• Title/Summary/Keyword: condensation method

Search Result 573, Processing Time 0.027 seconds

Construction and Evaluation of $O_3$ Condensation System for Oxide Thin Film (산화 박막 성장을 위한 $O_3$ 농축 시스템의 구축 및 평가)

  • Lim, Jung-Kwan;Ryu, Sun-Jong;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1192-1195
    • /
    • 2003
  • A highly condensed ozone gas be transferred to the superconductor thin film growth chamber because ozone is strong oxidizing gas. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure.

  • PDF

A Study on the Prediction Method of Condensation on the Curtain Wall of the High-rise Apartment Unit (초고층 아파트의 커튼월 결로 예측 방법에 관한 연구)

  • Im, Jeong-Hui
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.41
    • /
    • pp.88-101
    • /
    • 2007
  • Recently, the condensation of walls often occurring in domestic high-rise apartment buildings is an important problem. The main purpose of this study is to develop the prediction method for the surface condensation on curtain wall in high-rise apartment buildings. Therefore, in this study, we first analyzed exterior climate factors through the analysis of the Seoul climate data and predicted the change of indoor temperature by using Apache program to find the cause of the condensation state and to prevent condensation. Also, according to this result, exterior climate factors and interior factors, which caused the condensation, was examined. The thermal performance of the curtain wall and the range of potential condensation were analyzed to focus on high-rise apartment buildings through computer simulation programs. The results are as $follows;^1$) The frame edge of curtain wall has a higher U-value than in the center by $30%^2$) Because of stack effect, the rooms on the higher floor have a lower external ventilation rate resulting to a higher relative humidity3) Installing a ventilation system($20m^3$/h. person) makes it possible to have a higher external ventilation rate, resulting to a lower relative humidity.

  • PDF

An Experimental and Simulation Analysis of Condensation in the Walk-in Closet Attached to Apartment Bathroom (욕실과 인접한 아파트 드레스룸의 결로 원인 분석)

  • Choi, Young-Woo;Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • Purpose: Condensation in walk-in closets attached to apartment bathroom has been known as an emerging issue that may threat occupants' comfort and health. Despite a number of design guidelines and enforcements to prevent condensation, condensation issues may still occur depending on various cases and scenarios. We aim to identify what condensation scenarios may lead to walk-in closet condensation and/or worse the existing condensation issues. Method: First we choose an actual walk-in closet of an apartment that suffers from sporadic condensation and resulting mold and mildew. Then we observe its relative humidity and temperature after the bathroom is used, in which excessive vapor is thought to be transported to the walk-in closet. We analyze Temperature Difference Ratio - a domestic indicator of condensation occurrence, and dew point temperature to compare it with surface temperature using 2D heat transfer simulation upon various condensation scenarios. Result: TDR of the test walk-in closet turns out be OK despite mold and mildew actually occurring. Hot water pipe installed in the floor would greatly reduce condensation. If hot water pipe in the upper floor, however, is not used, or hot water pipe of the closet is turned off during swing seasons, it is expected that condensations may still occur.

A Study on Condensation Heat Transfer to Some Evaporated Metal Surface (각종증착금속면의 응축열전달에 관한 연구)

  • Jho Shi Gie;Lee Ki Woo;Park Young Jae;Cko Myong Jae
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.2
    • /
    • pp.188-195
    • /
    • 1986
  • Condensation heat transfer can be classified in dropwise condensation and filmwise condensation, and for the industrial purpose, the former is more useful than the latter because of the higher heat transfer rate. But it is difficult to maintain the dropwise condensation continuously since most of the metal surfaces become wetted after exposure to a condensing vapor over an extended period of time. To maintain dropwise condensation continuously , various surface coatings and promoters have been used recently, but these methods must be reconsidered about the durability of condensing surface. Therefore, in this study, evaporating method of various pure metals on the condensing surface has been performed to maintain dropwise condensation. The results have showed that the heat transfer rate of silver evaporating surface is higher than any other metal evaporating in dropwise area. Transition temperature and filmwise condensation curves are uniform regardless of kinds of evaporating metals.

  • PDF

Passive Prandtl-Meyer Expansion Flow with Homogeneous Condensation

  • Baek, Seung-Cheol;Kwon, Soon-Bum;Kim, Heuy-Dong
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.407-418
    • /
    • 2004
  • Prandtl-Meyer expansion flow with homogeneous condensation is investigated experimentally and by numerical computations. The steady and unsteady periodic behaviors of the diabatic shock wave due to the latent heat released by condensation are considered with a view of technical application to the condensing flow through steam turbine blade passages. A passive control method using a porous wall and cavity underneath is applied to control the diabatic shock wave. Two-dimensional, compressible Navier-Stokes with the nucleation rate equation are numerically solved using a third-order TVD (Total Variation Diminishing) finite difference scheme. The computational results reproduce the measured static pressure distributions in passive and no passive Prandtl-Meyer expansion flows with condensation. From both the experimental and computational results, it is found that the magnitude of steady diabatic shock wave can be considerably reduced by the present passive control method. For no passive control, it is found that the diabatic shock wave due to the heat released by condensation oscillates periodically with a frequency of 2.40㎑. This unsteady periodic motion of the diabatic shock wave can be completely suppressed using the present passive control method.

Optimization of Condensation Ratio for Fast Image Retrieval (영상 검색의 속도 향상을 위한 차원 축소율 최적화)

  • 이세한;이주호;조정원;최병욱
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1515-1518
    • /
    • 2003
  • This paper suggests the condensed two-stage retrieval method for fast image retrieval in the content-based image retrieval system, and proves the validity of the performance. The condensed two-stage retrieval method reduces the overall response time remarkably while it maintains relevance with the conventional exhaustive search method. It is explained by properties of the Cauchy-Schwartz inequality. In experimental result, it turns out that there is an optimal value of condensation ratio which minimizes the overall response time. We analyze the optimal condensation ratio by modeling a similarity computation time mathematically.

  • PDF

Dynamic Analysis of Vehicle-Bridge System by the Dynamic Condensation Method (Dynamic Condensation Method를 이용한 차량-교량계의 동적해석)

  • Han, Jae-Ik;Lee, Kyeong-Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.177-184
    • /
    • 1998
  • The equation of motion on the vehicle-bridge system is established as the simultaneous equations which are combined the equation of vehicle and bridge by the interaction elements. A vehicle element is modeled as lumped masses supported by springs and dashpots, and a bridge element with pavement roughness is modeled as beam elements. An interaction element is defined to consist of a bridge element and the suspension units of the vehicle resting on the element. By the dynamic condensation method, the degrees of the freedom are eliminated, and compared with all the degrees of freedom on the bridge, the efforts of calculation is decreased. Thus, although a very small computational error is occured, the present technique appears to be computationally more efficient. It is particularly suitable for the simulation of bridges with a series of vehicles moving on the deck.

  • PDF

Approximate Solution for Conjugate Heat Transfer of Laminar Film Condensation on a Flat Plate (평판의 층류 막응축에서 복합열전달에 대한 근사해)

  • Lee Euk-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.509-518
    • /
    • 2005
  • Liquid film thickness in laminar film condensation for flow over a flat plate generally is so thin that both fluid acceleration and thermal convection within the liquid film can be neglected. An integral solution method is proposed to solve the conjugate problems of laminar film condensation and heat conduction in a solid wall. It is found that approximate solutions of the governing equations involve four physical parameters to describe the conjugate heat transfer problem for laminar film condensation. It is shown that the effects of interfacial shear. mass transfer and local heat transfer are strongly dependent on the thermo-physical properties of the working fluids and the Jacob number.

Classification and Tracking of Hand Region Using Deformable Template and Condensation (Deformable Template과 Condensation을 이용한 손 영역 분류와 추적)

  • Jeong, Hyeon-Seok;Joo, Young-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1477-1481
    • /
    • 2010
  • In this paper, we propose the classification and tracking method of the hand region using deformable template and condensation. To do this, first, we extract the hand region by using the fuzzy color filter and HCbCr color model. Second, we extract the edge of hand by applying the Canny edge algorithm. Third, we find the first template by calculating the conditional probability between the extracted edge and the model edge. If the accurate template of the first object is decided, the condensation algorithm tries to track it. Finally, we demonstrate the effectiveness and feasibility of the proposed method through some experiments.

A Study on the Sensor Placement for Structural Damage Detection (구조물의 손상탐지를 위한 센서위치 연구)

  • Choi, Young-Jae;Lee, U-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.938-945
    • /
    • 2003
  • In the present study, the inverse perturbation method is applied to the structural damage detection in conjunction with a system condensation technique. The system condensation technique is adopted to r esolve the problem due to the incomplete measurement of the degrees-of-freedom (DOFs) in a natural mode. However, the numerical difficulty may arise in the system condensation when the DOFs to be measured are not properly selected. Thus, the issue of sensor placement for structural damage detection, in the framework of the condensation technique-based inverse perturbation method, is considered in this study. Also, a methodology to measure the number of sensors required to obtain reliable damage detection is proposed and then verified through some illustrative example problem.