• 제목/요약/키워드: boiler scale

검색결과 106건 처리시간 0.026초

환경${\cdot}$에너지 시스템에 관한 수치해석적 연구 : SNCR, 보텍스튜브 (Numerical Study on Energy and Environmental System : SNCR, Vortex Tube)

  • 장동순;신나일;서재동;신미수;엄태인;김동찬
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.162-170
    • /
    • 1999
  • Numerical study has been peformed to develop a computer code for the design & optimal operating condition of SNCR(Selective Noncatalytic Reactor) for NOx reduction together with the analysis of the performance of vortex tube. Especially for the SNCR of the scale of industrial boiler, the required mixing and residence time of $NH_3$ solution was successfully tested numerically by the implementation of some baffle setups in a combustor. The introduction of interesting phenomena of vortex tube and similar system is made together with a theoretical hypothesis and simple cold flow simulation for the flow field analysis.

  • PDF

미분탄 연소에 따른 슬래깅 예측 모델 개발 및 검증 (Prediction of ash deposition propensity in a pilot-scaled pulverized coal combustion)

  • 장권우;한가람;허강열;박호영
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.87-90
    • /
    • 2013
  • In pulverized coal fired boilers, slagging and fouling may cause significant effect on the operational life of boiler. As increasing a consumption of low rank coal, slagging and fouling are main issues in pulverized coal combustion. This study predicts ash deposition propensity in a 0.7 MW pilot-scale furnace. Slagging model is employed as a User-Defined Function (UDF) of FLUENT and validated against measurement and prediction. The results show good agreement compared with experiment. There is need to development of a pulverized coal combustion and slagging analysis at low coal.

  • PDF

대용량 보일러의 냉간기동용 액체 연료에 대한 연소 반응성 평가 (Combustion Reactivity Assessments of Oils Used for the Cold Start-Up Operation of Large Scale Boiler)

  • 이장호;박호영
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.77-84
    • /
    • 2022
  • The experimental work has been carried out for the study of pyrolysis of oil samples used in industrial and utility boilers in Korea. For five oil samples, the characteristics of pyrolysis have been investigated with a thermogravimetric analyzer (TGA), and their kinetic parameters were obtained and compared each other. The rate order of pyrolysis rate for five oils were as follows: by-product fuel oil, pyrolysis oil, diesel, a heavy oil and refined oil. The pyrolysis of refined oil has been successfully described by the three step, first order reaction model while the single step reaction model has been used for other oils. For the reaction temperature over 550 K, the reactivity of refined oil was very poor compared with other oils.

순환 유동층 보일러에서 석탄 연소 시 Borax Solution이 연소 배가스중 미세먼지 저감에 미치는 영향 (The Effect of Borax Solution on the Reduction of Fine Particles in Flue Gas at a Commercial Circulating Fluidized-bed Boiler Firing Bituminous Coal)

  • 박재혁;이동호;배달희;최유진;류환우;김지봉;한근희;선도원
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.492-500
    • /
    • 2019
  • 본 연구에서는 $9.2MW_e$의 상용규모 순환유동층 보일러에서 화학첨가제 사용에 따른 미세입자 저감에 대한 영향을 확인하였다. 또한 화력 발전소에서 화석연료의 연소 중 발생하는 미세입자를 포집하기 위하여 간단하고 효과적인 포집설비를 개발하였다. 연소 배가스 중 PM 10이하의 입자를 감소시키기 위하여 화학첨가제를 사용하였으며, 사용한 화학첨가제는 borax solution을 사용하였다. 포집된 미세입자 중 PM 10이하의 입자 거동을 확인하기 위하여 입도분석기와 SEM 분석을 통해 확인하였다. Borax solution은 배가스중에 용융된 미네랄을 흡수하여 미세입자를 성장시키는 경향이 있는 것을 알 수 있었다. 결과적으로 borax solution을 사용함으로써 $10{\mu}m$ 이하의 미세입자가 감소되었음을 확인할 수 있었다.

돼지분뇨 처리를 위한 Farm-scale Two-phase Anaerobic Digester의 실증운영에 관한 연구 (A Study on the Practical Operation of a Farm-scale Two-phase Anaerobic Digester for the Treatment of Swine Manure)

  • 백인규;이상락;안정제;권윤정;맹원재
    • 한국축산시설환경학회지
    • /
    • 제6권2호
    • /
    • pp.73-81
    • /
    • 2000
  • A two-phase anaerobic digestion system for the treatment of swine waste was constructed in a commercial hog farm. The digester system was composed of 4 major units; slurry storage pit, acidogenic digester, methanogenic digester and sedimentation pit. A biogas boiler unit was also attached to maintain the digester temperature of 37$^{\circ}C$. Substrate lading was made with 2hr-interval by pumping about 2.1$m^3$ of slurry type swine waste from the slurry pit into the acidogenic digester, which corresponds to hydraulic retention time of 4 days for the acidogenic digester and of 11 days for the methanogenic digester. Digester temperature were well maintained as the set temperature of 37$^{\circ}C$ in the methanogenic digester, while the temperature in the acidogenic digester showed around 34$^{\circ}C$. pH also showed a steady-state results of 7.3 in the acidogenic digester and of 7.6 in the methanogenic digester during the operation period. Average biogas production rate was 0.66$m^3$/$m^3$ digester volume. Reduction rate of total solid and volatile solid were 42.8% and 5.8%, respectively. Total nitrogen and ammonia nitrogen were not reduced during the anaerobic fermentation, however, most of VFAs seemed to be converted to the biogas,. These fermentation performance data may suggest that he newly developed a two-phase anaerobic digester for the swine waste treatment worked so successfully.

  • PDF

대표적인 열분해가스화 용융시설의 공정별 다이옥신 배출거동에 관한 연구 (A study on the Dioxin behavior in the process of representative pyrolysis/gasfication/melting plant)

  • 신찬기;신대윤
    • 환경위생공학
    • /
    • 제22권1호
    • /
    • pp.1-16
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and is mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasfication/melting process is presented as a alternative of incineration process. The pyrolysis/gasfication/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, it Is investigated that the behavior of dioxins in three pyrolysis/gasfication/melting plant (S, T, P) of pilot scale. In case of S plant, concentration of dioxins shows high at latter part of cogenerated boiler and stack which are operate on low temperature conditions than a latter parts of pyrolysis and melting furnace which are operate on high temperature condition. Concentration of gas phage dioxins had increased after combusted gas passed cogenerated boiler and this is attributed to react of precursor materials such as chlorobenzene and chlorophenol. Concentration of dioxins in T plant showed lower levels at latter part of cooling equipment which are operate with water spray type on low temperature conditions than a latter parts of gasfied melting furnace which are operate on high temperature condition. Removal efficiency of dioxins at gas treatment equipment was 78.8 %. Concentration of dioxins in P plant was low at latter part of SDA/BF which is operate at low temperature conditions than a latter parts of pyrolysis gasfied chamber which are operate at high temperature condition. Removal efficiency of dioxins of SDA/BF was 85.9 % and therefore, it showed high efficiency at those of stoker type incineration facility. However, concentration of dioxins which emitted at high temperature condition were low in three facilities and satisfied present standard emission level of dioxins. To consider the distribution ratio of dioxins, Particulate phase dioxins at S and P plants showed similar ratio with which shows in current stoker type for middle scale domestic waste incineration facility. It is necessary to continuos monitoring the ratio of distribution of dioxins in T plant in because ratio of gas phage dioxins showed high.

노후보일러 유해인자 발굴 및 사고예방에 관한 연구 (A Study on the Identification of Hazardous Factors and Prevention of Accident in Old Boilers)

  • 사민형;우인성
    • 한국가스학회지
    • /
    • 제23권4호
    • /
    • pp.1-9
    • /
    • 2019
  • 큰 규모의 산업용 보일러는 고온, 고압을 이용하는 설비이며, 보유수량이 많아 폭발시 엄청난 에너지가 방출된다. 현재 산업용 보일러는 대부분이 LNG, LPG 등의 가스연료를 사용하고 있고, 연료가 설비와 같은 공간에 존재하기 때문에 보일러 사고 발생시 화재, 폭발 등 2차 피해 가능성이 높다. 뿐만 아니라 단위 사고당 2.51명의 사상자를 발생시키는 대단히 위험한 설비로 운영에 특별한 주의와 관리가 필요하다. 일정 규모 이상의 보일러는 에너지이용 합리화법, KS, 산업통상자원부 고시 등에 따라 한국에너지공단에서 검사를 실시하고 있다. 본 연구에서는 검사 결과 불합격 사항을 바탕으로 위험인자를 구성하고, 검사원, 기기 관리자, 유지보수 담당자, 제조업체 담당자에게 설문을 실시하여 보일러 안전관리에 중요하게 판단하는 기준을 AHP(계층분석방법)을 통해 분석하였다. 분석결과 공통적으로 인식하고 있는 위험인자는 관리소홀, 계측기 고장, 규격미달, 누수, 누설로 분석되었고, 접속, 용접, 스케일, 부식 등은 상대적 중요성이 낮은 것으로 분석되었다. 모든 집단과 경력에서 중요성이 높다고 인식하고 있는 위험인자는 이미 관리가 잘 되고 있다고 판단되나, 중요성이 낮게 분석된 위험인자는 관리누수가 발생되지 않도록하여 보일러를 안전하게 사용할 수 있도록 해야 한다.

중유 연소 시 발생하는 미세입자 및 니켈과 바나듐의 대기 중 배출특성 (Emission Characteristics of Fine Particles, Vanadium and Nickel from Heavy Oil Combustion)

  • 장하나;김성현;이주형;황규원;유종익;석정희;서용칠
    • 한국대기환경학회지
    • /
    • 제22권3호
    • /
    • pp.353-360
    • /
    • 2006
  • This study identified a particle size distribution (PSD) of fine particulate matter and emission characteristics of V and Ni by the comparison between anthropogenic sources of oil combustion (industrial boiler, oil power plant, etc.) and lab-scale combustion using a drop-tube furnace. In oil combustion source, the mass fraction of fine particles (less than 2.5 micrometers in diameter) was higher than that of coarse particles (larger than 2.5 micrometers in diameter) in $PM_{10}$ (less than 10 micrometers in diameter) as like in lab-scale oil combustion. In addition to this, it was identified that ultra-fine particles (less than 0.1 micrometers in diameter) had a large distribution in fine particles. Toxic metals like V and Ni had large mass fractions in fine particles, and most of all was distributed in ultra-fine particles. Most of ultra-fine particles containing toxic metals have been emitted into ambient by combustion source because it is hard to control by the existing air pollution control device. Hence, we must be careful on these pollutants because it is obvious that these are associated with adverse health and environmental effect.

고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향 (Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique)

  • 조승연;김태희;장인성;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

연소가스내 탈황탈질처리를 위한 저온 플라즈마 기술 (Non-Thermal Plasma Technique for Removing $SO_2$ and $NO_x$ from Combustion Flue Gas)

  • 송영훈;신완호;김석준;장길홍
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.69-76
    • /
    • 1997
  • Industrial-scale pulse corona process to remove $SO_2$ and $NO_x$ simultaneously from combustion flue gas has been studied. The pilot plant built in the present study treats 2,000 $Nm^3$/hr of flue gas from a boiler. The geometry of the pulse corona reactor is similar to that of an electrostatic precipitator commonly used in industry, A thyratron switch and magnetic pulse compressors, which can generate up to 130 kV of peak pulse voltage and up to 30 kW of average pulse power, have been used to produce pulsed corona. The removal efficiencies of $S0_2$ and $NO_x$ with the present process are maximum of 95 % and 85 %, respectively. Electrical power consumption to produce the pulsed corona, which has been one of the major difficulties to apply this process to industry, has been evaluated in the present study. The results showed that the power consumption can be reduced significantly by simultaneous addition of hydrocarbon injection and heterogeneous phase reactions to the process.

  • PDF