• Title/Summary/Keyword: conformity test

Search Result 318, Processing Time 0.02 seconds

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF

The Effects of the Change of Operating Income Disclosure Policy under K-IFRS - Evidence from KOSDAQ Market - (K-IFRS 이후 영업이익 공시정책의 변화에 대한 연구 - 코스닥 시장을 중심으로 -)

  • Baek, Jeong-Han;Choi, Jong-Seo
    • Management & Information Systems Review
    • /
    • v.33 no.3
    • /
    • pp.167-187
    • /
    • 2014
  • While Korean GAAP had detailed regulations for the measurement and disclosure of operating income in the past, K-IFRS did not provide specific rules for operating income until 2011. Some firms that adopted K-IFRS before 2011 did not disclose or calculated operating income in an inconsistent manner although operating income is usually considered as one of the core information items to assess firm valuation. Inconsistency in firms' treatment of operating income invoked much criticism from diverse users of financial statement. The Korean Accounting Institute (KAI hereafter) revised the K-IFRS rules relevant to operating income in September 2010 in response to the voices raised by the business community, whereby the operating income number is allowed to be calculated in conformity with the previous K-GAAP. This study was motivated by the revision of K-IFRS and aims to provide a clue on the validity of such policy decision. To achieve the research objective, we test the relative value relevance of the alternative operating income numbers under K-IFRS versus K-GAAP. Our main findings are as follows. The value relevance of operating income reported before K-IFRS is proved to be higher than after K-IFRS. K-IFRS operating income adjusted to the previous K-GAAP has greater explanatory power for market values relative to one calculated under the K-IFRS regime. In an additional analysis, the sample was decomposed according to whether the operating income under K-IFRS is greater than under K-GAAP. The difference in the value relevance of K-IFRS versus K-GAAP operating income is significant only in the subsample consisting of firms which reports higher operating income under K-IFRS compared to K-GAAP. Also, the firms which would have reported negative operating income on a consecutive basis are more likely to have chosen K-IFRS, resulting in higher numbers than otherwise. It is likely that firms facing the threat of delisting due to consecutive operating loss reporting are more likely to have adopted K-IFRS disclosure rules by which they could report higher operating income numbers. To sum up, these results corroborate the limitation inherent in the K-IFRS regarding operating income disclosures. This paper suggests that the recent revision of K-IFRS implemented by KAI is likely to mitigate some of afore-mentioned limitations effectively.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

A Study on Secondary School Girl Students' Life Style, Attitude toward Appearance and Clothing Attitude (중.고등학교 여학생의 라이프스타일, 외모에 대한 태도와 의복태도와의 관련 연구)

  • Lee, Eun-Hee
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.4 s.42
    • /
    • pp.85-102
    • /
    • 2006
  • The objectives of this study were to classify of life style of secondary school girl students, to investigate the relationships between life styles, attitude toward appearance and clothing attitude. The method of this study was survey research by using questionnaires. Subjects were 658(middle school students 327, high school students 331) girl students located in Jeollabukdo province. In this statistical analysis, SPSS 11.5 for Windows program was utilized to calculate frequency, mean, cronbach's ${\alpha}$, factor analysis, t-test, Pearson's correlation, multiple regression analysis. The results of this research were as follows: The results of analysing the factors to the response lifestyles, attitude toward appearance and clothing attitude emerged five dimensions(digital orientation, material orientation, positive activity, achievement orientation, frugality), three dimensions(needs conformity value toward appearance), five dimensions(fashion pursuit, gender attractiveness, self-expression, aesthetic, and modesty). High school girls' students showed higher digital orientation and positive activity life styles, attitude toward appearance, clothing attitude except of modesty. Clothing attitude variables except of modesty had positive correlations with lifestyles and attitude toward appearance. However, modesty of clothing had negative correlations with life styles and attitude toward appearance. As a conclusion, secondary school girl students' life styles and attitude toward appearance constituted important characteristics which could affect clothing attitude directly.

  • PDF

Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior (인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 바닥판과 역T형 강재 합성보의 휨거동 해석)

  • Yoo, Sung-Won;Yang, In-Hwan;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.185-193
    • /
    • 2015
  • Ultra high performance concrete (UHPC) has been developed to overcome the low tensile strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.