• 제목/요약/키워드: computed tomography image

검색결과 976건 처리시간 0.024초

Four-Dimensional Computed Tomography for Gated Radiotherapy: Retrospective Image Sorting and Evaluation

  • Lim, Sang-Wook;Park, Sung-Ho;Back, Geum-Mun;Ahn, Seung-Do;Shin, Seong-Soo;Lee, Sang-Wook;Kim, Jong-Hoon;Choi, Eun-Kyuong;Kwon, Soo-Il
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2005년도 제30회 춘계학술대회
    • /
    • pp.71-74
    • /
    • 2005
  • To introduce the four-dimensional computed tomography (4DCT, Light Speed RT, General Electric, USA) scanner newly installed in our department and evaluate its feasibility for gated radiotherapy. Respiratory signal measured by real-time position management (RPM$^{\circledR}$, Varian Medical, USA) was recorded in synchronization with the 4DCT scanner. 4DCT data were acquired in axial cine mode and sorted retrospective image based on respiratory phase. PTVs delineated from helical CT and 4DCT images were compared. The PTV delineated from conventional helical CT images was 2 cc larger than that from 4DCT images. Dose in PTV of the plan from retrospective CT was 99.3% (minimum=72.0%, maximum=106.5%) and that of helical CT plan was 95.2% (minimum=24.1%, maximum=106.4%) of prescribed dose. Comparing with DVHs of both plan, the coverage for 4CDT plan was 3.7% improved. It is expected that 4DCT could improve tumor control and reduce radiation toxicity for liver cancer.

  • PDF

Fast and Accurate Rigid Registration of 3D CT Images by Combining Feature and Intensity

  • June, Naw Chit Too;Cui, Xuenan;Li, Shengzhe;Kim, Hak-Il;Kwack, Kyu-Sung
    • Journal of Computing Science and Engineering
    • /
    • 제6권1호
    • /
    • pp.1-11
    • /
    • 2012
  • Computed tomography (CT) images are widely used for the analysis of the temporal evaluation or monitoring of the progression of a disease. The follow-up examinations of CT scan images of the same patient require a 3D registration technique. In this paper, an automatic and robust registration is proposed for the rigid registration of 3D CT images. The proposed method involves two steps. Firstly, the two CT volumes are aligned based on their principal axes, and then, the alignment from the previous step is refined by the optimization of the similarity score of the image's voxel. Normalized cross correlation (NCC) is used as a similarity metric and a downhill simplex method is employed to find out the optimal score. The performance of the algorithm is evaluated on phantom images and knee synthetic CT images. By the extraction of the initial transformation parameters with principal axis of the binary volumes, the searching space to find out the parameters is reduced in the optimization step. Thus, the overall registration time is algorithmically decreased without the deterioration of the accuracy. The preliminary experimental results of the study demonstrate that the proposed method can be applied to rigid registration problems of real patient images.

CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과 (Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography)

  • 정미영;권대철;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.307-312
    • /
    • 2009
  • CT 검사에서 수정체 차폐용 비스무트(bismuth)를 사용하여 수정체 선량의 감소효과를 유리선량계로 측정하여 비스무트 차폐효과 및 영상을 평가하였다. 안구 및 두부 CT 검사에서 차폐용 비스무트를 사용하여 수정체 선량의 감소와 차폐 효과를 평가하기 위해 인체모형 팬텀으로 유리선량계를 이용하여 수정체 선량을 평가하였다. 유리선량계를 이용하여 비스무트를 사용하기 전의 평균 선량은 21.54 mGy이었고, 사용 후의 선량은 10.46 mGy로 51.3%의 선량 감소효과가 있다. 차폐용 비스무트를 사용한 안구 64 MDCT 촬영에서 선량감소 효과가 있어 수정체를 포함한 안구 CT 스캔에서는 비스무트를 사용하여 검사하도록 권고한다.

  • PDF

반복법을 사용한 단층영상 재구성을 위한 투사기 및 역투사기의 고속 구현 (Fast Implementations of Projector-Backprojector Pairs for Iterative Tomographic Reconstruction)

  • 김수미;이수진;김용호
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권5호
    • /
    • pp.473-480
    • /
    • 2003
  • 반복법을 사용한 영상재구성은 기존의 여과역투사 방법에 비해 윌등한 장점을 가지고 있으므로 방출 전산화단층촬영에 있어 매우 중요한 역할을 해왔다. 그러나, 반복법을 사용한 영상재구성법은 데이터의 투사 및 역투사 계산의 반복으로 이루어져 있으므로 한 영상을 재구성하는데 필요한 계산량은 알고리즘의 구현을 위해 사용된 투사기 및 역투사기의 성능에 크게 좌우된다. 본 연구에서는 투사기 및 역투사기를 구현하기 위한 대표적 방법들의 성능을 정량적으로 비교한다. 각 구현방법에 있어서 투사-역투사 계산에 필요한 연산량을 줄이기 위해 이전에 계산된 결과들을 재사용함으로써 불필요하게 반복되는 연산들을 최소화하도록 하는 방법에 고찰한다. 실험결과에 의하면 선추적법은 연산속도 면에서 다른 방법에 비해 우수할 뿐 아니라, 정확성이 높은 개선된 영상을 제공하는 것으로 나타났다.

CT 이미지를 활용한 경량 골재의 방향에 따른 공극 분포 및 강성도의 이방성 분석 (Analysis on Anisotropy of Void Distribution and Stiffness of Lightweight Aggregate using CT Images)

  • 정상엽;한동석;윤태섭;염광수;전현규;강동훈
    • 한국전산구조공학회논문집
    • /
    • 제25권3호
    • /
    • pp.227-235
    • /
    • 2012
  • 대표적인 다상 재료인 콘크리트는 구성 성분의 공간적 분포에 의해 재료 특성이 큰 영향을 받는다. 특히 공극(void)은 콘크리트의 특성에 큰 영향을 주는 요인으로서, 콘크리트 내부에 분포하는 공극의 공간적 분포를 파악하는 것은 재료의 특성을 이해하는데 매우 중요하다. 본 연구에서는 콘크리트 내부에 존재하는 경량 골재의 공극 분포 분석을 위해서, CT(computed tomography)로부터 얻은 단면 이미지를 활용하여 생성된 3차원 경량 골재 이미지를 활용하여 공극 분포를 시각화(visualization)하였다. 방향에 따른 3차원 경량 골재 내부의 공극 분포 상태를 정성적으로 묘사하기 위해서 확률 분포 함수인 두점 상관함수(two-point correlation function)를 사용하여 공극의 공간적 분포 경향을 구(sphere)에 표현하였다. 또한 방향에 대한 골재의 강성도(stiffness)를 계산하여 각 방향에 따른 골재의 역학적 물성치 분포 변화를 확인하였다. 각 방향으로의 확률 분포 함수로 표현된 공극 분포와 강성도 분석함으로서 CT 이미지를 통한 공극 분포 특성 분석 및 경량 골재의 역학적 특성을 효과적으로 예측할 수 있음을 확인하였다.

Added Value of Diffusion Weighted Imaging for Detecting Pancreatic Abnormality in Patients with Clinically Suspected Acute Pancreatitis

  • Nam, In Chul;Kim, Seung Ho;Kim, Seon-Jeong;Lim, Yun-jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.241-249
    • /
    • 2016
  • Purpose: To evaluate the added value of diffusion weighted imaging (DWI) to computed tomography (CT) for detecting pancreatic abnormality in patients with clinically suspected acute pancreatitis (AP). Materials and Methods: 203 patients who underwent abdomen CT and subsequent DWI to do a workup for epigastric pain were analyzed. Two blinded radiologists independently performed an interval reading based on CT image sets first, then based on combined CT and DWI image sets. The diagnostic criterion on DWI was the increased signal intensity in the pancreas to that of the spleen. For quantitative analysis, the third radiologist measured ADC value of the pancreas in each patient. Results: For AP (n = 43), the sensitivity for detecting pancreatic abnormality increased, from 42% to 70% for reader 1 (P < 0.05) and from 44% to 72% for reader 2 (P < 0.05). For borderline pancreatitis (n = 42), the sensitivity also increased, from 10% to 26% for reader 1 (P < 0.05) and from 7% to 29% for reader 2 (P < 0.05). The mean ADC values (unit, ${\times}10^{-3}mm^2/s$) were significantly different among the three groups (for AP, $1.09{\pm}0.16$; for borderline pancreatitis, $1.28{\pm}0.2$; for control, $1.46{\pm}0.15$, P < 0.05). Conclusion: Sensitivity for detecting pancreatic abnormality increased significantly after adding DWI to CT in patients with clinically suspected AP.

Cone-Beam CT를 이용한 악교정 수술용 스텐트 제작과 임상 적용 (SURGICAL STENT FABRICATION AND CLINICAL APPLICATION FOR ORTHOGNATHIC SURGERY USING Cone-Beam CT)

  • 김용일;김종렬;김성식;손우성;박수병
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.158-166
    • /
    • 2009
  • The application of CT with basis on 3 dimensional-reconstruction is getting more widely practiced. With the data obtained from cone-beam computed tomography(CBCT), not only the diagnosis of the patient with skeletal abnormality but also the virtual simulation of the orthognathic surgery were performed and its application would be popular in orthodontic field. We reported a case, a 19-year old man who was diagnosed mandibular prognathism and required orthognatic surgery. In this case, the virtual orthognathic surgery was simulated and surgical wafer was fabricated by using CBCT data. That wafer was applied the actual orthognathic surgery. After preoperative orthodontic treatment, we prepared surgery as follows. : (l)Acquisition of 3D image data, (2)Reconstruction of 3-dimensional virtual model, (3)Virtual model surgery, (4)Extraction of stere-olithographic image, (5)Check-up for occlusal interference, (6)Fabrication of surgical stent by stereolithography. Bilateral sagittal split ramus osteotomy was operated and used stereolithographic surgical stent. 1 month later, we superimposed CBCT datas of virtual surgery and that of actual surgery, and then compared the result. CT data's application for othognathic surgery yielded satisfactory outcomes.

Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

  • Rabelo, Katharina Alves;Cavalcanti, Yuri Wanderley;de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Campos, Paulo Sergio Flores;de Andrade Freitas Oliveira, Luciana Soares;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.189-197
    • /
    • 2017
  • Purpose: To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Materials and Methods: Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. Results: There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos(P>.05). Conclusion: Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

두부 전산화단층촬영에서 노출 파라미터의 최적화 (Optimization of Exposure Parameters in Brain Computed Tomography)

  • 고성진;강세식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.355-362
    • /
    • 2010
  • 본 연구는 영상의 질을 저해하지 않는 범위 내에서 환자의 흡수선량을 최소화 할 수 있는 두부 전산화 단층촬영의 노출매개변수 값의 범위를 알아보고 선량감소가 필요한 환자에 대해서 적용 가능한 최적의 노출조건을 찾고자 하였다. 이를 위해 두부촬영 시 사용되는 기존의 전산화단층촬영 변수로부터 얻어진 영상의 선량과 잡음성분을 측정하였다. 또한 두부용 팬텀을 사용하여 관전압과 회전시간을 변화시켜서 영상을 얻었으며, 선량과 잡음(Noise), 최대량 신호대 잡음비(PSNR) 측정을 통해 실험 영상을 평가하였다. 실험결과는 첫째, 관전압과 회전시간을 변화시켜 선량을 측정한 결과 기존 두부촬영조건에서 얻어지는 선량의 재현성 실험에서 선량 측정값의 유효성이 입증되었다. 둘째, 저 선량과 고화질의 노출 조건을 찾기 위한 방법으로 선량과 잡음값의 관계는 의미가 없었으며, 선량과 PSNR값의 관계는 의미가 있었다. 이를 바탕으로 제조사에서 제시하는 촬영조건으로부터 선량의 감소가 필요한 경우 본 연구에서 제시한 새로운 노출조건을 사용한다면 환자의 흡수선량은 감소시키면서 기존에 제시된 노출조건으로부터 얻어진 영상과 유사한 화질의 영상을 얻을 수 있을 것이다.

안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구 (Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture)

  • 정성호;신승한;박승하;구상환
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.44-51
    • /
    • 2007
  • Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically. Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.