• Title/Summary/Keyword: computed tomography image

Search Result 966, Processing Time 0.02 seconds

Comparative Study for the Measurement of Fermoral Anteversion by Manual Method and Image Viewer (대퇴골 전염각 측정을 위한 수 작업 방법과 Image Viewer 방법과의 비교 연구)

  • Gwon, Dae-Cheol;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • The measurement of the fermoral anteversion is an important factor in the practice of orthopedic surgery. The anteversion is measured by means of the axis of head and neck of the femur. In this study. widely used computed tomography method of measuring anteversion was tested on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In January and February 2001, 30 patients 3 to 6 years of age were randomly selected from Seoul National University Hospital. the purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing image viewer program. This new method was more accurate and convenient than the conventional manual method. No significant difference was observed between the manual method and the image viewer measurement of femoral anteversion. In conclusion, image viewer program was statistically more reliable in determining the angle of the fermoral anteversion.

  • PDF

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Analysis of the priority of anatomic structures according to the diagnostic task in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.245-249
    • /
    • 2016
  • Purpose: This study was designed to evaluate differences in the required visibility of anatomic structures according to the diagnostic tasks of implant planning and periapical diagnosis. Materials and Methods: Images of a real skull phantom were acquired under 24 combinations of different exposure conditions in a cone-beam computed tomography scanner (60, 70, 80, 90, 100, and 110 kV and 4, 6, 8, and 10 mA). Five radiologists evaluated the visibility of anatomic structures and the image quality for diagnostic tasks using a 6-point scale. results: The visibility of the periodontal ligament space showed the closest association with the ability to use an image for periapical diagnosis in both jaws. The visibility of the sinus floor and canal wall showed the closest association with the ability to use an image for implant planning. Variations in tube voltage were associated with significant differences in image quality for all diagnostic tasks. However, tube current did not show significant associations with the ability to use an image for implant planning. conclusion: The required visibility of anatomic structures varied depending on the diagnostic task. Tube voltage was a more important exposure parameter for image quality than tube current. Different settings should be used for optimization and image quality evaluation depending on the diagnostic task.

On the development of S/W tools for industrial 3D X-ray computed tomography employing general software (범용 소프트웨어를 사용한 산업용 3차원 X-ray Computed Tomography의 툴 개발)

  • Choi, Hyeong-Seok;Yang, Yoon-Gi
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.768-776
    • /
    • 2019
  • With the deployment of 4-th generation industrial revolution, the computer based manufacturing technologies employing advanced IT technology are much more popular than any other past years. In this research, some novel S/W technologies related to the industrial X-ray CT (computed tomography) for the inspection of the industrial parts are introduced. First, newly constructed industrial X-ray CT is presented in this paper, where some basic principles and functions of the CT are described. Then some research platforms are developed to generate more advanced functionalities of the industrial CT. Especially, the data transform from CT to general S/W such as Matlab is conducted. And based on this techniques, some supplementary S/W platform such as GUI (graphical user interface) of the CT S/W and some 3D voxel based image processing technologies can be developed in this paper. The industrial CT is one of the rare research items and it's values can be much more enhanced when it is used with advanced IT technologies.

The using of megavoltage computed tomography in image-guided brachytherapy for cervical cancer: a case report

  • Tharavichitkul, Ekkasit;Janla-or, Suwapim;Wanwilairat, Somsak;Chakrabandhu, Somvilai;Klunklin, Pitchayaponne;Onchan, Wimrak;Supawongwattana, Bongkot;Galalae, Razvan M.;Chitapanarux, Imjai
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.155-159
    • /
    • 2015
  • We present a case of cervical cancer treated by concurrent chemoradiation. In radiation therapy part, the combination of the whole pelvic helical tomotherapy plus image-guided brachytherapy with megavoltage computed tomography of helical tomotherapy was performed. We propose this therapeutic approach could be considered in a curative setting in some problematic situation as our institution.

Generation of contrast enhanced computed tomography image using deep learning network

  • Woo, Sang-Keun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 2019
  • In this paper, we propose a application of conditional generative adversarial network (cGAN) for generation of contrast enhanced computed tomography (CT) image. Two types of CT data which were the enhanced and non-enhanced were used and applied by the histogram equalization for adjusting image intensities. In order to validate the generation of contrast enhanced CT data, the structural similarity index measurement (SSIM) was performed. Prepared generated contrast CT data were analyzed the statistical analysis using paired sample t-test. In order to apply the optimized algorithm for the lymph node cancer, they were calculated by short to long axis ratio (S/L) method. In the case of the model trained with CT data and their histogram equalized SSIM were $0.905{\pm}0.048$ and $0.908{\pm}0.047$. The tumor S/L of generated contrast enhanced CT data were validated similar to the ground truth when they were compared to scanned contrast enhanced CT data. It is expected that advantages of Generated contrast enhanced CT data based on deep learning are a cost-effective and less radiation exposure as well as further anatomical information with non-enhanced CT data.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.

Application of Computer-Aided Diagnosis for the Differential Diagnosis of Fatty Liver in Computed Tomography Image (전산화단층촬영 영상에서 지방간의 감별진단을 위한 컴퓨터보조진단의 응용)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we are using a computer tomography image of the abdomen, as an experimental linear research for the image of the fatty liver patients texture features analysis and computer-aided diagnosis system of implementation using the ROC curve analysis, from the computer tomography image. We tried to provide an objective and reliable diagnostic information of fatty liver to the doctor. Experiments are usually a fatty liver, via the wavelet transform of the abdominal computed tomography images are configured with the experimental image section, shows the results of statistical analysis on six parameters indicating a feature value of the texture. As a result, the entropy, average luminance, strain rate is shown a relatively high recognition rate of 90% or more, the control also, flatness, uniformity showed relatively low recognition rate of about 70%. ROC curve analysis of six parameters are all shown to 0.900 (p = 0.0001) or more, showed meaningful results in the recognition of the disease. Also, to determine the cut-off value for the prediction of disease six parameters. These results are applicable from future abdominal computed tomography images as a preliminary diagnostic article of diseases automatic detection and eventual diagnosis.

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Algorithm to Shorten Imaging Time in Fluorescent X-ray Computed Tomogrpahy (형광 X선 CT에서 촬상 시간의 단축화 알고리즘)

  • 정남채
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.4
    • /
    • pp.46-52
    • /
    • 2001
  • In this paper it was examined both imaging system and processing algorithm for imaging's high speedization of fluorescent X-ray computed tomography using synchrotron radiation, The electronic system was used for dead time by about 6% but shortening of measure time was achieved by 2 seconds per 1 point. Also efficiency of reconstruction algorithm was proved, and memory and calculation amount was decreased by about 1/100 The fixed quantity was confirmed by physical phantom, and iodine distribution was presumed from image of thyroid gland in vitro These result shows realization possibility of fluorescent X-ray computed tomography measure in vivo.

  • PDF