• Title/Summary/Keyword: conformal

Search Result 774, Processing Time 0.02 seconds

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

Precision evaluation of the treatment that used coordinates confirmation of couch in case of two forgets adjoined. (Couch의 좌표 확인을 이용한 치료 위치 이동의 정확성 평가)

  • Seo Jeong-min;Jeong Cheon-young;Park Young-hwan;Song Ki-won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2003
  • I. Purpose Confirming an error to be able to break out in a method to move couch manually while operator sees the skin marks on patient in case of curing head who got 2 targets adjoined, so we analyze coordinates price of couch, evaluate reproducibility and precision of change movements between targets. II. Materials and Methods In radiotherapy, for confirming errors in manual movements by operators by exchanging between two targets to treat patient head, we read coordinates price(vertical, longitudinal, lateral three directions of couch) shown on a monitor of LINAC( CL 2100, Varian, USA) in order to evaluate accuracy about the length that moved in time for moving couch manually. After reading movement length of coordinates recorded in three directions of all treatment, we compared distance between targets recorded in RTP(Pinnacle, ADAC, USA) with reading coordinates price of couch, setting actually done the same patient for ten times, coordinates were recorded, treated for evaluating averages and degrees of errors and standard deviations. III. Results In method to confirm skin marks of patient by operators' view and to move couch manually, average standard deviations of movements between two targets are vertical 1.4mm, longitudinal 0.9mm, lateral 2.2mm in each direction. As for the error in straight dimension, it is about 3.6mm averages and 5.1mm maximum. The average of errors in each directions was vertical 1mm, longitudinal 0.7mm, lateral 2.7mm. The greatest error broke out in lateral direction with $25\%$ of all cases ; to exceed an error average. IV. Conclusions If operators moved manually couch for changing target points, errors about 3.6mm average degrees occur. It is important that operators confirm the errors prices of actual couch coordinates for asking a correct movement between the targets adjoined each other ; in case of treatment demanding high precision like 3D conformal therapy or IMRT. Therefore, if we apply couch coordinates confirmation to reproducibility and to precision evaluation of treatment, it's expected that we can execute high-quality radiotherapy.

  • PDF

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD) (전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가)

  • Lee, Joo-Ah;Back, Geum-Mun;Kim, Yeon-Soo;Son, Soon-Yong;Choi, Kwan-Woo;Yoo, Beong-Gyu;Jeong, Hoi-Woun;Jung, Jae-Hong;Kim, Ki-Won;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • This study is to provide basic information regarding photoneutron doses in terms of radiation treatment techniques and the number of portals in intensity-modulated radiation therapy (IMRT) by measuring the photoneutron doses. Subjects of experiment were 10 patients who were diagnosed with prostate cancer and have received radiation treatment for 5 months from September 2013 to January 2014 in the department of radiation oncology in S hospital located in Seoul. Thus, radiation treatment plans were created for 3-Dimensional Conformal Radiotherapy (3D-CRT), Volumetric-Modulated Arc Radiotherapy (VMAT), IMRT 5, 7, and 9 portals. The average difference of photoneutron dose was compared through descriptive statistics and variance analysis, and analyzed influence factors through correlation analysis and regression analysis. In summarized results, 3D-CRT showed the lowest average photoneutron dose, while IMRT caused the highest dose with statistically significance (p <.01). The photoneutron dose by number of portals of IMRT was $4.37{\pm}1.08mSv$ in average and statistically showed very significant difference among the number of portals (p <.01). Number of portals and photoneutron dose are shown that the correlation coefficient is 0.570, highly statistically significant positive correlation (p <.01). As a result of the linear regression analysis of number of portals and photoneutron dose, it showed that photoneutron dose significantly increased by 0.373 times in average as the number of portals increased by 1 stage. In conclusion, this study can be expected to be used as a quantitative basic data to select an appropriate IMRT plans regarding photoneutron dose in radiation treatment for prostate cancer.

A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer (비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구)

  • Yeom, Misuk;Lee, Woosuk;Kim, Daesup;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Purpose : For non-small cell lung cancer, if the treatment volume is large or the total lung volume is small, and the tumor is located in midline of patient's body, total lung dose tends to increase due to tolerance dose of spinal cord. The purpose of this study is to compare and evaluate the total lung dose of three dimensional conformal radiotherapy(3D CRT), intensity modulated radiotherapy(IMRT) and volumetric modulated arc therapy(VMAT) using restricted angle for non-small cell lung cancer patients. Materials and Methods : The treatment plans for four patients, being treated on TrueBeam STx($Varian^{TM}$, USA) with 10 MV and prescribed dose of 60 Gy in 30 fractions, 3D CRT, restricted angle IMRT and VAMT radiotherapy plans were established. Planning target volume(PTV), dose to total lung and spinal cord were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV, $V_{30}$, $V_{20}$, $V_{10}$, $V_5$, mean dose for total lung and maximum dose for spinal cord was assessed. Results : Average value of CI, HI and PCI for PTV was $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$ respectively. $V_{20}$ values from 3D CRT, IMRT and VMAT plans were 30.7%, 20.2% and 21.2% for the first patient, 33.0%, 29.2% and 31.5% for second patient, 51.3%, 34.3% and 36.9% for third patient, finally 56.9%, 33.7% and 40.0% for the last patient. It was noticed that the $V_{20}$ was lowest in the IMRT plan using restricted angle. Maximum dose for spinal cord was evaluated to lower than the tolerance dose. Conclusion : For non-small cell lung cancer, IMRT with restricted angle or VMAT could minimize the lung dose and lower the dose to spinal cord below the tolerance level. Considering PTV coverage and tolerance dose to spinal cord, it was possible to obtain IMRT plan with smaller angle and this could result in lower dose to lung when compared to VMAT.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).

Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy (국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료)

  • Choi Chul-Won;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Yoo Hyung-Jun;Lee Dong-Han;Ji Young-Hoon;Han Chul-Ju;Kim Jin;Kim Young-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.11-20
    • /
    • 2006
  • Puroose: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. Materials and Methods: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status ${\leq}3$ and locally advanced pancreas cancer without distant metastasis, evaluated by CT or PET/CT, were included. We administered stereotactic RT consisting of either 33 Gy, 36 Gy or 39 Gy in 3 fractions to 6, 4 and 9 patients, respectively, in an effort to increase the radiation dose step by step, and analyzed the survival rate and gastrointestinal toxicities by the acute radiation morbidity criteria of Radiation Therapeutic Oncology Group (RTOG). Prognostic factors of age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9, planning target volume (PTV), and adjacent organ and vessel invasion on CT scan were evaluated by Log Rank test. Results: The median survival time was 11 months with 1-year survival rate of 36.8%. During follow-up period (range $3{\sim}20$ months, median 10 months), no significant gastrointestinal acute toxicity (RTOG grade 3) was observed. In univariate analysis, age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9 level, and adjacent organ and vessel invasion did not show any significant changes of survival rate, however, patients with PTV (80 cc showed more favorable survival rate than those with PTV>80 cc (p-value<0.05). In multivariate analysis, age younger than 65 years and PTV>80 cc showed better survival rate. Conclusion: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.

Dosimetric comparison for Prostate VMAT of weight and photon energy change (전립선 암 입체적세기변조방사선치료 시 체형 및 에너지 변화에 따른 선량 평가)

  • Jo, Guang Sub;Kim, Min Woo;Baek, Min Gyu;Chae, Jong Pyo;Ha, Se Min;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.17-25
    • /
    • 2018
  • Purpose : To compare the radiation doses of prostate cancer patients according to changes in abdominal body shape and energy during Volumetric modulated arc therapy(VMAT). Materials and Methods : Seven patients with prostate cancer were enrolled in this study. VMAT treatment plan was established at 6, 10, and 15 MV while changing from -2.0 cm to 2 cm by 0.5 cm. Conformal index(CI), homogeneous index(HI), $D_{max}$, $D_{95%}$, $D_{50%}$ and $D_{2%}$ of PTV were examined in order to evaluate the change of dose in the target organ according to body shape change. Normal organ of the femoral head, rectum and bladder was analyzed to evaluate dose changes. Results : The dose of $D_{max}$ 6 MV in PTV increased to 107.2 % in 1.0 cm body shape reduction, and 10 MV and 15 MV dose increased to 107.1 % and 107.0 % in 1.5 cm body reduction, respectively. The dose of $D_{50%}$ 6 MV in PTV decreased to 99.64 % in 1.0 cm body shape increase, and in 10 MV and 15 MV dose decreased to 99.79 % and 99.97 % in 1.5 cm body increase, respectively. In 2.0 cm body type increase, the dose was decreased to 99.30 % and 99.52 %, respectively. Doses for rectum and bladder gradually increased with decreasing weight, and dose decreased with decreasing weight. 6 MV, and $V_{70Gy}$ at 10 MV increased from 11.50 % to 12.76 % when the external shape decreased by 2.0 cm. The bladder $V_{70Gy}$ also increased from 14.0 % to 15.2 %. It was also shown that the dose increased as the body weight decreased in the femoral head. Conclusion : In the treatment of VMAT, dose distribution can be changed according to the change of abdominal shape. SSD and CBCT were used to decrease the body shape by more than 1cm or more than 1.0 cm at 6 MV and the body shape by more than 1.5 cm or more than 1.5 cm at 10 MV or 15 MV. It is considered that a new treatment plan should be established through re-simulation.

  • PDF