• Title/Summary/Keyword: camera exposure

Search Result 166, Processing Time 0.026 seconds

Chip stack height measurement of semiconductor using slit beam (슬릿빔을 이용한 반도체의 칩 적층 높이 측정)

  • Shin, Gyun-Seob;Cho, Tai-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.422-424
    • /
    • 2009
  • In this paper, we studied methods that measure chip stack height using slit beam in mold equipment among semiconductor manufacture equipments. We studied two methods to improve chip stack height measurement performance. First, it is relation of camera exposure time and height measurement repeatability. Second we could improve measurement performance applying method of least mean square method for measurement error minimization about PCB(Printed Circuit Board) flexure phenomenon.

  • PDF

Spatiotemporal Patched Frames for Human Abnormal Behavior Classification in Low-Light Environment (저조도 환경 감시 영상에서 시공간 패치 프레임을 이용한 이상행동 분류)

  • Widia A. Samosir;Seong G. Kong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.634-636
    • /
    • 2023
  • Surveillance systems play a pivotal role in ensuring the safety and security of various environments, including public spaces, critical infrastructure, and private properties. However, detecting abnormal human behavior in lowlight conditions is a critical yet challenging task due to the inherent limitations of visual data acquisition in such scenarios. This paper introduces a spatiotemporal framework designed to address the unique challenges posed by low-light environments, enhancing the accuracy and efficiency of human abnormality detection in surveillance camera systems. We proposed the pre-processing using lightweight exposure correction, patched frames pose estimation, and optical flow to extract the human behavior flow through t-seconds of frames. After that, we train the estimated-action-flow into autoencoder for abnormal behavior classification to get normal loss as metrics decision for normal/abnormal behavior.

Toxicity and Behavioral Changes of Medaka (Oryzias latipes) by Brine Exposure (송사리(Oryzias latipes)를 이용한 고염해수의 생태독성 및 단기적 행동변화에 관한 연구)

  • Yoon, Sung-Jin;Park, Gyung-Soo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.1
    • /
    • pp.39-51
    • /
    • 2011
  • Acute toxicity test and behavioral change analysis of seawater acclimated Japanese medaka were conducted to identify the brine effects on fish by seawater desalination. 7 day acute toxicity test of brine revealed linear concentration-response relationship from 40.0~80.0 psu treatment groups. There was no significant brine effect for 30-40 psu groups and mass mortality was observed from >50 psu exposure (7-day $LC_{50}$=51.4 psu). Images from the real time camera system were analyzed to observe the changes in behavioral patterns of medaka exposed to various salinity. 40.0 and 50.0 psu exposed groups were stabilized in behavioral patterns after 3.1 and 4.6 hours, respectively and 60.0 psu group showed sharp increase in activity during first 12 hours and 50% mortality thereafter. Similar patterns were observed to 70 and 80 psu groups and both experimental groups showed 100% mortality within 12 hours. Acute toxicity test and behavioral patterns showed very similar toxicity results which revealed the increases in mortality and behavioral activities from 50.0 psu. This critical salinity for fish impacts must be implemented to brine discharge strategy by seawater desalination into the coastal area. Also, we recommend that real time camera monitoring system must be a useful tool for early warning of fish toxicity for other applications. This research was funded by Ministry of Land, Transport and Maritime Affairs, Korea.

Estimation of Differently Exposed Low Dynamic Range Images from a Single Bayer Image (단일 Bayer 영상으로 부터 다양한 노출을 가지는 Low Dynamic Range 영상들의 추정)

  • Lee, Tae-Hyoung;Ha, Ho-Gun;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • HDR(high dynamic range) imaging techniques supports wider dynamic range than normal images captured from general still camera. These usually need several shots to obtain LDR(low dynamic range) images, causing ghosting artifacts. Accordingly, this paper suggests a method to generate new LDR images from a single Bayer image using Exposure LUT(look-up table) by considering channel dependency. We prior construct exposure LUT for each RGB channel, showing the relationship between input and average output luminance values. In the process, by applying the average luminance of input image and current exposure to LUT, new exposures which are determined by user choice are first estimated. Next, LDR images which are corresponded to new exposures are generated based on each LUT. Saturated areas are improved by considering channel dependency in the last procedure. In the experimental comparison, high PSNR values are obtained between estimated and captured images. Also, we have similar appearance on displayed images.

Calculation of Buildlng Heights from a Single Satellite Image (고해상도 단일 위성영상으로부터 건물높이값 추출)

  • 이병환;김정희;박경환
    • Spatial Information Research
    • /
    • v.7 no.1
    • /
    • pp.89-101
    • /
    • 1999
  • This paper represents methods to calculate heights of buildings by estimating their shadow lengths in a single and panchromatic image of the KVR-1000 camera system Shadows are identified Com brightness intensity of each pixel, and their lengths are measured. Two methods are implemented to estimate heights from shadows. One method is to use a ratio of shadow s lengths with respect to heights of reference buildings measured on site. The other method uses sun elevation angles calculated from various camera s parameters at the exposure time. The estimated heights of 20 buildings are compared with heights measured on site, and the RMS errors for each method are 1.70m and 1.75m, respectively. When a resampling method to enhance identification of shadows is used and their lengths are accordingly re-calculated, the estimated errors for each method are significantly reduced to 1.17m and 1.16m, respectively. Meanwhile, effects of land slope on shadows can be hardly obtained unless detailed DTM(digital terrain model) are available, and they introduce additional errors up to 25m.

  • PDF

Auto-Guiding System for McDonald Otto Struve Telescope

  • Kim, Eun-Bin;Park, Won-Kee;Kim, Jin-Young;Oh, Hee-Young;Choi, Chang-Su;Pak, Soo-Jong;Im, Myung-Shin;Kuehne, John
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.38.1-38.1
    • /
    • 2010
  • McDonald 2.1m Otto Struve Telescope is located in the Davis Mountains, 450 miles west of Austin, Texas. The telescope was built in 1938, but it is still in demand today. CQUEAN (Camera for QUasar in Early uNiverse) will be attached on this telescope and perform Y-band imaging observations. Dynamics study of the telescope shows that tracking errors are 0.1 arcsec/100sec in declination direction and 0.4 arcsec/100sec in R.A. direction. In order to allow a long exposure (> a few minutes) of a target field, we are making auto-guiding system for the 2.1m telescope. The auto-guiding system of CQUEAN will be connected with TCS of the telescope. The expected number of stars on the CCD field (2.97 square arcminutes) is about 1.2 stars which are brighter than magnitude 17.5 in 2.97 square arcminutes. For more effective observation, we plan to implement moving mechanism in guiding system so that guide CCD camera can see wider off-axis fields.

  • PDF

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Blurred Image Enhancement Techniques Using Stack-Attention (Stack-Attention을 이용한 흐릿한 영상 강화 기법)

  • Park Chae Rim;Lee Kwang Ill;Cho Seok Je
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.2
    • /
    • pp.83-90
    • /
    • 2023
  • Blurred image is an important factor in lowering image recognition rates in Computer vision. This mainly occurs when the camera is unstablely out of focus or the object in the scene moves quickly during the exposure time. Blurred images greatly degrade visual quality, weakening visibility, and this phenomenon occurs frequently despite the continuous development digital camera technology. In this paper, it replace the modified building module based on the Deep multi-patch neural network designed with convolution neural networks to capture details of input images and Attention techniques to focus on objects in blurred images in many ways and strengthen the image. It measures and assigns each weight at different scales to differentiate the blurring of change and restores from rough to fine levels of the image to adjust both global and local region sequentially. Through this method, it show excellent results that recover degraded image quality, extract efficient object detection and features, and complement color constancy.

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department (핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰)

  • Yoo, Jae-Sook;Jang, Jeong-Chan;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • Purpose: Those who access to the nuclear medicine department are classified as radiation workers, temporarily access group, and occasional access group as defined by the atomic energy law. The radiation workers and temporarily access people wear a personal radiation dosimeter for checking their own radiation absorbed dose periodically. However, because of the sanitation workers, classified as temporarily access group, who are working in the nuclear medicine department are moved in a cycle with other departments and their works are changeful, it is hard to control their radiation absorbed dose. Thus, this study is going to examine the state of the sanitation worker's radiation absorbed dose, and then make sure whether they are classified as temporarily access group or not. Materials and methods: In the first instance, the first sanitation worker who works in vitro laboratory and PET room and the second sanitation worker who works in gamma camera rooms (invivo room) wore radiation dosimeter-OSL(Optically Stimulated Luminescence)- to measure their own radiation absorbed dose during work time from May to June 2011. Secondly, this study was taken place 5 places in gamma camera rooms, 2 places in PET bed room, operating room, waiting room and cyclotron room in PET and 4 places in vitro laboratory. And then to measure the radiation space dose rate, it is measured 10 times each of places as sanitation worker's work flow by using radiation survey meter. Results: The radiation absorbed dose on OSL of the first c who works in vitro laboratory and PET room and the second one who works in gamma camera rooms are 0.04, 0.02 mSv per month respectively. That means the estimated annual radiation absorbed doses are less than 1mSv as 0.48, 0.24 mSv/yr respectively. The radiation space dose rates as sanitation worker's work flow using survey meter are 0.0037, 0.0019 mSv/day, so the estimated annual radiation absorbed dose are 0.93, 0.47 mSv/yr respectively. The weighted exposure dose of first sanitation worker of each places are 1.62% in cyclotron room, 3.88% in waiting room, 2.39% in operating room, 81.01% in bed room of PET and 11.01% in vitro laboratory. The weighted exposure dose of second sanitation worker of each places are 45.22% in radiopharmaceutical laboratory, gamma 30.64% in camera rooms, 15.65% in waiting room, 8.49% in reading room. Conclusion: The annual radiation absorbed doses on OSL of both sanitation workers are less than 1 mSv per year and the annual radiation absorbed doses by using survey meter are less than 1mSv either, but close up to 1 mSv. Thus, to clarify whether the sanitation workers are temporarily access group or not, and to be lessen their s radiation absorbed dose, they should be educated about management of radiation and modified their work flow or work time appropriately, their radiation absorbed dose would be lessen certainly.

  • PDF