• 제목/요약/키워드: capacitance measurement method

검색결과 139건 처리시간 0.026초

Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS

  • Kim, J.H.;Kim, S.S.;Kim, S.H.;Baik, S.W.;Jeon, G.R.
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.1-7
    • /
    • 2016
  • Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of $800{\mu}A$ was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human's popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was $7.8^{\circ}$ slightly larger than $7.6^{\circ}$ at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were $1664.14{\Omega}$ and $1614.08{\Omega}$, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane.

S-파라메타를 이용한 절연 변압기의 고주파 파라메타 추출 (High-Frequency Parameter Extraction of Insulating Transformer Using S-Parameter Measurement)

  • 김성준;류수정;김태호;김종현;나완수
    • 한국전자파학회논문지
    • /
    • 제25권3호
    • /
    • pp.259-268
    • /
    • 2014
  • 본 논문에서는 S-파라메타를 이용한 절연 변압기의 고주파 파라메타 추출 방법을 제안한다. 정상상태에서 회로상수 추출은 고전적 방법인 무 부하, 단락 회로 시험을 통해 나온 측정값을 계산하여 추출하는 방법이 있으며, 본 논문에서는 VNA(Vector Network Analyzer)로 측정한 S-파라메타를 이용하여 추출하는 방법에 대한 연구를 수행하였다. 상용주파수인 60 Hz를 포함한 고주파 대역에서의 변압기 회로상수는 측정한 S-파라메타에 데이터 피팅(최적화) 방식을 이용하여 추출하였다. 기본적으로 절연변압기에서의 고주파 파라메타 추출은 기존에 제시하는 변압기 등가 회로에 표유정전용량(Stray capacitance)을 추가한 등가회로 형태로 제시된다. 이렇게 추출한 회로상수의 S-파라메타와 실제 측정한 S-파라메타 결과를 비교하여 유사함을 확인하였고, 변압기의 1차 측에 신호발생기를 입력한 후, 출력되는 2차 측의 전압과 고주파 등가회로를 이용하여 추출한 2차 측 전압을 비교하여 두 값이 일치하는 것을 확인하였다. 이 결과를 통해 S-파라메타를 이용한 절연 변압기의 고주파 파라메타 추출 방법의 타당성을 입증하였다.

저압충격을 이용한 변압기에서 권선변형 측정 (Measurement of winding deformation in transformers using low voltage impulse)

  • 조국희;강동식;김광화;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.388-390
    • /
    • 1997
  • We describe the characteristic of LVI(Low-voltage Impulse) test system and methods to detect the deformation of windings in the power transformers. Any winding deformation will result in a change of capacitance between winding parts and possibly some change in the winding inductance. These changes will then result in a change in the responce to the applied pulse in both the magnitude and period of the resulting oscillations. A results of measured differential method in stead of typical method, the sensitivity is greatly improved by the use of differential methods where the pulse is applied to two identical windings and the response measured with a differential amplifier.

  • PDF

Conductance 법에 의한 MNS Diode 의 계면상태에 관한 고찰 (Study on the Interface State Density of MNS Diode by the Conductance Method.)

  • 설영권;최종일;이내인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.346-349
    • /
    • 1988
  • Conductance technique is the moat accurate method and gives more detailed information about interface of the MIS structure than other methods. With the measurement of the equivalent parallel conductance and capacitance, the characterization of Si-SiN interface is developed. The interface state density of Si-SiN is obtained by $8{\times}10^{11}$ - $6{\times}10^{12}(eV^{-1}cm^{-2}$). After the positive B-T stress is performed on the sample, the interface state density gets increased. The interface state density is not effected by the D.C. stress.

  • PDF

포텐티오메트릭 4-전극 용기에 의한 전도도 측정 (Electrolytic Conductance Measurement using Four-Electrode Cell and Potentiometric Circuit)

  • 천정균;백운기
    • 대한화학회지
    • /
    • 제20권2호
    • /
    • pp.129-135
    • /
    • 1976
  • 4-전극 측정 용기와 정전위 전자회로를 써서 직독식 전기전도도 측정장치를 고안하여 KCl, HCl등 전해질 용액의 전기전도도를 측정하였다. 이 장치는 상용되고 있는 브릿지회로와 2-전극 용기를 쓰는 방법에서 당면하는 어려운 문제들, 특히 전극에서의 전기 이중층의 존재와 파라디임피던스 등으로 나타나는 전기화학적으로 복잡한 성질들로 인한 문제들을 피하여 정밀하고 간편한 측정에 쓰이도록 만들었다.

  • PDF

고주파수분센서(FDR)를 활용한 콘크리트 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Concrete Unit-Water Content Using High Frequency Moisture Sensor (FDR))

  • 이승엽;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2021
  • The unit-water content has a major problem in concrete structures which leads to micro cracks on the concrete during drying time. Thus, the compressive strength and durability of the concrete structures are significantly reduced. Several techniques have been developed to measure the unit-water content in concrete structures such as heating drying, unit volume mass, and capacitance measurements. However, these techniques have problems in during measurement such as longer time, expensive and difficult in analysis of data. Frequency Domain Reflectivity (FDR) is one of the sensors which used to measure the water content. This method has several advantages including easy to measure, inexpensive, and capable of measuring moisture in real time. In this study, an attempt has been made to evaluate the unit-water content in concrete using the FDR sensor and interpret the data with deep learning method.

  • PDF

고주파수분센서를 활용한 분체 비율별 모르타르 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mortat Unit-Water Content by Powder Ratio Using Frequency Domain Reflectometry Sensor)

  • 윤지원;이승엽;위광우;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2022
  • Currently, interest in the quality of concrete is increasing. Among the important factors for evaluating the quality of concrete, interest in unit-water content is also increasing. Currently, the air-meter method, the microwave oven drying method, the capacitance method, and the microwave penetration method are used to measure the unit-water content of concrete.. Among the above methods, except for the microwave method, the measurement method is complicated, portability is reduced, and economic efficiency is reduced. This research aims to measure a unit-water content by using a Frequency Domain Reflectometry(FDR) sensor that is economical, simple to measure, and portable among microwave methods. In addition, it is an experimental study to determine the accuracy of unit-water content using a single input residual model during deep learning to solve the limitations of the FDR sensor.

  • PDF

체표 캐패시턴스 측정 방식을 이용한 체표 경락.경혈 에너지 변화 분석 (Analysis of Meridian Energy and its Change Pattern with Time using Measurement of Skin-Capacitance on Source Points)

  • 김수병;권선민;명현석;이경중;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제26권3호
    • /
    • pp.1-11
    • /
    • 2009
  • Objectives : The object of this study is to investigate the balance/imbalance of skin capacitances between left and right meridians, and to analyze the change patterns of electric energy on meridians with the lapse of time. Method : Electric potential was measured on five source points (LU9, PC7, HT7, LI4, SI4) bilaterally for 4 hours. The energy balance/imbalance between left and right was investigated, and the change patterns with time were analyzed. Results and Conclusions : The amplitude of meridian energy on five source points and the energy balance/imbalance between left and right were varied in each individual. When a source point showed a balanced meridian energy bilaterally, the change patterns of meridian energy with time were similar between left and right. While, when it showed an imbalanced energy between left and right, the change patterns of meridian energy were also different between left and right. Through this study, we proposed a new diagnostic method of meridian energy.

  • PDF

전달 행렬 방법을 이용한 Schottky 다이오드 자외선 광검출기의 물질특성 추출과 설계 (Extraction of Material Parameters and Design of Schottky Diode UV Detectors Using a Transfer Matrix Method)

  • 김진형;김상배
    • 대한전자공학회논문지SD
    • /
    • 제43권5호
    • /
    • pp.25-33
    • /
    • 2006
  • 전달 행렬 방법과 capacitance-voltage 특성, 그리고 측정된 광응답 스펙트럼을 이용하여 Schottky 다이오드 UV-A와 B 광검출기에 사용되는 GaN, $Al_{0.2}Ga_{0.8}N$ 등의 반도체 및 Schottky 접촉 금속 Ni의 물질특성인 흡수계수(absorption coefficient)를 추출하였다. 입사된 빛이 반도체의 공핍영역에서 흡수되는 양을 구하고, 이로부터 각 파장에서의 광응답 특성을 얻는 과정을 컴퓨터 프로그램으로 구현하였다. 그리고, 계산 값을 측정치와 비교하여 각 파장에서 GaN, $Al_{0.2}Ga_{0.8}N$, Ni의 흡수계수를 얻을 수 있었다. 추출된 흡수계수를 이용하여 자외선 광검출기의 광응답을 높이는 설계 방안을 모색하였다. Ni의 흡수계수가 크기 때문에 광응답을 결정하는 주요 요소는 Ni 전극의 두께이다. 따라서 Schottky 접촉 금속 Ni의 두께를 줄이고, 공핍 영역의 크기를 늘릴 수 있다면 광응답 특성이 더욱 향상된 광검출기의 실현이 가능해질 것이다.

자동차 엔진오일 열화상태 in situ 측정용 전기용량 센서 (Capacitive Sensor for in situ Measurement of Deterioration of Car Engine Oil)

  • 이래덕;김한준;세메노프
    • 센서학회지
    • /
    • 제10권4호
    • /
    • pp.266-272
    • /
    • 2001
  • 자동차 엔진오일의 열화상태를 직접 in situ로 측정할 수 있는 코일형 전기용량 센서를 개발하였다. 엔진 오일팬의 드레인 홀의 제한된 공간 속에서 10 pF 이상을 얻기 위하여 코일형으로 설계 제작되었다. 코일의 직경 및 권선 조건, 포머의 재질 및 구조, 차폐조건 등 안정된 전기용량 측정을 위한 설계 요구 조건을 컴퓨터 시뮬레이션과 실험적인 방법에 의해서 찾아내었다. 제작된 여러 개의 센서를 이용하여 동일한 조건의 사용오일 특성을 분석한 결과 0.25% 이내에서 일치하였다. 차량에 직접 장착하여 장기간 측정한 결과, 심한 진동과 온도 및 습도변화와 전자기적 잡음 등 열악한 차량의 조건에서도 매우 우수한 측정결과를 나타내었다.

  • PDF