• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.03 seconds

Analyzing Leakage Defect Types in Educational Facilities and Deriving Key Management Strategies Using the FTA Method (FTA기법을 이용한 교육시설 누수 하자 유형 분석 및 주요 원인 관리방안 )

  • Jung, Daegyo;Park, Hyunjung;Lee, Dongyeop;Kim, Daeyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2024
  • In recent years, the construction industry has diligently focused on improving the quality and safety of buildings through smart technologies. However, there is a growing trend of leakage defects, especially in educational facilities, due to aging. The objective of this study is to analyze the causes of these defects in educational environments using the Fault Tree Analysis (FTA) technique and propose preventive measures based on the findings. The FTA technique is explained through a review of domestic literature, and data from the Educational Support Center from 2019 to 2021 are examined to identify major defects. The construction of the Fault Tree (FT) for leakage defects resulted in the identification of 12 basic events. Subsequently, a comprehensive understanding of the causes of leakage is achieved through FTA analysis, leading to the identification of the primary causes of defects. Leakage defects accounted for 46.8% of all reported issues in educational facilities, with roof (ceiling) leaks being the most common problem. FTA analysis revealed that poor substrate treatment was the main cause of roof (ceiling) leaks, which could be attributed to cracks in the waterproof layer, joint cracks, and microvoids in the waterproof layer. The primary achievement of this research is to provide essential data for preventing leakage defects in educational facilities and developing preventive measures through the FTA technique. These results are expected to significantly enhance the management of educational facilities and the prevention of leakage issues.

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Investigation of the Speech Intelligibility of Classrooms Depending on the Sound Source Location

  • Kim Jeong Tai;Haan Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.4E
    • /
    • pp.139-143
    • /
    • 2005
  • The present study aims to investigate the effects of speaker location on the speech intelligibility in a classroom. In order to this, acoustic measurements were undertaken in a classroom with three different sound source locations such as center of front wall (FC), both sides of front wall (FS) and the center of ceiling (CC). SPL, RT, $D_{50}$, RASTI were measured in the 9 measurement points with same sound power level of sound source and MLS was used as the sound source signal. Also, subjective listening tests were carried out using Korean language listening materials which were recorded in an anechoic chamber. The recorded syllables were replayed and recorded again in the classroom with same sound source at three different locations and listening tests were undertaken to 20 respondents who were asked to write the correct syllables which were recorded in the classroom. The results show that higher sound intelligibility ($D_{50}$ of $47\%$, RASTI of 0.56) was obtained when sound source was located at the FS. The results also show that high sound intelligibility was obtained at the area nearby walls.

Multiple Moving Person Tracking based on the IMPRESARIO Simulator

  • Kim, Hyun-Deok;Jin, Tae-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.877-881
    • /
    • 2008
  • In this paper, we propose a real-time people tracking system with multiple CCD cameras for security inside the building. The camera is mounted from the ceiling of the laboratory so that the image data of the passing people are fully overlapped. The implemented system recognizes people movement along various directions. To track people even when their images are partially overlapped, the proposed system estimates and tracks a bounding box enclosing each person in the tracking region. The approximated convex hull of each individual in the tracking area is obtained to provide more accurate tracking information. To achieve this goal, we propose a method for 3D walking human tracking based on the IMPRESARIO framework incorporating cascaded classifiers into hypothesis evaluation. The efficiency of adaptive selection of cascaded classifiers have been also presented. We have shown the improvement of reliability for likelihood calculation by using cascaded classifiers. Experimental results show that the proposed method can smoothly and effectively detect and track walking humans through environments such as dense forests.

  • PDF

A Study on the Implementation of BPSK Demodulator with Remodulation Method for Power Line Carrier Communication (전력선 통신용 재변조방식의 BPSK복조기 실현에 관한연구)

  • 오상기;나채동;진달복
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.38-45
    • /
    • 1994
  • It is very imprtant and necessary to predict luminous enviroment in an interior space. This paper has de scribed about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model w a m~a de and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. Ths paper suggests that basic fundamental data of lighting design ~rformancein the concept and schematic stages of design.

  • PDF

Analysis of Novel Helmholtz-inductively Coupled Plasma Source and Its Application for Nano-Scale MOSFETs

  • Park, Kun-Joo;Kim, Kee-Hyun;Lee, Weon-Mook;Chae, Hee-Yeop;Han, In-Shik;Lee, Hi-Deok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.35-39
    • /
    • 2009
  • A novel Helmholtz coil inductively coupled plasma(H-ICP) etcher is proposed and characterized for deep nano-scale CMOS technology. Various hardware tests are performed while varying key parameters such as distance between the top and bottom coils, the distance between the chamber ceiling and the wafer, and the chamber height in order to determine the optimal design of the chamber and optimal process conditions. The uniformity was significantly improved by applying the optimum conditions. The plasma density obtained with the H-ICP source was about $5{\times}10^{11}/cm^3$, and the electron temperature was about 2-3 eV. The etching selectivity for the poly-silicon gate versus the ultra-thin gate oxide was 482:1 at 10 sccm of $HeO_2$. The proposed H-ICP was successfully applied to form multiple 60-nm poly-silicon gate layers.

A Study on the Development Type of Component Joint Design for Environment Friendly Multi Housing Remodeling (공동주택의 친환경 리모델링을 위한 부품접합부 개선방안의 유형화에 관한 연구 II;욕실 및 주방을 중심으로)

  • Lim, Seok-Ho;Kim, Soo-Am;Hwang, Eun-Kyoung;Yun, Mae-Han
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.370-373
    • /
    • 2006
  • Lastly, the problem of filling occurs in the process of concealed joint of adjacent components and was seen in joints between the structure and an electrical or mechanical device. Therefore, the dry processing which replaces wet joint was seen in joints between the structure and a door, ones between the structure and a finishing materials, ones between a gypsum board and electrical device, and ones between a water pipe and a tile finishing. And a process of separating the area of jointed parts in order to eliminate the problem of overlap was seen in joints between a door and a finishing material and ones between a gypsum board on the ceiling and a light. Lastly, an analysis of a process of exposing concealed parts indicated that the problem of filling could be applied to joints between the structure and an electrical or mechanical device and ones between a finishing material and a mechanical device. This study sought out methods to apply Environment Friendly Multi Housing Remodeling that allow easy remodeling as part of environment- preserving policies. It also contains basic data useful to implement long-life houses in the future by presenting a comprehensive design standard for them

  • PDF

Analyses on Daylight Variations for Optimum Controls of Daylight Dimming Systems in a Small Office (소규모 사무실에 적용된 조광제어 시스템의 최적제어를 위한 주광변화 분석)

  • Yoon, Youn-Ju;Baik, Yong-Kyu;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.433-442
    • /
    • 2012
  • The influence of outdoor sky conditions on photosensor signals were examined to determine an appropriate index that is effectively used for optimum illuminance fluctuation when a daylight dimming system is used for a small office. Field measurements were conducted under various sky conditions. Results indicate that the outdoor global and vertical illuminance fluctuated within narrow ranges under clear and overcast sky conditions. The fluctuation of sky ratio under partly-cloudy sky caused wide ranges of illumnance fluctuation. A partially-shielded photosensor at backwall produced 56% of light output from fixtures controlled by a photosensor at ceiling. This implies that the photosensor at backwall does not always guarantee target illuminance due to the less output. The fluctuation of light output from fixtures were insignificant under clear and overcast sky. The fluctuation range of photosensor illuminance under partly-cloudy sky caused wide fluctuation ranges of light output. Regression result implies that the outdoor vertical illuminance was recommended for an effective index that is used for control of light output.

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting (자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han;Han, Sang-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

The Characteristics of Comtemporary Expression of Traditional Space Components Appearing in Indonesian Restaurants (인도네시아 레스토랑에 나타난 전통 공간구성요소의 현대적 표현 특성)

  • Kang, Yu-Na;Oh, Hye-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.254-261
    • /
    • 2011
  • The purpose of this study was to investigate the characteristic as to how the Indonesian traditional space is expressed in a contemporary space. As for the study method, We visited 12 Indonesian restaurants in Jakarta from Oct. 16 to Oct. 20, 2010 for a case study. The study result is presented as follows: First, as a factor of facade components, the roof part revealed its identity as a Joglo structure. Walls, windows and doors reflected Indonesian tradition, or were transformed in passive or aggressive ways. Second, as a factor of interior space components, ceilings were predominantly designed by reflecting a structural exposure ceiling or Tumpang Sari as it was or by passively transforming them; Interior walls, windows and doors were transformed in aggressive ways. Third, regarding the factors of interior decoration components, traditional furniture was not used, but instead, furniture with contemporary form and local materials were dominently used, and traditional accessaries were used as they were. Therefore, in the case of designing spatial componentss in Indonesian restaurants located in Jakarta, roofs and ceilings, floors, furniture, and accessaries reflected Indonesian tradition, or were passively transformed, whereas walls, windows, doors, and some ceilings aggressively reflected modernized tradition so that they were formed in harmony with traditional and contemporary styles.