• Title/Summary/Keyword: collector efficiency

Search Result 326, Processing Time 0.021 seconds

Deinking efficiency of ONP with enzyme blended deinking agent (복합탈묵제의 ONP 탈묵 적성)

  • Yun, Kyong-Dong;Park, Heon-Sin;Eom, Tae-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.04a
    • /
    • pp.167-173
    • /
    • 2006
  • Deinking is a series of unit operations designed to detach ink from cellulose fibers and separate the dispersed ink from the pulp slurry. Deinking chemicals are process aids that enable expensive mill equipment used in these unit operations to operate more efficiently - often much more efficiently. We propose the blended deinking agent with cellulolutic enzymes and synthetic collector in deinking pulp of conventional alkaline method. The deinking efficiency of old news print in alkaline pH was enhanced with enzyme treatments. The brightness of deinked pulp was increased with less residual ink particles and yield of enzymatic deinked pulp was improved compared to the deinked pulp of conventional alkaline method. Enzymes in biomass were use to Chemical Deinking for reduce environment pollution through surfactant and improve surfactants. examining into compatibility Enzymes and surfactants, these new materials are studied efficiency of deinking efficiency.

  • PDF

Evaluation on Performance of an Electrostatic Diesel PM Trap Device and Its Application to Diesel Engine After-treatment (정전 방식 디젤 PM 포집 장치 성능 및 엔진 적용성 평가)

  • Kim, Hak-Joon;Han, Bang-Woo;Kim, Yong-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.176-183
    • /
    • 2008
  • Performance of electrostatic diesel PM filtration systems (E-DPS) with different types has been tested using the carbon particles generated by spark discharge in laboratory. Among the five electrostatic precipitators, the multiple wires cylindrical E-DPS with the highest collection efficiency and relatively lower differential pressure at the flow rate of $1\;m^3$/min, as an applicable device to diesel engine as an after treatment system, has been combined with another collection cylinder to improve the collection efficiency of diesel particulate matters generated from diesel engines. The multiple wires cylindrical E-DPS combined with the cylindrical collector showed the collection efficiency of more than 60% at the engine speed of 2,000 rpm with the engine loads of 25 and 50%.

A Detailed Examination of Various Porous Media Flow Models for Collection Efficiency and Pressure Drop of Diesel Particulate Filter (DPF의 PM 포집효율 예측을 위한 다양한 다공성 매질 유동장 모델 해석)

  • Jung, Seung-Chai;Yoon, Woong-Sup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.78-88
    • /
    • 2007
  • In the present study a detailed examination of various porous media models for predicting filtration efficiency and pressure drop of diesel particulate filter (DPF), such as sphere-in-cell and constricted tube models, are attempted. In order for demonstrating their validities of correct estimation on permeability, geometry of property configurations common in commercial cordierite DPFs are correlated to the porous media flow models, and validations of predicted filtration efficiencies due to the use of different unit collectors are made with experiments. The result shows that the porosity, pore size and permeability of cordierite DPF can be successfully correlated by Kuwabara flow field with correction factor of 0.6. The unit collector efficiency predicted by sphere-in-cell model agrees very well with measurements in accumulation mode, whereas that by constricted tube model with significant prediction error.

Performance improvement of wave plate mist eliminator through geometry modification (Wave plate 습분제거기의 형상 변경을 통한 성능 개선)

  • Jung-Hun, Noh;Min-Cheol, Cho;Seung-Jong, Lee
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.97-107
    • /
    • 2022
  • The geometry of popular wave plate type mist eliminator for the wet flue gas desulfurization process was improved, fabricated, and experimentally evaluated. A Mist eliminator is a type of inertial particle collector which collection efficiency is proportional to the velocity of the gas phase. However, as the amount of re-entrainment is also proportional to the gas phase velocity, there is a limitation for the gas phase flow rate. Re-entrainment is one of the most important issues in a mist eliminator and is likely to occur as the input of the liquid phase and flow rate of the gas phase increase. In order to resolve this problem, the projection angle of the improved mist eliminator is set to 30° from the conventional one while maintaining the cross-section. With low flow rate conditions, the modified mist eliminator showed a similar pressure drop and overall collection efficiency. However, with conditions in which re-entrainment is obviously occurring, the modified mist eliminator showed better performance in draining droplets than the conventional one. As a result, the modified mist eliminator showed higher overall collection efficiency.

A Study on the Design and Analysis of District Solar Heating and Cooling System with Preheating of Returning District Heating Water (지역난방수 환수 승온방식의 태양열 지역냉난방 시스템 분석)

  • Baek Nam-Choon;Shin U-Cheul;Lee Jin-Kook;Yoon Eung-Sang;Yoon Suk-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.433-437
    • /
    • 2005
  • This study was carried out the design and analysis of solar thermal system with preheating of returning district heating water for the Chung-ju district heating and cooling system. Two different types of solar collectors are used for this system. TRNSYS simulation program was used for the analysis. As a results, the solar system efficiency is $35.8\%$ for the plate type and $45.1\%$ for the evacuated type solar collector in the case of $50^{\circ}C$ for the returning district heating water temperature. The returning district heating water temperature is on of the very important factors that is influence on the system efficiency. So the effect of the returning district heating water temperature on the system efficiency is analyzed in this study.

  • PDF

The Simultaneous absorption of SOX-NOX using aqueous ammonia solution (암모니아수용액을 이용한 SOX-NOX 동시 흡수에 관한 연구)

  • Kim, Jae-Gang;Lee, Ju-Yeol;Park, Byung-Hyun;Choi, Jin-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.372-376
    • /
    • 2015
  • The experiment was performed using the cleaning precipitator To investigate the absorption efficiency of the $SO_X/NO_X$ of the aqueous ammonia solution. Concentration of the cleaning liquid is 0.1, 0.5, and 1.0% with increasing absorption efficiency has improved. However, the reaction shown only a difference in time. Absorption efficiency has improved in accordance with the gas residence time. When the direction of the same gas and the cleaning liquid is determined that there is the effect of increasing the residence time. The relative impact of $SO_X$ and $NO_X$ is this likely to react slower than $SO_X/NO_X$. The yield is determined to require adjustment of the cleaning dust collector according to the concentration of the next gas.

Comparison of Tangential and Axial Flow Cyclones for Small Dust Collectors (소형 집진기용 접선식 및 축류식 사이클론 성능비교)

  • Lee, Sungwon;Lee, Chungmin;Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2018
  • The tangential and axial cyclones were fabricated using a 3D printer and the total collecting efficiency, cut-diameter, and pressure drop characteristics of the two types of cyclones with the same inlet area were investigated experimentally. The results show that the total collecting efficiency tends to increase as the inlet velocity increases. However, at a 20m/s condition of the tangential cyclone, the collected particles were re-entrained to the ascending vortex flow, resulting in a decrease of the total collecting efficiency. In the axial cyclone, the cross-sectional area is designed to increase at the inlet and the velocity is reduced, so that the re-entrainment effect does not appear in this study. The pressure loss of the tangential cyclone was larger than that of the axial cyclone. The cut-diameter tends to decrease with increasing the inlet velocity in two types of cyclones, except for the 20m/s condition of the tangential cyclone.

An Experimental Study on the Removal Characteristics of Indoor Air Pollutants using an Air Cleaning System (실내 공기정화 시스템에 의한 실내 오염입자의 제거특성에 관한 실험적 연구)

  • 김성찬;이창건;안영철;이재근;강태욱;이감규;구정환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.733-737
    • /
    • 2003
  • The purpose of this study is to analyze the particle removal characteristics of a commercial air cleaner based on the electrostatic precipitator. The air cleaner consists of a positive corona precharger to precharge particles and a collector to remove the charged particles. The test for particle removal efficiency is conducted with tobacco smoke particles of 1.27${\mu}{\textrm}{m}$ in mass median diameter. The result of one-pass filtration test shows that the filtration efficiency is more than 90% for the particles larger than 2.5 Um, while the efficiency for the particles of 0.5~1.0${\mu}{\textrm}{m}$ in case of 4.18 CMM is 70%. For the test room of 5,800${\times}$3,400${\times}$2,600㎣, the concentration of tobacco smoke particles decreases up to 30% of initial values within 30 minutes due to natural reduction and up to 90% of initial values within 30 minutes with the air cleaner operation.

Performance Ratings According to Characteristics of Thermosyphon Solar Hot Water System (자연대류형 태양열온수기의 특성별 성능평가에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Yoo, C.G.;Yoon, H.G.;Kang, M.C.;Lee, D.G.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.9-17
    • /
    • 2000
  • To obtain thermal performance data, an experiment was performed with the two selected thermosyphon systems. The system parameters obtained by experimental data were used to perform TRNSYS simulation and verified TRNSYS model of thermosyphon solar hot water system. The thermosyphon solar hot water system was TYPE 145 which is modified from non-linear model. This model can describe heat exchange type and non-linear efficiency equation. It is possible to analyze the annual energy rate with efficiency equation and system specification. In this paper, we could compare the annual performance of the coil heat exchanger with that of the tank-in-tank heat exchanger. Under the same efficiency and parameter, heat exchange, drain, initial tank temperature, ratio of tank volume over collector area(V/Ac), regional annual performance rating were performed.

  • PDF

An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House (단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가)

  • Baek, Namchoon;Han, Seunghyun;Lee, Wang Je;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.