• Title/Summary/Keyword: concentration measure

Search Result 1,486, Processing Time 0.029 seconds

A Retrieval of Vertically-Resolved Asian Dust Concentration from Quartz Channel Measurements of Raman Lidar (라만 라이다의 석영 채널을 이용한 고도별 황사 농도 산출)

  • Noh, Young-Min;Lee, Kwon-Ho;Lee, Han-Lim
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.326-336
    • /
    • 2011
  • The Light Detection and Ranging (Lidar) observation provides a specific knowledge of the temporal and vertical distribution and the optical properties of the aerosols. Unlike typical Mie scattering Lidars, which can measure backscattering and depolarization, the Raman Lidar can measure the quartz signal at the ultra violet (360 nm) and the visible (546 nm) wavelengths. In this work, we developed a method for estimating mineral quartz concentration immersed in Asian dust using Raman scattering of quartz (silicon dioxide, silica). During the Asian dust period of March 15, 16, and 21 in 2010, Raman lidar measurements detected the presence of quartz, and successfully showed the vertical profile of the dust concentrations. The satellite observations such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) confirmed spatial distribution of Asian dust. This approach will be useful for characterizing the quartz dominated in the atmospheric aerosols and the investigations of mineral dust. It will be especially applicable for distinguishing the dust and non-dust aerosols in studies on the mixing state of Asian aerosols. Additionally, the presented method combined with satellite observations is enable qualitative and quantitative monitoring for Asian dust.

DETERMINATION OF THE 129I IN PRIMARY COOLANT OF PWR

  • Choi, Ke Chon;Park, Yong Joon;Song, Kyuseok
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.61-66
    • /
    • 2013
  • Among the radioactive wastes generated from the nuclear power plant, a radioactive nuclide such as $^{129}I$ is classified as a difficult-to-measure (DTM) nuclide, owing to its low specific activity. Therefore, the establishment of an analytical procedure, including a chemical separation for $^{129}I$ as a representative DTM, becomes essential. In this report, the adsorption and recovery rate were measured by adding $^{125}I$ as a radio-isotopic tracer ($t_{1/2}$ = 60.14 d) to the simulation sample, in order to measure the activity concentration of $^{129}I$ in a pressurized-water reactor primary coolant. The optimum condition for the maximum recovery yield of iodine on the anion exchange resins (AG1 x2, 50-100 mesh, $Cl^-$ form) was found to be at pH 7. In this report, the effect of the boron content in a pressurized-water reactor primary coolant on the separation process of $^{129}I$ was examined, as was the effect of $^3H$ on the measurement of the activity of iodine. As a result, no influence of the boron content and of the simultaneous $^3H$ presence was found with activity concentrations of $^3H$ lower than 50 Bq/mL, and with a boron concentration of less than 2,000 ${\mu}g/mL$.

The Effects of Palmulgunja-tang(八物君子湯)Enzyme Activity on Cytochrome P450 Isozyme (팔물군자탕(八物君子湯) Cytochrome P450 효소(酵素) 활성에 미치는 영향)

  • Ryu, Jung-Man;Park, Seong-Sik
    • Journal of Sasang Constitutional Medicine
    • /
    • v.17 no.2
    • /
    • pp.64-73
    • /
    • 2005
  • 1. Objectives The purpose of this study was to investigate the effects of the enzyme activity of Palmulgunja-tang with administered orally solution on cytochrome P450 isozyme 2. Methods This study was carried on through following methods. We treated the rat with the {3-naphthoflavone (${\beta}NF$) of 80mg/kg for 3 days i.p injection. Firstable, microsomal protein was separated and total intracellular protein test was done. Then GOT and GPT were measured and assay of cytochrome P450 IAI/2 enzyme activity was performed according to the method of EROD and MROD. (Ethoxyresorufin-O-deethylase(EROD) activity was used to measure cytochrome P450 lAI activity and methoxyresorufin O-demethylase(MROD) activity was used to measure cytochrome P450 lA2 activity. ) 3. Results and Conclusions 1) PGT recovered the liver damage on ${\beta}NF$ inducible CYP IAI/2 by pre-post and high-low condition. 2) At concentration of post-treated 50mg!kg of PGT, the inhibiting of $\betaNF$ metabolites to liver of rat cytochrome P450 lAl was inhibited by 53.0% respectively. 3) PGT showed 36.0% inhibition of ${\beta}NF$-induced lA2 activity at the concentration post-treated 50mg/kg.

  • PDF

Electrical and Morphology Properties of Self-Assembled Dendrimer on Au (111) Substrate (Au (111)기판에 자기조립된 덴드리머 분자의 형태와 전기적 특성에 관한 연구)

  • Jung, Kyung-Han;Shin, Hoon-Kyu;Kim, Chung-Kyun;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.120-123
    • /
    • 2003
  • To investigate the characteristics of the single dendrimer molecule, we attempt to measure morphology and electrical properties of the self-assembled dendrimer on Au (111)substrate with SPM(scanning probe microscopy). The same self-assembly procedure was used for two different concentrations, $10{\mu}mol/ml$ and $100{\mu}mol/ml$. The case of lower concentration, we can measure the diameter and the height of the single molecule with the tapping mode AFM image. The imaged single molecules were dome shaped and the average diameter and height were 15.6 nm, 1.2 nm respectively. From these sizes, we can calculate the volume of the single molecule. The volume of the single molecule was estimated about $116nm^3$. However, that of higher concentration, it is difficult to obtain obvious image of the single molecule. To add to, I-V characteristics were investigated using STM, on which the phenomenon of negative differential resistance (NDR)was observed between 0.14 V and 0.24 V reproductively.

  • PDF

Determination of Frequency for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA SoC (FPGA SoC를 이용한 네모파 전압전류법의 주파수 변화에 따른 계측 분석)

  • Lee, Jaechoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.101-107
    • /
    • 2018
  • In the stripping scan square wave voltammetry (SV+SWV) polarography that is often used to analyze the concentration of heavy metals in water, we must measure the point where the faradic current that flows by the pure oxidation-reduction reaction at the electrode is greater than the capacitive current, the frequency cannot be too high. Therefore we wanted to find the frequency range that can be measured. In order to do this, we came up with a method to analyze the signal using FPGA Soc. With this method, the frequency of the square wave was increased from 10Hz to 400Hz by 10Hz, and the measuring time of the square wave was changed from 96.695% to 96.765% by 0.005% while 1600 experiments were conducted. As a result, the frequency of the square wave maintained a stable area of potential-current within 320Hz and it was possible to measure the potential-current signal when calculating the measuring time within the frequency range of 96.7155%.

Measurement of Black Carbon Concentration in Rural Area (교외지역 블랙카본 농도 측정)

  • Lee, Ki Woong;Han, Seung Cheol;Lee, Jeonghoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • We measured black carbon concentration in rural area to understand the characteristic of atmospheric aerosol by comparing the black carbon concentration and meteorological factors such as PM10 concentration, relative humidity, temperature and wind velocity. A MAAP (Multi Angle Absorption Photometer) which is one of filter based equipments was used to measure black carbon concentration. Black carbon concentration was measured to be high from April to May and low from June to September. Black carbon concentration was proportional to PM10 concentration. Black carbon concentration was correlated to relative humidity. Black carbon concentration was inversely proportional to wind velocity and temperature. Finally, we suggest that the volume fraction of black carbon in the atmosphere can be estimated from the size, number concentration and absorption coefficient measured using the MAAP.

Effect of Cutout Orientation on Stress Concentration of Perforated Plates with Various Cutouts and Bluntness

  • Woo, Jin-Ho;Na, Won-Bae
    • International Journal of Ocean System Engineering
    • /
    • v.1 no.2
    • /
    • pp.95-101
    • /
    • 2011
  • Perforated plates with cutouts (or holes) are widely used in structural members. These cutouts provide stress concentration in plates. Extensive studies have been carried out on stress concentration in perforated plates, which consider cutout shapes, boundary conditions, bluntness of cutouts, and more. This study presents stress concentration analyses of perforated plates with not only various cutouts and bluntness but also different cutout orientations. Especially, the effect of cutout orientation on stress concentration is emphasized since structural members have become more complicated recently. To obtain stress concentration patterns, a finite element program, ANSYS, is used. For the designated goal, three parameters are considered as follows: the shapes of polygonal cutouts (circle, triangle, and square), bluntness (a counter measure of radius ratio, r/R), and rotation of cutouts (${\theta}$). From the analyses, it is shown that, in general, as bluntness increases, the stress concentration increases, regardless of the shape and rotation. A more important finding is that the stress concentration increases as the cutouts become more oriented from the baseline, which is the positive horizontal axis (+x). This fact demonstrates that the orientation is also a relatively significant design factor to reduce stress concentration. In detail, in the case of the triangle cutout, orienting one side of the triangle cutout to be perpendicular to the applied tensile forces is preferable. Similarly, in the case of the square cutout, it is more advantageous to orient two sides of square cutout to be perpendicular to the applied tensile force. Therefore, at the design stage, determining the direction of a major tensile force is required. Then, by aligning those polygon cutouts properly, we can reduce stress concentration.

A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes (다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구)

  • Ahn, Gwang-Hoon;Kwon, Jong-Won;Kim, Gyu-Sik;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

Proposal of Bond Strength Evaluation Method for Overlay Concrete at Field (유한요소해석을 이용한 현장 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • Lee, Bong-Hak;Hong, chang-Woo;Lee, Joo-Hyung;Kim, Seong-Hwan
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.295-300
    • /
    • 2001
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction defends upon band strength between old and the new concrete. Current adhesion strength measurement method is inaccurate method that ignore effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5 cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF

Studies on the Preparation of Polyurethane Diagnostic Membranes for Blood Glucose Measurements (5) : Effects of Temperature and Humidity on the Measurements of Glucose Concentration (혈당측정을 위한 폴리우레탄 진단막의 제조에 관한 연구(5) : 온도와 습도가 글루코우즈의 농도 측정에 미치는 영향)

  • Kwon, Suk-Ky;Park, In-Hee;Yoon, Do-Young
    • Membrane Journal
    • /
    • v.17 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • Polyurethane diagnostic membranes were prepared to measure blood glucose level of diabetics. Final absorbances at 680 nm through activated polyurethane membranes were measured at various concentration of glucose in plasma or blood. The effects of storage temperatures on the measurements of glucose concentration were studied after storage of 3 days, 1 week, 3 weeks, and 5 weeks at various temperatures. The stabilities of polyurethane diagnostic membranes were examined at RH 80%.