• Title/Summary/Keyword: co-housing

Search Result 387, Processing Time 0.027 seconds

A Study on Planning Element of Symbiotic Housing (환경공생주택(環境共生住宅)의 계획요소(計劃要素) 고찰(考察))

  • Kim, Young-Seok;Choi, Ki-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.165-172
    • /
    • 2003
  • Quantitative planning element and qualitative planning instruction which are required for planning and evaluating environment-friendly building are accessed in previous studies. In this study, the concept of symbiotic housing is introduced for upgrading existing planning elements, so as to study the planning elements collectively. This study can be summarized as below: (1) Planning elements for saving energy and using resources effectively are added in order to preserve the earth environment. (2) In order to harmonize with neighboring environment more, sunshine duration of neighboring buildings is considered; streets and village view are harmonized; space in-between is prepared. (3) For healthy and amenity residential environment, following items are added, improved pleasantness of inside and outside space; improved amenity and health of housing; and, co-dwelling with large scope. Besides, the necessity of residents' agreement is proposed to induce residents' participation, which has not been mentioned before.

  • PDF

Prediction of Noise & Vibration Effect of Agricultural Tractor Transmission at Design Stage

  • Kim, Jung-Hun;Kang, Young-Sun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.354-358
    • /
    • 1996
  • At design stage of the TRXI agricultural tractor transmission (New product of TongYang Moolsan Co., Ltd), the noise and vibration of the transmission were analyzed theoretically for the optimal design of the transmission . For this analysis, the finite element model was developed using a commercial computer software, ANSYS. The noise and vibration of the TRXI transmission housing were predicted by the modal analysis. Natural frequency of the TRXI transmission housing was ranged from 12.53Hz(1st mode ) to 30.05Hz(5th mode). The fifth mode took place at the bearing metal in the area of rear transmission housing and was very close to the gear mesh frequency (30.5Hz) of low rang gear at the low creep shifting . Based on the results , the bearing metal of the range shift housing was reenforced with the rib at design stage.

  • PDF

Analysis of mechanical characteristic of valve housing for automobile using 2-cavity die casting (2CAVITY 다이캐스팅을 이용한 자동차 VALVE HOUSING의 기계적 특성 해석)

  • Lee, Jong-Hyung;Yoon, Jong-Cheul;Yoo, Duck-Sang;Lee, Chang-Heon;Ha, Hong-Bae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.105-110
    • /
    • 2006
  • Valve-housing parts in car steering system is a part of steering system and then take charge of the main functions for car steering system to reduce driver's handling-force. Recently it is still not developed reliable casting for many cars, so it produce as a Gravity casting which is more than triple for producing cost in Korea. In this research, we had conducted that 350t aluminum die casting is superior to mechanical property from established over 500t or not for Valve-housing, a parts of steering system which were produced as a cast-iron product and the most suitable conditions to extruding as die casting.

  • PDF

A Study on the Application of Macro Model in the Housing Market with Integrated Information Platform (주택시장의 통합정보 플랫폼과 연계한 거시 모형 적용성 방안 연구)

  • Jung, Hoi-Min;Lee, Sang-Hun;Moon, Sung-Min
    • Annual Conference of KIPS
    • /
    • 2019.10a
    • /
    • pp.17-18
    • /
    • 2019
  • 오픈플랫폼 기반 주택시장 분석 플랫폼은 Linux(CentOS) 서버를 운영체제로 주택 분야 빅데이터 수집/가공/분석/예측을 위하여 Hadoop 기반으로 구축한 플랫폼이다. 오픈소스 플랫폼을 기반으로 다양한 대규모 데이터를 분석하고, 미시/거시 모델을 적용하여 그 예측력을 검증하고자 한다. 본 연구에서는 기존 방식으로 분석하던 Windows 기반의 E-Views 거시 분석 모형을 오픈소스 분석 플랫폼을 구축하고 이와 연계하여 결과를 도출하는 방안을 제시하고자 한다.

Influence of the CO2Concentration level on Sleep Quality (실내 CO2농도가 재실자의 수면의 질에 미치는 영향)

  • NA, LI;Han, Jin-kyu;Choi, Yoorim;Chun, Chung-yoon
    • Journal of Korean Living Environment System
    • /
    • v.19 no.4
    • /
    • pp.479-488
    • /
    • 2012
  • This study investigated the influence of the indoor CO2concentration level on sleep quality by polysomnography(PSG). One healthy female subject was selected among several subjects based on RI(Risk Indicator) value and BMI(Body Mass Index) value to evaluate judging the risk level of obstructive sleep apnea hypopnea. To get the impact of the indoor carbon dioxide concentration to sleep quality, both CO2concentration levels were set up using ventilating form with 700~800 ppm and 2000~3000 ppm. Other environments were controlled in the comfortable sleep scope by previous researches. To measure the sleep quality, measurements have carried on polysomnography(PSG). In conclusion, it have shown that high carbon dioxide concentration leads arousal effect about central nervous system and to sustaining dreams and excited condition by bring about REM sleep split phenomenon.

A Study on Fabrication of Monolithic Lightweight Composite Electronics Housing for Space Application (우주용 일체형 경량 복합재료 전자장비 하우징 제작에 관한 연구)

  • Jang, Tae Seong;Seo, Jung Ki;Rhee, Juhun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.12
    • /
    • pp.975-986
    • /
    • 2013
  • This paper dealt with the fabrication and performance evaluation of the electronics housing made of lightweight composite materials, aiming at the enhancement of satellite mass savings by replacing conventional aluminum alloy widely used for satellite avionics with lightweight composite material. For this purpose, a fabrication process was designed to overcome low machinability of CFRP and to minimize the post-treatment. The composite housing with grid-stiffened and monolithic frame was made using co-curing method. Its performance was also evaluated regarding endurance, stiffness, thermal conductivity, electrical grounding, EMI protection and radiation shielding. The composite housing can provide the considerable mass savings over the aluminum housing with same dimension.

An Analysis on the Accident Factors of the Housing Sold Guarantee in Housing Development Projects (주택분양사업장의 주택분양보증사고 발생요인 분석)

  • Kwak, Kyung-Seob;Baek, Sung-Joon
    • Journal of Cadastre & Land InformatiX
    • /
    • v.44 no.2
    • /
    • pp.231-242
    • /
    • 2014
  • On the Pre-Housing-Sale Systems there are many risks that developers might not fulfill the pre-sale obligations. In korea, in order to protect the people who bought houses from these risk, the Housing Sold Guarantee System was introduced and has been operated. Even though this system if there is accident in the pre-sale warranty business, several problems, such as damages caused to the people who bought the houses, occurs. Therefore, research is needed to Housing Sold Guarantee accident factor. But there are few study about it. This study attempted to analyze influencers on the possibility of the accident. We employ 3,026 data which Korea Housing Guarantee Co., Ltd manages and analyze them empirically, using business characteristics, housing market characteristics, and regional characteristics. Especially this study used to the binary logistic regression model. The results of analysis showed that the accident rate of Housing Sold Guarantee had been effected on the business type, house type, project financing guarantee, operator credit rating, housing market, and regional characteristics.

The Analysis of Pressure Relief Technology for ZnO Arrester (ZnO 피뢰기의 Pressure relief 기술 분석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Yoo, H.Y.;Kim, H.S.;Park, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1450-1452
    • /
    • 1998
  • The chief advantage of polymer arrester, from a handling viewpoint, design of pressure relief, anti-contamination, electrical failuer was reduced by polymer arrester. The life expectancy of polymer arrester depend on a number of design factor. This paper introduced and study : new material housing (silicone composite, EPDM, EPA...), cap type sealing structure, knuckle type electrode, stress relief housing, supporting insulator and sub parts, of polymer arrester.

  • PDF

Dielectric Properties of Rubber tutorials for Elbow Arrester Housing (ELBOW ARRESTER HOUSING용 고무절연재료의 절연특성)

  • Jeon, Young-Jun;Yoo, Jae-Il;Kim, Jin-Woo;Seo, Dong-Chul;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1265-1267
    • /
    • 1994
  • EPDM has excellent electric characteristics and so that it has been rapidly finding use is high voltage applications in recent years. At present EPDM is widely used for insulator of cable and accessories, and further the commercial use of Premolded housing for elbow surge arrester is started. In this paper, we have measured the temperature, pressure and voltages dependence of $tan{\delta}$ in EPDM. As a results, dielectric characteristics($tan{\delta}$) increases slightly with increasing the temperature. However, it is almost independent of the pressure and voltages.

  • PDF

The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students (대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태)

  • Choi, Yoon-Jung;Kim, Wn-Hak
    • Korean Journal of Human Ecology
    • /
    • v.19 no.4
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.