An Experimental Study on the Evaluation of Concrete Unit-Water Content Using High Frequency Moisture Sensor (FDR)

고주파수분센서(FDR)를 활용한 콘크리트 단위수량 평가에 관한 실험적 연구

  • 이승엽 (한양대학교 스마트시티공학과) ;
  • 양현민 (한양대학교 건축공학과) ;
  • 이한승 (한양대학교 건축공학과)
  • Published : 2021.11.12

Abstract

The unit-water content has a major problem in concrete structures which leads to micro cracks on the concrete during drying time. Thus, the compressive strength and durability of the concrete structures are significantly reduced. Several techniques have been developed to measure the unit-water content in concrete structures such as heating drying, unit volume mass, and capacitance measurements. However, these techniques have problems in during measurement such as longer time, expensive and difficult in analysis of data. Frequency Domain Reflectivity (FDR) is one of the sensors which used to measure the water content. This method has several advantages including easy to measure, inexpensive, and capable of measuring moisture in real time. In this study, an attempt has been made to evaluate the unit-water content in concrete using the FDR sensor and interpret the data with deep learning method.

Keywords

Acknowledgement

이 연구는 2021년도 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업이다. (No.2015R1A5A1037548)