• Title/Summary/Keyword: connection failure

Search Result 614, Processing Time 0.027 seconds

Soft Interconnection Technologies in Flexible Electronics (플렉시블 전자소자의 유연전도성 접합 기술)

  • Lee, Woo-Jin;Lee, Seung-Min;Kang, Seung-Kyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2022
  • Recent necessities of research have emerged about soft interconnection technologies for stable electric connections in flexible electronics. Mechanical failure in conventional metal solder interconnection can be solved as soft interconnections based on a small elastic modulus and a thin thickness. To enable stable electric connection while improving mechanical properties, highly conductive materials be thinned or mixed with a material that has a small elastic modulus. Representative soft interconnection technologies such as thin-film metallization, flexible conductive adhesives, and liquid metal interconnections are presented in this paper, and be focused on mechanical/electric properties improving strategies and their applications.

Study of Necessity of Advanced Integrated Digital Engineering and Management Tools (선진통합형 디지털 엔지니어링 및 경영 도구의 필요성 연구)

  • Luke (Yang Ouk) Kim;Kyung Ho Lee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.1
    • /
    • pp.27-38
    • /
    • 2023
  • How the port, shipping, shipbuilding, and vender industries in Korea can have a seamless value chain through their digitally smooth cooperation by applying the latest information and communications technology through the "4th industrial revolution" was examined. Also considered was the proposition that the value chain should be a smart, seamless value chain among industries with successful hyperconnection. Their cooperative relationships were defined, and the crucial elements for the sustainable development of these industries were considered. As a result, the direction for achieving environmental, social, and governance management by realizing decarbonization through today's digitalization could be studied. In particular, the importance of digitization as a way to respond to the future market from the perspective of small and medium-sized enterprises and the role of digitization realized by small and medium-sized equipment companies in the overall industry were examined. The results simultaneously show the state of linkage between industries and the reason why the value chain must maintain a smooth relationship. In addition, using the lessons learned from recent failure cases from the Korean shipbuilding industry as a cornerstone, the direction for creating a strategic pathway for intelligent connection was investigated.

Implementation of a KPI Focused e-QMS: A Case Study in the Aerospace & Defense Industry (KPI 중심의 e-QMS 구현: 우주항공 및 방위 산업 사례 연구)

  • Jae Young Shin;Wan Seon Shin
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.1
    • /
    • pp.131-154
    • /
    • 2023
  • Purpose: The purpose of this paper is to design an integrated informatization system that can manage quality & KPI by integrating management systems in the aerospace and defense industry, and study the effect on KPI when applied to related companies. Methods: The 7 management systems required for integration in the AS&D industry were studied, and an empirical analysis was conducted for H company in South Korea for the application of e-QMS integrated informatization & KPI system based on security environment and open quality. Results: The results of this study were analyzed to have an effect on the improvement of customer satisfaction and the positive improvement of quality failure cost in the aerospace and defense industry. And it was analyzed that it works to continuously comply with ethical management and environmental laws and prevent safety accidents. Conclusion: The greatest significance of this study is that it attempted to build an e-QMS integrated system in the aerospace and defense industry. Considering that the case of integrated management system and integrated operation of KPI in related industries has not been introduced in the existing literature, the results of this study will be shared as a meaningful preceding study in the era of digital quality information. In addition, the fact that the open-quality quality innovation methodology emphasizing measurement(M), tracking(T), and connection(C) was actually applied in an AS&D company and its effectiveness was objectively proven. It is expected that it will be a good paper for follow-up research.

Evaluation of Bending Creep Performance of Laminated Veneer Lumber (LVL) Formwork for the Design of Timber Concrete Composite (TCC) Structures

  • Hyun Bae KIM;Takuyuki YOSHIOKA;Kazuhiko FUJITA;Jun ITO;Haruka NOHARA;Keiji NOHARA;Toshiki NARITA;Wonwoo LEE;Arata HOSOKAWA;Tetsuiji TANAKA
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.375-382
    • /
    • 2024
  • The study focuses on evaluating the bending creep performance of laminated veneer lumber (LVL) formwork in timber concrete composite (TCC) structures. Timber-framed construction is highlighted for its environmental benefits and seismic resistance, but limitations such as poor tensile strength and brittle failure in bending hinder its use in high-rise buildings. Wood-concrete hybrid structures, particularly those using reinforced concrete slabs with TCC floors, emerge as a potential solution. The research aims to understand the time-dependent behavior of TCC components, considering factors like wood and concrete shrinkage and connection creep. The experiment was conducted in western Japan on the TCC floor designed for use in the Kama-city Inatsuki-higashi compulsory education school. The LVL formwork, measuring 9,000 mm by 900 mm, and concrete is loaded onto it for testing. The creep test periods are examined using concrete loading. It employs a comprehensive creep analysis, adhering to Japanese standards, involving deflection measurements and regression analysis to estimate the creep coefficient. Results indicate substantial deformation after shoring removal, suggesting potential reinforcement needs. The study recommends extending test periods for improved accuracy and recognizing regional climate impacts. Overall, the research provides valuable insights into the potential of LVL formwork in TCC structures, emphasizing safety considerations and paving the way for further experimentation under varied conditions to validate structural integrity.

Effect of RBS on seismic performance of prefabricated steel-concrete composite joints

  • Zhen Zhu;Haitao Song;Mingchi Fan;Hao Yu;Chenglong Wu;Chunying Zheng;Haiyang Duan;Lei Wang
    • Steel and Composite Structures
    • /
    • v.52 no.4
    • /
    • pp.405-418
    • /
    • 2024
  • To study the influence of different reduced beam section (RBS) on the mechanical performance of modular boltedwelded hybrid connection joints (MHCJs), this article uses ABAQUS to establish and verify the finite element model (FEM) of the test specimens on the basis of quasi-static test research. Based on, 14 joint models featuring different RBS are devised to evaluate their influence on seismic behavior, such as joint failure mode, bending moment (M)-rotation angle (θ) curve, ductility, and energy consumption. The results indicate that when the flange and web are individually weakened, they alleviate to some extent the concentrated stress of the core module (CM) and column end steel skeleton in the joint core area, but both increase the stress on the flange connecting plate (FCP). At the same time, the impact of both on seismic performance such as bearing capacity, stiffness, and energy consumption is relatively small. When simultaneously weakening the flange and web of the steel beam, forming plastic hinges at the weakened position of the beam end, significantly alleviated the stress concentration of the CM and the damage at the FCP, improving the overall deformation and energy consumption capacity of joints. But as the weakening size of the web increases, the overall bearing capacity of the joint shows a decreasing trend.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.

The risk factors for implant survival and marginal bone loss: a retrospective long-term study (임플란트 장기간 유지와 변연골 소실에 영향을 주는 요인들에 대한 후향적 연구)

  • Lee, Eun-Woo;Jung, Ha-Na;Jo, Yujin;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.97-109
    • /
    • 2022
  • Purpose: This study aims to investigate the risk indicators contributing to implant failure, and analyze the relationship between risk indicators and marginal bone loss (MBL) through long-term follow-up over 3 years. Materials and Methods: From 2003 to 2017, patients' medical charts with a history of dental implant surgery at Chonnam National University Dental Hospital were reviewed retrospectively. The patient's demographic variables, and clinical variables were recorded. Periapical radiographs were used to evaluated the changes in MBL around implants. And we analyzed implant survival rates. Multiple regression analysis with backward elimination was conducted to correlate the patient's clinical variables and implant failure and Pearson correlation analysis was performed to the correlated between implant long-term survival rates and MBL and initial stability. Results: In multiple regression analysis, there was a statistically significant negative correlation between abutment connection type (β = -.189, P < .05), with or without SPT (β = -.163, P < .05), diabetes (β = -.164, P < .05), osteoporosis (β = -.211, P < .05) and MBL. Anticoagulant medication influenced the long-term success rate of implants. PTV values at the second implant surgery showed a statistically significant negative correlation with long-term implant survival (P < .05). Conclusion: For the long-term success of the implant, the appropriate abutment connection type must be selected and the periodic SPT is recommended. Systemic diseases such as diabetes and osteoporosis and anticoagulant medication should be considered. Furthermore, since high PTV at the second implant surgery correlated with the long-term survival rates of the implant, initial stability should be carefully considered before undergoing the prosthetic procedure.

Surgical Results and Risk Facor Analysis of the Patients with Single Ventricle Associated with Total Anomalous Pulmonary Venous Connection (총폐정맥연결이상증을 동반한 단심증 환아의 수술결과 및 위험인자 분석)

  • 이정렬;김창영;김홍관;이정상;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.862-870
    • /
    • 2002
  • The surgical results of the patients with single ventricle(SV) associated with total anomalous pulmonary venous connection(TAPVC) has been reported with high mortality and morbidity due to their morphologic and hemodynamic complexity. A retrospective review was undertaken to report the outcome of the first-stage palliative surgery in our institution and to determine the factors influencing early death. Material and Method: Between January 1987 and June 2002, 39 patients with SV and TAPVC underwent surgical intervention with or without TAPVC repair. Age at operation ranged from 1day to 10.7months (median age, 2.4month), and 29 patients were male. Preoperative diagnosis included 20 right-dominant SV, 15 SV with endocardial cushion defect, 3 left-dominant SV, and 1 tricuspid atresia. The pulmonary venous connection was supracardiac in 22, cardiac in 5, infracardiac in 11, and mixed in 1, Obstructed TAPVC was present in 11. First-stage palliative surgery was performed in 37. Repair of TAPVC, either alone or in association with other procedures, was performed during the initial operation in 31. Univariate and multivariate analyses were performed to analyze the risk factors influencing the operative death. Result: A mean follow-up period of survivors was 34.3 $\pm$ 43.0(0.53 ~ 146.2)months. Overall early operative mortality was 43.6%(17/39). The causes were low cardiac output in 8, failure of weaning from cardiopulmonary bypass in 3, sepsis in 2, pulmonary hypertensive crisis in 1, pulmonary edema in 1, pneumonia in 1, and postoperative arrhythmia in 1. Risk factors influencing early death in univariate analysis were body weight, surgical intervention in neonate, obstructive TAPVC, preoperative conditions including metabolic acidosis, and need for inotropic support, TAPVC repair in initial operation, operative time, and cardiopulmonary bypass(CPB) time. In multivariable analysis, body weight, age at initial operation, surgical intervention in neonate, preoperative conditions including metabolic acidosis, need for inotropic support and CPB time were the risk factors. Conclusion: In this study, we demonstrated that the patients with SV and TAPVC had high perioperative mortality. Preoperative poor condition, young age, the length of operative and CPB time, the presence of obstructive TAPVC had been proven to be the risk factors. This fact suggests that the avoidance of unnecessarily additional procedures may improve the surgical outcomes of the first-stage palliative surgery. However further observation and collection of the data is mandatory to determine the ideal surgical strategy.

Mid-term results of IntracardiacLateral Tunnel Fontan Procedure in the Treatment of Patients with a Functional Single Ventricle (기능적 단심실 환자에 대한 심장내 외측통로 폰탄술식의 중기 수술성적)

  • 이정렬;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.472-480
    • /
    • 1998
  • We reviewed the surgical results of intracardiac lateral tunnel Fontan procedure for the repair of functional single ventricles. Between 1990 and 1996, 104 patients underwent total cavopulmonary anastomosis. Patients' age and body weight averaged 35.9(range 10 to 173) months and 12.8(range 6.5 to 37.8) kg. Preoperative diagnoses included 18 tricuspid atresias and 53 double inlet ventricles with univentricular atrioventricular connection and 33 other complex lesions. Previous palliative operations were performed in 50 of these patients, including 37 systemic to pulmonary artery shunts, 13 pulmonary artery bandings, 15 surgical atrial septectomies, 2 arterial switch procedures, 2 resections of subaortic conus, 2 repairs of total anomalous pulmonary venous connection and 1 Damus-Stansel-Kaye procedure. In 19 patients bidirectional cavopulmonary shunt operation was performed before the Fontan procedure and in 1 patient a Kawashima procedure was required. Preoperative hemodynamics revealed a mean pulmonary artery pressure of 14.6(range 5 to 28) mmHg, a mean pulmonary vascular resistance of 2.2(range 0.4 to 6.9) wood-unit, a mean pulmonary to systemic flow ratio of 0.9(range 0.3 to 3.0), a mean ventricular end-diastolic pressure of 9.0 (range 3.0 to 21.0) mmHg, and a mean arterial oxygen saturation of 76.0(range 45.6 to 88.0)%. The operative procedure consisted of a longitudinal right atriotomy 2cm lateral to the terminal crest up to the right atrial auricle, followed by the creation of a lateral tunnel connecting the orifices of either the superior caval vein or the right atrial auricle to the inferior caval vein, using a Gore-Tex vascular graft with or without a fenestration. Concomitant procedures at the time of Fontan procedure included 22 pulmonary artery angioplasties, 21 atrial septectomies, 4 atrioventricular valve replacements or repairs, 4 corrections of anomalous pulmonary venous connection, and 3 permanent pacemaker implantations. In 31, a fenestration was created, and in 1 an adjustable communication was made in the lateral tunnel pathway. One lateral tunnel conversion was performed in a patient with recurrent intractable tachyarrhythmia 4 years after the initial atriopulmonary connection. Post-extubation hemodynamic data revealed a mean pulmonary artery pressure of 12.7(range 8 to 21) mmHg, a mean ventricular end-diastolic pressure of 7.6(range 4 to 12) mmHg, and a mean room-air arterial oxygen saturation of 89.9(range 68 to 100) %. The follow-up duration was, on average, 27(range 1 to 85) months. Post-Fontan complications included 11 prolonged pleural effusions, 8 arrhythmias, 9 chylothoraces, 5 of damage to the central nervous system, 5 infectious complications, and 4 of acute renal failure. Seven early(6.7%) and 5 late(4.8%) deaths occured. These results proved that the lateral tunnel Fontan procedure provided excellent hemodynamic improvements with acceptable mortality and morbidity for hearts with various types of functional single ventricle.

  • PDF