Conductive Rubber for Enhanced Safety in Hydrogen-based Facilities from Electrostatic Discharge (도전성 고무 매트를 이용한 수소 기반 시설에서 제전 신뢰성 향상)

  • S. Lee;J. Ko;J. Song;C. Kim;C. Kim;H. S. Kim;M. E. Hur;Chung J. H.;H. J. Song
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.9-15
    • /
    • 2024
  • Hydrogen-based electricity and transportation systems are widely recognized as sustainable power sources. However, the low ignition energy of hydrogen, only 1/10th that of conventional fossil fuels, poses a safety concern involving the risk of ignition due to electrostatic discharge from facility workers. Therefore, anti-static systems are imperative for hydrogen-based electricity facilities. To address this, we propose a reliable conductive rubber mat (CRM) to ensure the safety of these facilities. Unlike conventional anti-static floors that utilize conductive paint (CP), the CRM features a uniform distribution of conductive components in chemically and mechanically stable rubber. As a result, the CRM is unyielding to polar solvents (such as ethanol and hydrosulfuric acid) and non-polar solvents (like mineral oil) without increasing its resistance. Moreover, the CRM can withstand mechanical stress. Consequently, the human-body voltage of workers on the CRM would be sufficiently low enough to protect them from hydrogen explosions, thereby enhancing overall safety.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Switching and Leakage-Power Suppressed SRAM for Leakage-Dominant Deep-Submicron CMOS Technologies (초미세 CMOS 공정에서의 스위칭 및 누설전력 억제 SRAM 설계)

  • Choi Hoon-Dae;Min Kyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.21-32
    • /
    • 2006
  • A new SRAM circuit with row-by-row activation and low-swing write schemes is proposed to reduce switching power of active cells as well as leakage one of sleep cells in this paper. By driving source line of sleep cells by $V_{SSH}$ which is higher than $V_{SS}$, the leakage current can be reduced to 1/100 due to the cooperation of the reverse body-bias. Drain Induced Barrier Lowering (DIBL), and negative $V_{GS}$ effects. Moreover, the bit line leakage which may introduce a fault during the read operation can be eliminated in this new SRAM. Swing voltage on highly capacitive bit lines is reduced to $V_{DD}-to-V_{SSH}$ from the conventional $V_{DD}-to-V_{SS}$ during the write operation, greatly saving the bit line switching power. Combining the row-by-row activation scheme with the low-swing write does not require the additional area penalty. By the SPICE simulation with the Berkeley Predictive Technology Modes, 93% of leakage power and 43% of switching one are estimated to be saved in future leakage-dominant 70-un process. A test chip has been fabricated using $0.35-{\mu}m$ CMOS process to verify the effectiveness and feasibility of the new SRAM, where the switching power is measured to be 30% less than the conventional SRAM when the I/O bit width is only 8. The stored data is confirmed to be retained without loss until the retention voltage is reduced to 1.1V which is mainly due to the metal shield. The switching power will be expected to be more significant with increasing the I/O bit width.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs) (산란선 대 일차선비(SPR)를 이용한 MV 영상의 산란 보정을 위한 실험적 방법)

  • Jeon, Hosang;Park, Dahl;Lee, Jayeong;Nam, Jiho;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye;Kim, Dongwon
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.143-150
    • /
    • 2014
  • In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.

The Usefulness of Bone Scan in Electric Burns (전기화상에서 골스캔의 유용성)

  • Kim, Tae-Hyung;So, Yong-Seon;Kweon, Ki-Hyeon;Han, Sang-Woong;Kim, Seok-Hwan;Kim, Jong-Soon;Han, Seung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.130-138
    • /
    • 1996
  • Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as deforming to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites & bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication. There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, serum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  • PDF

An Experimental Study on Ground Resistivity and Grounding Resistance of Water Environment (수상환경의 대지저항률 및 접지저항 측정의 실험적 연구)

  • Choi, Young-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2343-2348
    • /
    • 2014
  • Main ground net of power plant is formed to protect human body from increase in potential gradient caused by grounding current during ground fault. Calculations during ground design are generally performed according to IEEE Std-80-2000 (Kepco Design Standard 2602). However, it is difficult to apply this Standard to water environment, and a grounding technology is required to secure grounding resistance of floating photovoltaic system. Therefore the aim of this paper is to investigate and analyze ground resistivity on the water surface and underwater of reservoir using Wenner 4-pin method, a general method of measuring ground resistivity. Also, grounding resistance of floating photovoltaic systems currently in operation was measured and analyzed using the voltage drop method suggested in the international standard (IEEE Std-81) to propose a grounding method for stable grounding of floating photovoltaic system. The resistivity at 1m below the surface of water ($126.3969[{\Omega}{\cdot}m]$) is mostly higher than resistivity at the river bed ($97.5713[{\Omega}{\cdot}m]$). Also the proposed grounding anchor method was determined as the most effective method of securing stable grounding resistance in floating photovoltaic systems and is expected to be utilized as a ground method for future floating photovoltaic generation systems.

Development of Portable-Type Electrode for the Determination of Highly Concentrated Hydrogen Peroxide (휴대용 고농도 과산화수소 측정 전극의 개발)

  • Lee, Jin Seo;Cui, Gang;Kim, Sang Jin;Cha, Geun Sig;Nam, Hakhyun;Rho, Kyung Lae;Kim, Jin Doo
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.125-129
    • /
    • 1999
  • Portable-type two electrode system for the determination of highly concentrated hydrogen peroxide (10-75%) has been studied. The electrode body was made with teflon rod (length=10 cm, diameter=1.5 cm) to withstand the highly corrosive power of hydrogen peroxide. Glass carbon rod (diameter=3 mm) was used as the working electrode and a carbon cylinder (i.d.=5 mm; o.d.=9 mm) was used as counter electrode. The applied voltage for the determination of $H_2O_2$ was 0.8 V. Diluting the highly concentrated samples taken from the industrial batch to 10% or less, it was possible to make quantitative determinations, while eliminating the interference from the stabilizer contained in the sample and preventing the surface of the electrode from oxidative corrosion. Employing hydrogen peroxide permeable membrane (teflon membrane${\leq}100{\mu}m$) for the electrode system, it was possible to measure the content of $H_2O_2$ in highly concentrated samples directly, quantitatively and reproducibly with no extra dilution step. However, it was necessary to change the internal electrolyte frequently to maintain the analytical performance of the electrode.

  • PDF

Morphology of RF-sputtered Mn-Coatings for Ti-29Nb-xHf Alloys after Micro-Pore Form by PEO

  • Park, Min-Gyu;Park, Seon-Yeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.197-197
    • /
    • 2016
  • Commercially pure titanium (CP Ti) and Ti-6Al-4V alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Manganese(Mn) plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Radio frequency(RF) magnetron sputtering in the various PVD methods has high deposition rates, high-purity films, extremely high adhesion of films, and excellent uniform layers for depositing a wide range of materials, including metals, alloys and ceramics like a hydroxyapatite. The aim of this study is to research the Mn coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. Mn coatings was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Mn coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF