• Title/Summary/Keyword: connecting

Search Result 3,824, Processing Time 0.034 seconds

The Causes and Analysis of Electrical Fires -focused on Dynamic Characteristics of RCD- (전기화재의 발생원인 및 분석 -누전차단기의 동작특성을 중심으로-)

  • 이상호
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • Recently, the occurrences of electrical fire have been suppressed by a residual current protective devices(RCD), a molded case circuit breaker(MCCB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the RCD to break the circuit in the case of the conductor fractures, the failure of pressure contacts on connecting points and the momentary short circuit of low voltage wiring. Therefore, it is require to study the constructive problem of the RCD. In this paper, we have tested the operation characteristics of the RCD according to the R load and R-L load in the conductor fractures, the failure of pressure contacts on connecting points and the momentary short circuit of low voltage wiring.

Virtual Topology Reconfiguration Algorithm for Implementing the WDM-based Cluster (WDM-기반의 클러스터 구현을 위한 가상 토폴로지 재구성 알고리즘)

  • Park Byoung-Seob
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.9
    • /
    • pp.9-18
    • /
    • 2006
  • We completed a new cluster system based on WDM by proposing a virtual topology reconfiguration schemes. The key idea of the proposed scheme is to construct a set with the longest chains of requests of connecting nodes which need to be assigned a wavelength. All the sets have no common factor, that is, there is no duplicated link among the requests of connecting. After making the set satisfying this condition, we could assign a wavelength to per corresponding set. We could reconfigure a virtual topology with this scheme collectively. we compared our scheme to existing approaches by the OWns simulation tool. As the results, we gained improved performances, reducing 10% of blocking rate and improving 30% of ADM utilization in terms of the blocking probability and the ADM utilization.

  • PDF

A Study on the Minimum Oil Film Thickness of Connecting-rod Bearing in Engine (엔진 연결봉 베어링의 최소 유막 두께에 관한 연구)

  • Choi, Jae-Kwon;Heo, Gon;Han, Dong-Chul
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1993.04a
    • /
    • pp.39-53
    • /
    • 1993
  • The minimum oil film thickness(MOFT) in the connecting-rod bering of a 1.5 liter, L-4, gasoline engine is measured up to 5500 rpm and calculated to study the dynamically loaded engine bearing. Short bearing approximation and Mobility method are used for theoretical analysis of oil film charactrtistics. And cylinder pressure, crank-pin surface temperature and bearing tenp ture are measured as the input data of theoretical analysis. The MOFT are measured by the total capacitance method(TCM). To improve the reliability of the test results, a reasonable detmuuination method of bearing clearance is introduced and used, and the effects of cavitation and aeration on the test results are neglected. The crankshaft is grounded by means of a slip ring. A scissor type linkage system was developed to measure the MOFT and bearing temperature. The effects of engine speed, load and oil viscosity on the measured and calculated minimum oil film thicknesses are investigated at 1500 to 5500 rpm. From the comparison between the measured and calculated MOFT, it is found that a qualitative similarity exists between them, but in all cases, the measured MOFT are smaller than those calculated.

  • PDF

Surgical Repair of Rostral Hemimandibular Fractures with Canine Tooth Luxation in a Dog (개에서 견치 탈구를 동반한 앞쪽 하악골 골절의 수술적 정복 1례)

  • Yoon, Hun-Young;Kang, Myung-Gon;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.359-361
    • /
    • 2009
  • A sexually intact female Alaskan Malamute, 5-year-old weighing 25.2 kg presented to the Hangang Animal Hospital, following hit-by-car. On initial presentation, the dog had severe salivation and the right canine tooth luxation. Radiographs revealed fractures of the right rostral hemimandible with the right canine tooth luxation and symphyseal separation. Surgical repair of fractures was performed by use of an interdental wiring technique and external fixation technique that included pins, an acrylic connecting bar, and polymethyl methacrylate bone cement. Post-operative radiographs revealed that bridging callus was well formed over cortices of the fracture area. Pins and an acrylic connecting bar were removed 7 weeks post-operatively. The dog exhibited evidence of normal mastication.

A Novel Transversal Filter using Triple-Coupled-Line Directional Couplers (삼중 결합선로 방향성결합기를 이용한 새로운 구조의 트랜스버살 필터)

  • 지기만;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.6
    • /
    • pp.591-598
    • /
    • 2003
  • A novel transversal filter using triple-coupled-line directional couplers is proposed. Simple design method which uses sinc function for computing coupling coefficients of the proposed transversal filter are also introduced. The frequency characteristics of the proposed filter are seldom degraded by the connecting sections between the cascaded directional couplers while those of the conventional transversal filter are aggravated. Moreover, the less number of the connecting sections and the directional couplers is required in the proposed filter than fer the case of the conventional transversal filter having the same bandwidth. The performance of the proposed transversal filter is verified by measurement and the measured results are compared with the calculated results.

Wireless Measurement Technology for Power Plant Performance Diagnosis (발전설비의 성능진단 적용 무선계측 기술)

  • Kim, Ui-Hwan;Lee, Eung-Gon;Hong, Eun-Gi
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • The performance test is conducted for the purpose of determining the accurate thermal performance of the power generation facility or deriving the factors of thermal efficiency degradation. Compared to the acquisition method of power plant thermal performance test data by compensating cable or transmission cable, performance test using wireless instrument can acquire digital data in order to shorten the period due to installation and demolition of instrument and enhance safety of workers and relatively accurate data can be acquired thereby improving work efficiency. Wireless instruments have already been introduced to the market a long time ago, and some of them are used in industry such as petrochemical industry. However, there is no example which has been conducted for performance test of power generation facilities. In order to apply power generation facilities, a reliable system capable of acquiring performance data smoothly without affecting the control system is required. The wireless measurement system can eliminate the measurement defects and errors such as the damage due to the movement of the connecting cable, the extension due to the extension of the shield wire, the contact failure at the contact point between the measuring sensor and the connecting wire, This method has the advantage of collecting relatively accurate performance test data.

Parameter Identification of a Synchronous Reluctance Motor by using a Synchronous PI Current Regulator at a Standstill

  • Hwang, Seon-Hwan;Kim, Jang-Mok;Khang, Huynh Van;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.491-497
    • /
    • 2010
  • This paper proposes an estimation algorithm for the electrical parameters of synchronous reluctance motors (SynRMs) by using a synchronous PI current regulator at standstill. In reality, the electrical parameters are only measured or estimated in limited conditions without fully considering the effects of the switching devices, connecting wires, and magnetic saturation. As a result, the acquired electrical parameters are different from the real parameters of the motor drive system. In this paper, the effects of switching devices, connecting wires, and the magnetic saturation are considered by simultaneously using the short pulse and closed loop equations of resistance and synchronous inductances. Therefore, the proposed algorithm can be easily and safely implemented with a reduced measuring time. In addition, it does not need any external or additional measurement equipment, information on the motor's dimensions, and material characteristics as in the case of FEM. Several experimental results verify the effectiveness of the proposed algorithm.

Stress Analysis of Pipe Connection Process Using Clamping Ring (구속 링을 이용한 관 결합 공정의 응력해석)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.81-87
    • /
    • 2017
  • The pipe connection process using a clamping ring is used for joining small pipes in the refrigerator and air-conditioner industries instead of the brazing process, which induces inevitable thermal deformation in the pipes. However, few studies have been carried out on the process to select optimal parameters in joining pipes, and studies on the relation between the process parameters of the connection and connecting force of the joint have not been conducted. In this study, the connection process of pipes with the clamping ring was modeled using the finite element method (FEM) and analyzed to obtain the contact stress distribution between the pipes with which the connecting force of the joint was estimated. Considering the characteristics of pipe connection, the process was modeled and simulated in a two-dimensional axisymmetric solution domain. With the numerical model, the effect of ring shape on the connection was studied by adding a projection to the end of a ring or changing the length of a ring. The results of the analyses revealed that the contact stress distribution could be predicted with the suggested model. The effect of the ring shape was also presented. The effect of any combination of process parameters could be easily estimated through the related analyses.

Network Connecting Structure and Contextual Meanings of Chungbuk Innovation Projects Based on the Amalgamation of Social Network Analysis and System Dynamics Approaches (SNA와 SD 방법론을 활용한 충북 지역혁신사업의 네트워크 연결구조와 함의)

  • Lee, Mi-Ra;Hong, Seong-Ho;Park, Ju-Hye;Lee, Man-Hyung
    • Korean System Dynamics Review
    • /
    • v.10 no.2
    • /
    • pp.103-120
    • /
    • 2009
  • Using various data derived from the regional innovation projects in the IT and BT-sectors within Chungbuk Province, this study tries to observe formation processes of network connecting structure and their spill-over effects. Considering the dynamic nature of key issues, it applies both social network analysis and causal loop methods. After a series of simulation exercises, we find that so-called extroverted regional innovation projects, that is, ones financially supported by the central government, reveal a higher tendency in the centrality, heavily depending on a handful of well reputed organizations. It is quite similar to the reinforcing mechanism, resulting in the rich-get-richer and the poor-get-poorer. Compared with the existing documents, nonetheless, it shows relatively weak in the mechanism strength, implying the fact that regional innovation projects have significantly contributed to ameliorating the unequal distribution of innovation organizations within Chungbuk Province. On the other hand, this study concludes that all the brokerage organizations related to the regional innovation projects have settled in Chungbuk Province. Whereas the Capital Region-based organizations present a higher tendency in the knowledge-network, it seems that the regional innovation projects have significantly contributed to upgrading direct and indirect competitiveness of the local organizations.

  • PDF

Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring (조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.