• Title/Summary/Keyword: concrete building

Search Result 4,548, Processing Time 0.025 seconds

Evaluation of Pumping Characteristics of High Strength Concrete using Continuous Pumping System

  • Kwon, Dae-Hun;Lee, Han-Seung;Jeon, Jun-Young;Jeong, Woong-Taek;Jo, Ho-Kyoo;Kim, Hyung-Rae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.387-395
    • /
    • 2011
  • In the construction of tall-building, concrete pumping influences the success of the project. In order to establish pumping technology for high speed construction of tall building, study for quantitative evaluation of flow characteristics and pumpability should be conducted. So in this study, the characteristics including the inner pipe pressure, rheological properties of concrete and mortar through the continuous pumping test were evaluated. Then we analyzed the relations between rheological properties and pumpability. In the result of test, there are high correlations between the rheological characteristics which represented by yield stress and plastic viscosity and pressure loss with pipe length. Also, we estimated pressure loss according to conditions of concrete mix and pumping through the evaluation of inner pipe friction.

A Study on the CO2 Balance Evaluation of Building and Civil Engineering Structures (건축 및 토목 구조물의 CO2 수지 평가에 관한 연구)

  • Cho, Hyeong-Kyu;Song, Hun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.121-122
    • /
    • 2011
  • Globally about 40% of total carbon dioxide emissions occupies from the construction industry. Therefore, it is important to quantitatively calculate carbon dioxide emission of concrete prior to the reduction of carbon dioxide. ddd In addition, it is also important to quantitatively calculate carbon dioxide absorption of concrete because concrete absorbs in a measure of carbon dioxide. In this study, it carried out carbon dioxide balance evaluation of building and civil engineering structures through carbon dioxide balance evaluation method of concrete. Consequently absorption rate compared with carbon dioxide emission is about 2.5~5.18%.

  • PDF

A study on the quality improvement plan of recycled aggregate concrete for the use of building materials (건축자재 활용을 위한 순환골재 콘크리트의 품질개선 방안 연구)

  • Kim, Tae-Hyun;Hong, Sung-In;Choi, Yun-Jeong;An, Jae-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.162-163
    • /
    • 2022
  • Recycled aggregate has structural limitations in that it cannot be actively used for use as a structural building material due to quality deviations such as increase in cracks, decrease in constructability during in-situ casting, and decrease in strength. Although the government gives incentives to use recycled aggregate concrete for major structural parts of buildings to revitalize recycled aggregate concrete, there is a perception that the quality control of recycled aggregate producers that produce raw materials is insufficient. In this study, recycled aggregate, I checked the quality of the company that handles the quality. We are working on this.

  • PDF

Spatting Resistance of High Strength RC Column Covering Spray-on Materials of Fiber Composite Spray Mortar(FCSM) (섬유복합모르터의 뿜칠마감에 의한 고강도콘크리트 기둥부재의 폭렬방지)

  • Song Yong-Won;Han Dong-Yeob;Lee Gun-Cheol;Goh Kyoung-Taek;Kim Jin-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.5-8
    • /
    • 2006
  • High strength concrete has been increasingly used in high rue building and it is very obvious re consider fire resistance performance of that. Unlike the normal strength concrete, high strength concrete in sudden elevating temperature at fire is susceptible to spalling with severe explosion and surface split, due to high density of concrete. In order to endure the spalling, inner space temperature of concrete should be control less than certain point. Therefore this study investigated the influence of covering materials on high strength concrete finishing spray-on materials of fiber composite spray mortar(FCSM). Both polypropylene(PP) and polyvinyl alcohol(PVA) fiber were used in this test. Test showed that concrete, covering 18mm mortar containing PVA fiber and confining metal lath 2.3mm thickness, decreased 50% of main bar ambient temperature. compared with control concrete. In addition, concrete covering 18mm mortar without fiber caused falling of covering materials and then it was exposed in elevating temperature. As a result, spatting of the concrete occurred same as control concrete. However, concrete covering spray-on mortar containing PVA or PP fiber resisted spatting occurrence.

  • PDF

Evaluation on Spalling Properties of 80MPa High Strength Concrete with Fireproof Coating (내화피복재에 따른 80MPa 고강도 콘크리트의 폭렬 특성 평가)

  • Park, Gwi-Min;Kim, Gyu-Yong;Choe, Gyeonh-Cheol;Yoon, Min-Ho;Lee, Young-Wook;Hwang, Eui-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.126-127
    • /
    • 2015
  • Because of the high-rise and bigger building structure, high strength concrete's demand was increased. However, chemicophysical property of concrete is changed by high temperature. Therefore, this study evaluated on spalling properties of 80MPa high strength concrete with fireproof coating. The result, when complex fireproof coating spread on concrete, it has good fire safety that was thinner than single fireproof coating spread on concrete.

  • PDF

Effect of Silica Fume and Slag on Compressive Strength and Abrasion Resistance of HVFA Concrete

  • Rashad, Alaa M.;Seleem, Hosam El-Din H.;Shaheen, Amr F.
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.1
    • /
    • pp.69-81
    • /
    • 2014
  • In this study, portland cement (PC) has been partially replaced with a Class F fly ash (FA) at level of 70 % to produce high-volume FA (HVFA) concrete (F70). F70 was modified by replacing FA at levels of 10 and 20 % with silica fume (SF) and ground granulated blast-furnace slag (GGBS) and their equally combinations. All HVFA concrete types were compared to PC concrete. After curing for 7, 28, 90 and 180 days the specimens were tested in compression and abrasion. The various decomposition phases formed were identified using X-ray diffraction. The morphology of the formed hydrates was studied using scanning electron microscopy. The results indicated higher abrasion resistance of HVFA concrete blended with either SF or equally combinations of SF and GGBS, whilst lower abrasion resistance was noted in HVFA blended with GGBS.

An Experimental Study on the Fire Resistance Properties of High Strength Concrete using Fiber for Field Application (현장 적용을 위한 섬유혼입 고강도콘크리트의 내화특성에 관한 실험적 연구)

  • Kim, Yong-Ro;Song, Young-Chan;Jungi, Yang-Hee;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.187-191
    • /
    • 2008
  • It is necessary to develop a technology for effectively controling explosive spalling of high strength concrete caused increasing construction of high rise building and putting up the fireproof standard of high strength concrete by MLTM (Ministry of Land, Transport and Maritime Affairs). Accordingly, it was investigated basic properties such as slump, air content and compressive strength, and fire resistance properties of high strength concrete using polypropylene fiber for field application as a countermeasure for explosive spalling of concrete on fire in this study, As a test result, it was confirmed that PP fiber is available as fire resistance method of high strength concrete.

  • PDF

Study on the Exposed Concrete Construction Formwork According to Attachment Materials (거푸집 붙임재료에 따른 노출콘크리트 시공에 관한 연구)

  • Park, Se-Jun;Lee, Yun-Suk;Lee, Young-Do
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.223-224
    • /
    • 2016
  • Recent local advantages to improve the aesthetics of building materials connected with one of the trend of Exposed Concrete and Construction Method in various facilities and to diversify Showing a tendency to both application and development. This exposed concrete form of the features and materials is, the impact of large commercial viability and can consider I can apply to the surface of construction on a surface The diversification of the material was soon exposed directly linked to the varying aesthetics of concrete, and currently take advantage of the form of material is based on such important factor in our country Based on the concept of Exposed Concrete utilized by some construction site, design and be considered is very important elements of the put to practical use.

  • PDF

A fundamental Study on the Workability and Engineering Properties of Steel-Fiber Reinforced Silica Fume Concrete (강섬유보강 실리카.흄 콘크리트의 시공성 및 공학적 특성에 관한 기초적 연구)

  • 권영진;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.157-162
    • /
    • 1990
  • Recently, the multistory building construction of reinforced concrete has increased year by year, trended to be high rise in the view of effective land use planning, costing down of building construction and residential conditions. For this urgent need in construction industry, research and development of workability and engineering properties of high strength concrete has been closed up as one of the big world wide problems to be solved reasonably. It is aim of this study to provide the fundamental data the workability and engineering properties of steel-fiber reinforced high strength concrete containing silica-fume and fly-ash comparing with plain concrete for the practical use and research data accumulation in the side of development of new material in the building construction.

  • PDF

Measured and Predicted Column Shortening of a Tall Reinforced Concrete Building (고층 콘크리트 건물의 기둥축소량 계측연구)

  • 김원상;조한욱;오정근;염경수
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.161-170
    • /
    • 1999
  • The KLCC Petronas Tower 2, one of the world tallest twin reinforced concrete towers constructed in Kuala Lumpur, Malysia, was instrumented during construction for the measurement of vertical time-dependent deformation of columns and corewall. Field measurements were made by means of vibrating wire strain gauges at the corewall, tower and bustle perimeter columns at selected floor levels of the building. Parallel to this observation, laboratory tests were performed on concrete cylinders made in the field in order to obtain the variations of concrete compressive strengths, elastic moduli, strains of creep and shrinkage with time. Monitored vertical deformations are in a good agreement with the prediction based on actual construction sequence and concrete properties from laboratory tests, as well as the analytical results reflected in actual column compensation of the building.