured by the heated cable resulted in the highest temperature history and the highest strength development at 28 days. Further, it is believed that the curing methods of the heated panel and insulated form are also recommendable for the resistance of the early frost damage on the concrete in practice.

  • PDF

Construction and roles of computer simulator for digital controller design

  • Nakamura, Masatoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.909-914
    • /
    • 1988
  • The structure of a digital controller based on modern control theory is more complex than that of a PID controller. In implementing the digital control of an actual system by using the digital controller, we often encounter gaps between theory and practice e.g. quantization error, sampling error, modeling error, contaminated noise etc. In such cases, simulator plays an important role in detecting difficulties. This paper demonstrates the importance of the computer simulator for designing a digital controller. The controller and the simulator are constructed by different computer respectively, with a link between the blocks by analogue signals through the A/D, D/A converters. Through the simulator test, we can evaluate the digital controller; identify and solve difficulties in the digital control. The controller, which pasted the simulator test, is used identically in the actual system. This was a successful procedure for designing the controller. As an example, we successfully constructed the digital controller using the computer simulator for inverted pendulum control. We then compared the control results of simulator and actual equipment. Furthermore we commented on the construction of the computer simulator which exactly expressed the actual system.

  • PDF

A Study on A-formal in Furniture Design Form Creation (가구디자인 형태창출에 있어서 비정형에 관한 연구)

  • Kim, Young Ho
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.4
    • /
    • pp.301-313
    • /
    • 2015
  • This study purposes on continuing experimental research of furniture form creation focused on the importance and necessity for a-formal concept for designers to drift away from general acknowledgement and practice routine to design more radical forms for meeting various needs of late industrialized society, which have not been satisfied with formal and universal designs. This study covers presenting new points of view on research for designers to look for different solutions to widen their consideration in the process of furniture form development and to set up academic data base with the case studies of designers in anti-construction concept to define their experimental challenges for new design form creation, on the basis of overall research on the effects and roles of a-formal approach in the furniture design form creation.

On the problem and improvements about 'End of Confirmation for Defect Liliability' on the Management of Apartment Houses Decree (공동주택관리법 하자담보책임 종료 확인 절차의 문제점 및 개선방안)

  • Kim, Jin-Kuk;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.274-275
    • /
    • 2017
  • Decree on the Management of Apartment Houses. Article 36 (Liability for warranty Repair Defects), Article 37 (About Repair Defect, etc), and its implementing ordinances, Article 36 (Term of warranty liability) Article 37 (Defect criteria), Article 38 (procedure of Repair defect), Article 39 (type of warranty liability), Enforcement Rule Article 17 (Certifiation of warranty liability). On the basis of the upper Decree, In spite of Standard and forms of 'Completion of Repair Defect' was exist, it was hard to receive 'End of Confirmation' in practice. The purpose of this study is to propose basics in order that Practitioners can apply problems and improvements about Decree on the Management of Apartment Houses.

  • PDF