• Title/Summary/Keyword: bubbles

Search Result 879, Processing Time 0.026 seconds

Research on the Microstructure and Features of Pottery Excavated from Gijang-gun, Busan, South Korea (기장군출토 도자기의 미세구조 및 특성에 관한 연구)

  • Hong, Jong Ouk;Han, Min Su
    • 보존과학연구
    • /
    • s.33
    • /
    • pp.109-124
    • /
    • 2012
  • Jangan-eup, located in Busan, South Korea,is a famous pottery-producing area in the Joseon Dynasty period. The aim of this paper was to determine the correlation of the pottery from each kiln site of Jangan-eup by analyzing the ingredients of clay as well as its production technique and firing condition. The materials that were used for the study were fragments of inlaid celadon, white porcelain, and white porcelain painted with underglazed iron excavated from six kiln sites of Jangan-eup:Sil-li, Daeryong-li, Hajangan-li, Sangjangan-li, Yongso-li, and Dumyeong-li. In each of the samples from the six kilns, cristobalite, mullite, and quats were found. The firing temperature distinguished from the crystal structure was higher in the following order: Dumyeongli>Sangjangan-li>Daeryong-li>Hajangan-li>Yongso-li>Sil-li. The samples were divided into four groups based on the ingredients of the clayfound therein: the Sil-li andDaeryong-li group, the Hajangan-li and Sangjangan-li group, the Yongso-li group, and the Dumyeong-li group. It was also found that the sample of Dumyeong-li was made using the most homogeneous clay compared with the other samples. The pottery of Jangan-eup had $40-400{\mu}m$ glaze, had bubbles in their bodies, and had $10-150{\mu}m$ sizes.

  • PDF

Spectrophotometric Determination of Traces of Phosphorus in Semiconductor-grade Trichlorosilane (반도체급 삼염화실란 중의 극미량 인의 분광광도법적 정량)

  • Dong Kwon Kim;Myoung Wan Han;Hee Young Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.255-260
    • /
    • 1992
  • A procedure for spectrophotometric determination of traces of phosphorus(P) in high-purity trichlorosilane(TCS) is proposed using an adsorptive separation. $PCl_3$, which is a dominant P impurity within TCS, is first oxidized by oxygen to a stable form as $POCl_3$. $AlCl_3$ is selected as an adsorbent which forms a thermally stable complex with $POCl_3$ in TCS and can be well dissolved in aqueous ethanol solution. The proposed adsorptive separation method is free from the formation of silica gel and gas bubbles during the colorimetric analysis of TCS. The method reveals that the P concentration in a semiconductor-grade TCS is 5.32 ${\mi}g/l$ within the standard deviation of ${\pm}$ 17%. On the other hand, the P concentration of the purified TCS which is separated from the $AlCl_3$${\cdot}$$POCl_3$ complex is reduced to be less than 0.15 ${\mi}g/l$, showing the efficient applicability of $AlCl_3$ to the wet chemical analysis. The proposed method is also tested to verify the effectiveness of other well-known adsorbents.

  • PDF

Analysis of Voltaic Cell Described in the Science Textbooks of Secondary Schools (중·고등학교 과학 교과서에 제시된 볼타전지에 대한 문제점 분석)

  • Sin, Dong-Hyeok;Lee, Sang-Gwon;Choe, Byeong-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.363-377
    • /
    • 2002
  • The purpose of this study was to improve the problems of the voltaic cell described in the science textbooks of secondary schools. For this purpose, the contents of science textbooks which are related to the voltaic cell were analyzed and the problems which were not explained clearly by theorems were tried to be explained by experiments, and lastly sug-gestions were made toward the improvements regarding the voltaic cell in the science textbooks. The findings are that there are problems on the ways of ensuring whether the voltaic cell operates properly as a chemical battery, on the explanation of why the hydrogen bubbles form at the zinc electrode, on the cell potential, on the unification of the electrode terminology used, and on the mention of the current. Solutions to the problems except the cell potential were suggested. According to the experiment, the theoretical potential was calculated by considering the potentials of redox reactions at the two electrodes of the cell and by taking into account the characteristics of the electrodes such as the work function, ionization energy, stan-dard reduction potential, and electronegativity.The cell potential of the voltaic cell is explained by several factors. In the improved version of the textbook's introduction section to the voltaic cell, it is necessary to describe the voltaic cell his-torically.For the conceptual section, it should be explained in terms of the Daniel cell.

Experimental Investigation of the Combined Effects of Heat Exchanger Geometries on Nucleate Pool Boiling Heat Transfer in a Scaled IRWST (열교환기 형상이 축소한 IRWST 내부의 풀핵비등에 미치는 복합적인 영향에 대한 실험적 연구)

  • Kang, Myeong-Gie;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • In an effort to determine the combined effects of major parameters of heat exchanger tubes on the nucleate pool boiling heat transfer in the scaled in-containment refueling water storage tank (IRWST), a total of 1,966 data for q'quot; versus ${\Delta}T$ has been obtained using various combinations of tube diameters, surface roughness, and tube orientations. The experimental results show that (1) increased surface roughness enhances heat transfer for both horizontal and vertical tubes, (2) the two heat transfer mechanisms, i.e.,enhanced heat transfer for both horizontal and vertical tubes, (2) the two heat transfer mechanisms, i.e., enhanced heat transfer due to liquid agitation by bubbles generated and reduced heat transfer by the formation of large vapor slugs and bubble coalescence are different in two regions of low heat fluxes (q'quot; $\leq$50kW/$m^2)$ and high heat fluxes (q'quot; $\geq$50kW/$m^2)$ depending on the orientation of tubes and the degree of surface roughness, and (3) the heat transfer rate decreases as the tube diameter is increased for both horizontal and vertical tubes, but the effect of tube diameter on the nucleate pool boiling heat transfer for vertical tubes is greater than that for horizontal tubes. Two empirical heat transfer correlations for q'quot;, one for horizontal tubes and the other for vertical tubes, are obtained in terms of surface roughness $({\varepsilon})$ and tube diameter (D). In addition, a simple empirical correlation for nucleate pool boiling heat transfer coefficient $(h_b)$ is obtained as a function of heat flux (q'quot;) only.ucleate pool boiling heat transfer coefficient $(h_b)$ is obtained as a function of heat flux (q'quot;) only.

  • PDF

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Youth Startup Firms: A Case Study on the Survival Strategy for Creating Business Performance (청년창업기업의 창업초기 생존전략 : 중진공 청년전용자금 활용기업 사례)

  • Lee, Seung-Chang;Lim, Won-Ho;Suh, Eung-Kyo
    • Journal of Distribution Science
    • /
    • v.12 no.6
    • /
    • pp.81-88
    • /
    • 2014
  • Purpose - Entrepreneurship promotion is emerging as an important economic growth agenda. However, in Korea, entrepreneurship has weakened because of the collapse of the venture bubbles of the 2000s and the global economic recession in 2008, which have induced the business community to choose stability over risk. The Korean government has been implementing several support projects to inspire and promote youth entrepreneurship through various means including financial assistance; however, the perpetuation rate of young entrepreneurship is still low as compared to advanced economies such as the US and EU. This case study focuses on the Youth Start-Up Business Support Program of the Small & Medium Business Corporation, and explores practical alternatives. Further, it aims to suggest managerial factors and a conceptual model for change management factors affecting the business performance creation of a startup company, based on the Small and medium Business Corporation's young venture startup fund. Research design, data, and methodology - Many studies examine the current progress and issues of startup firms, for example, a lack of systematic cultivation of entrepreneurship and startup business training, lack of commercialization funding for youth startup businesses, lack of mentoring, and inadequate infrastructure. From prior research, we address four factors, namely, personal managerial capabilities, innovative business model, sufficient cash flow, and social network, affecting startup companies' business performance. This study involved a sample survey of 200 young entrepreneurs to investigate casual relations between the four factors and business performance. A regression analysis was used to verify the hypotheses. Results - First, in relation to differences in the founder's personal characteristics, age, sales amount, and number of employees significantly impact business performance. Second, regarding the causal relation between the four factors for creating business performance, an innovative business model and social networking have supported the hypotheses, revealing that the more that a start-up founder has an innovative business model and social networking, the more the start-up firms are likely to have better performance (e.g., sales volume, employment, ROE, ROI, etc.). Although the founder's competency and sufficient cash flow have no significant relationship with business performance, the mean value was higher performance for high founder's competency and sufficient cash flow. Conclusions - This study provides basic data on policy support strategies of the Small and Medium Business Corporation, to help young entrepreneurs achieve their start-up business goals. It shows that young entrepreneurship startup firms should strive to explore ideas to satisfy customers' needs, and that changes in customer value and the continuous innovation of business model differentiation are required to actively respond to change management. Moreover, at the infant startup stage, they should activate social network programs to share information, thereby offsetting resource scarcity and managing business risk. Further, the establishment of a long-term vision and the implementation of training programs in related specific fields should be supported to strengthen founders' personal capabilities.

Application of Precipitate Flotation Technique to Separative Preconcentration and Determination of Arsenic in Water Samples (물시료 중 비소의 분리 정량을 위한 침전 부선기술의 응용)

  • Park Sang-Wan;Choi Hee-Seon;Kim Young-Man;Kim Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.389-396
    • /
    • 1991
  • The pre-concentration and determination of ultratrace arsenic in water samples was studied by the precipitate flotation technique. The arsenic in 1.0l of water sample, in which all suspended materials were filtered out, was coprecipitated together with La(OH)$_3$ precipitates at pH 8.5${\pm}$0.1. After the precipitate was made to be hydrophobic by adding mixed surfactant of 1 : 8 mole ratio of sodium oleate and sodium dodecyl sulfate, it was floated with the aid of tiny bubbles of nitrogen gas in a flotation cell. The floated precipitate was quantitatively collected on a micropore glass filter by the suction, dissolved with small volume of 1.0M sulfuric acid, and accurately diluted to 25.00ml with a de-ionized water. Total arsenic was spectrophotometrically determinated by forming silver diethyldithiocarbamate complex of arsine generated from arsenic in the concentrated solution. The calibration curve was linear up to 20ng/ml in the original solution. Analytical results showed that contents of arsenic in a campus wastewater and a river water were 8.2ng/ml and l.0ng/ml, respectively, and their recoveries were 93${\%}$ and 90${\%}$ in water samples which a given amount of arsenic was added into. From above result, it could be concluded that this method was applicable to the determination of arsenic in various kinds of water at low ng/ml levels.

  • PDF

Separation and Concentration of Trace Mercury [Hg(II)] in Water Sample by Coprecipitation Flotation Technique (공침-부선기술에 의한 수용액 시료 중 흔적량 수은 [Hg(II)]의 분리 및 농축)

  • Lee Kang-Seok;Choi Hee-Seon;Kim Seon-Tae;Kim Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.355-361
    • /
    • 1991
  • The separative preconcentration of trace mercury[Hg(II)] in a water sample was studied by a coprecipitation flotation technique. The trace Hg(II) was precipitated together with Ce(OH)$_3$ by adding 3.0 ml of 0.1M Ce$^{3+}$ solution to 1,000 ml of water sample and adjusting pH to 11.0 with 1.0M NaOH solution. The hydrophobic precipitate[Ce(OH)$_3$-Hg(OH)$_2$], which was formed by adding 2.0 ml of 0.1${\%}$ ethanolic sodium oleate solution, were floated on the surface with an aid of tiny nitrogen gas bubbles. The floated materials were quatitatively collected in a suction flask and dissolved with 5.0 ml of 2.0M HNO$_3$. The solution was marked to 25.00 ml with a deionized water. The content of Hg(II) was determined by cold vapor atomic absorption spectrophotometry. Any interferences of concomitants such as Ag$^+$, Br$^-$, I$^- $, etc. were not observed on the whole procedure. The analytical result showed that Hg(II) found in the wastewater of Seochang Campus, Korea University was 1.98 ng/ml with the relative standard deviation of 3.6${\%}$. And recoveries of Hg(II) in the wastewater into which 1.0 ng/ml and 2.0 ng/ml were added were 95${\%}$ and 91${\%}$, respectively. From such results, this procedure could be concluded to be tolerably accurate and reproducible for the determination of trace mercury in a water sample.

  • PDF

A Study on the Performance of Foamed Concrete for Cores Material of Metal Vacuum Insulation Panel (금속진공단열패널의 심재용 기포콘크리트의 성능에 관한 연구)

  • Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.417-423
    • /
    • 2020
  • In order to reduce cooling and heating, which is 40% of the energy consumption of buildings, it is important to improve the insulation of the skin. In order to improve the existing insulation, research is being conducted to apply a vacuum insulation panel(VIP) to buildings. However, VIP cannot be repaired, so we considered the metal vacuum insulation panel. Since the core of the metal vacuum pressure and have low thermal conductivity, foam concrete is adopted. However, preliminary experiments confirmed that the time to reach 0.001torr differs depending on the amount and nature of the bubbles. This effect is determined by the type of foaming agent and the density of the bubble slurry, the vacuum delivery time is determined to be the optimum foam concrete conditions are necessary. Therfore, this study aims to present basic data applicable to core materials by measuring vacuum delivery time and thermal conductivity change according to the foaming agent type and foam slurry density of foam large concrete which is core material of metal vacuum insulation panel. Experimental results and analysis show that compressive strength can be used regardless of the type of foam, In terms of thermal conductivity, it is stable to use vegetable foaming agents at 0.9g/㎤ or less. In terms of the vacuum delivery time, the foaming agent appeared similar regardless of the type of foaming agent, but it is considered suitable to use vegetable foaming agent based on compressive strength and thermal conductivity.

Characteristics of Foam Concrete with Application of Mineral Admixture (무기혼화재 적용에 따른 기포콘크리트의 특성)

  • Kim, Sang-Chel;Kim, Yun-Tae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.97-106
    • /
    • 2009
  • self-loading, various problems related to construction can be solved as well as the save of construction cost. Thus, this study has an aim of applying foam concrete to structural purpose by adding bottom ash as a reinforcing material like fine aggregate, in contrast to conventional non-structural usage such as soundproofing or insulating materials. In addition, it was evaluated in terms of unit volume weight, flow value, air void, water absorption and dosage of foam agent wether replacement of cement by granulated blast furnace slag or fly-ash has an effect on the material characteristics of foam concrete. As results of experiments, it can be found that the increase of fine aggregate ratio, that is to say, the increase of bottom ash results in the increase of unit volume weight, while decreasing air void and flow value. But, appropriate addition of bottom ash to foam concrete makes it easy to control a homogeneous and uniform quality in foam concrete due to less sensitive to bubbles. As the replacement ratio of mineral admixtures such as granulated blast furnace slag and fly-ash increases, as unit volume weight tends to decrease. In the meanwhile, serious effects were shown on fluidity of foam concrete when more than limit of replacement ratio was applied.

  • PDF