• Title/Summary/Keyword: body position

Search Result 1,474, Processing Time 0.026 seconds

Vibration Analysis of a Pulsator type Washing System (펄세이터형 세탁 시스템의 진동 해석)

  • 이신영;강주석;윤중락;이장무;윤구영;김남권
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.261-272
    • /
    • 1997
  • Recently washing machines are to be in lower vibration and lower sound because of better environment. Vibration problems in washing machines occur in both washing mode and spinning mode, but vibration in spinning mode becomes main problem because of its high rotating speed and continuity. Vibration while spinning is mainly due to rigid body motion of total washing system which includes suspending rods, washing bath, spinning bath, and gear sets. In this study, some researches were done in order to analyze the rigid body motion of washing system and flexible vibration of spinning bath. A basic mathematical model was established, and the effect of position of salt water and shape change of salt water case were considered. And the effect of lengths of suspending rods, attaching angles, vertical and horizontal position, stiffness of spring on the change of vibration were also considered. To identify the effect of salt water on vibration, some measurements were done. When salt water was positioned at upper part, the effect was most and this coincides with the tendency of simulation.

  • PDF

Hull form design for resistance minimization of small-scale LNG bunkering vessels using numerical simulation

  • Pak, Kyung-Ryeong;Song, Gi-Su;Kim, Hee-Jung;Son, Hye-Jong;Park, Hyoung-Gil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.856-867
    • /
    • 2020
  • This paper aims to provide the most useful method of determining an optimum LCB position and design direction of fore- and aft-body hull shape for a SLBV. It is known that the SLBV has a lower length-to-beam ratio, larger Cb and simpler stern shape designed for the installation of azimuth thrusters comparing to those of conventional LNG carriers. Due to these specific particulars of SLBV, the optimum LCB position was very different to that of conventional LNG carrier. And various approaches were applied to determine the optimum fore- and aft-body hull shape. The design direction for the optimum hull-form was evaluated as the minimization of the total resistance which includes the wave-making resistance and form-drag with numerical simulation.

The Factor of Knee Joint Function in Women (여성의 무릎관절 기능 영향요인)

  • Lee, Hyun-Ok;Yang, Kyung-Hye
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.67-75
    • /
    • 2010
  • Purpose: The purpose of this is to identify the relationship among the age, body mass index(BMI) and exercise frequency(EF) with knee joint position sense in korean healthy women. Methods: Healthy women of 328 who participated in this study were tested knee joint position sense; reposition error was measured with a Myrin goniometer. Each reposition error was analyzed using descriptive statics, pearson correlation coefficients, and stepwise multiple regression. Results: The mean reposition error by age groups was significant decrease getting older. The mean reposition error by BMI groups was significant decrease getting higher. And the mean reposition error by EF groups was significant decrease getting lower. The knee joint position sense showed a significantly correlation with age(r=0.36, p=.00), BMI(r=0.34, p=.00) and EF(r=-0.50, p=.00). The most powerful predictor of knee joint position sense was EF. The reposition error according to stepwise multiple regression is $3.36+(-2.64){\times}EF+0.13{\times}age$, and account for 46%($R^2=0.46$) of the variance in the knee joint position sense. Conclusion: The older the women are, for prevent of knee injuries due to decreased joint position sense, regular exercise is essential factor.

  • PDF

Effects of the Trunk Maintenance Repositioning Method on Keeping a 30° Side-Lying Position, Comfort, and Skin Condition (체간 유지 체위변경 방법이 30도 측위 유지, 편안함 및 피부 상태에 미치는 효과)

  • Lee, Chae Won;Yi, Young Hee
    • Journal of Korean Critical Care Nursing
    • /
    • v.11 no.1
    • /
    • pp.79-88
    • /
    • 2018
  • Purpose : This study was performed to evaluate the effects of a prolonged a $30^{\circ}$ side-lying position on comfort and skin condition by applying the trunk maintenance repositioning method, which can keep the $30^{\circ}$ side-lying position effective for preventing pressure ulcers. Method : Fifty-four healthy nurses working at a general hospital in Seoul were randomly assigned to an experimental group (n=27) or a control group (n=27) and assumed a position of lying on their right or left side for two hours. The trunk maintenance repositioning method was applied to the experimental group using the pillow made by the researcher, while the original repositioning method was applied to the control group using the regular pillow from the subject hospital. Participants' posture angles, comfort, and skin condition were measured at the time of the intervention, as well as at one and two hours after the intervention. Results : There was no statistically significant difference in position angle, comfort, skin condition change, or sacrum and greater trochanter pressure change between the two groups over time. Conclusion : It is necessary to review the method and frequency of change of position in each hospital. In addition, a proper position changing pillow should be developed in consideration of patients' various body shapes.

The Effect of Body Mass Index on Intra-Abdominal Pressure and Blood Loss in Lumbar Spine Surgery

  • Han, In-Ho;Son, Dong-Wuk;Nam, Kyoung-Hyup;Choi, Byung-Kwan;Song, Geun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.2
    • /
    • pp.81-85
    • /
    • 2012
  • Objective : The purpose of this prospective study was to evaluate the effects of body mass index (BMI) on intra-abdominal pressure (IAP) and intraoperative blood loss (IBL) during lumbar spinal surgery. Methods : Thirty patients scheduled for single level posterior lumbar interbody fusion were allocated equally to a normal group (Group 1, BMI;$18.5-22.9kg/m^2$), an overweight group (Group 2, BMI; $23-24.9kg/m^2$), and an obese group (Group 3, BMI; $25.0-29.9kg/m^2$) according to BMI. IAP was measured using a urinary bladder catheter; 1) supine after anesthesia induction, 2) prone at skin incision, 3) prone at the end of surgery. In addition, IBL was also measured in the three groups. Results : IAP in the supine position was not significantly different in groups 1, 2, and 3 (2.7 mm Hg, 3.0 mm Hg, and 4.2 mm Hg, respectively) ($p$=0.258), and IAP in the prone position at incision increased to 7.8 mm Hg, 8.2 mm Hg, and 10.4 mm Hg, respectively, in the three groups, and these intergroup differences were significant, especially for Group 3 ($p$=0.000). IAP at the end of surgery was slightly lower (7.0 mm Hg, 7.7 mm Hg, and 9.2 mm Hg, respectively). IBLs were not significantly different between the three groups. However, IBLs were found to increase with IAP in the prone position ($p$=0.022) and BMI ($p$<0.05). Conclusion : These results show that BMI affects IAP in the prone position more than in the supine position during lumbar spinal surgery. In addition, IBLs were found to increase with IAP in the prone position and with BMI. Thus, IBLs can be expected to be higher in morbidly obese patients due to an increased IAP.

Effects of an Inverted Position on EEG and Heart Rate Variability before and after Qi-gong Training (어깨지지형 도립위(倒立位)가 기공수련(氣功修鍊) 전후(前後)의 뇌파(腦波) 및 심박변이도(心搏變移度)에 미치는 영향)

  • Lee, Sang-Nam;Kwon, Young-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.918-929
    • /
    • 2008
  • This study investigated the effects of inverted position on EEG and heart rate variability before and after Bang song gong. BSG is a training method using in qi-gong and meditation to give a convergence of consciousness on body segments in order and take a silent speech of 'song'. The subjects were the 14 university students(n=7 per group) who had not experienced any medical problem and had not practiced BSG. They took a practice of the two way of BSG training program for 30 minutes every other day for two weeks. During practicing BSG, A group took sitting position and lean sitting position by turns, B group took inverted and lean sitting position in the same way. Statistical analysis conducted by two-way ANOVA($2groups^{\ast}2periods$) with p<0.05 for average difference of EEG and HR according to position change in each group before and after BSG. In A group, EEG and HR were changeless irrespective of the change of position and BSG. On the other hand, in B group, significant changes were observed in EEG(p<0.05). ${\alpha}$ wave of inverted position were on the increase, ${\beta}$ and ${\delta}$ wave of inverted position showed smaller power after two weeks training. In the variation of HR, there were smaller variation according to the position change after BSG compared to before BSG(p<0.05). The results suggested that an inverted position may make the depth of meditation deeper, and is likely to be effective for decreasing tension of brain and the sleepiness during qi-gong training. In addition to, an inverted position seemed to promote control of blood pressure of brain. So the application of an inverted position to 'BSG' will be very helpful to achieve deeper relaxation and to obtain the desired effect from qi-gong training.

CT Simulation Technique for Craniospinal Irradiation in Supine Position (전산화단층촬영모의치료장치를 이용한 배와위 두개척수 방사선치료 계획)

  • Lee, Suk;Kim, Yong-Bae;Kwon, Soo-Il;Chu, Sung-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • Purpose : In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. Materials and Method : A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetrie image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was peformed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. Results : CSI in the supine position was successfully peformed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The differences between the DRRs and the portal films were less than 3 mm in the vertebral contour. Conclusion : CSI in the supine position is feasible in patients who cannot lie on prone position, such as pediatric patienta under the age of 4 years, patients with a poor general condition, or patients with a tracheostomy.

Assessment of Counting Efficiency of a Whole Body Counter by Human Body Size and Standing Position Using Monte Carlo Method (몬테카를로 방법론을 이용한 측정 대상의 인체 크기와 측정 위치에 따른 전신계수기 계수효율 평가)

  • Pak, Min Jung;Yoo, Jae Ryong;Ha, Wi-Ho;Lee, Seung-Sook;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.46-53
    • /
    • 2014
  • For the case of radiation emergency, it is required to assess internal contamination of the public, including children as well as adults. The objective of the present study was to assess counting efficiency of a whole body counter by human body size and standing position of the measurement person. In this study, the FASTSCAN whole body counter used at National Radiation Emergency Medical Center of Korean Institute of Radiological and Medical Science was simulated by a radiation transport computer code. The simulation results of the counting efficiencies agreed well with measurements within the 2% of discrepancy for 4-year child and 5% for adults. The standing positions of the people were adjusted by body size to find the consistent trend of the counting efficiencies by human body size. Body size scaling factors of the whole body counter were derived to consider human body size and improve the measurement accuracy. The counting efficiency assessment methodology in this study can be successively used to improve the measurement accuracy when using a whole body counter for the case of radiation emergency.

Device for Catheter Placement of External Ventricular Drain

  • Ann, Jae-Min;Bae, Hack-Gun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.322-324
    • /
    • 2016
  • To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.

Position Detection Algorithms Using 3-Axial Accelerometer Sensor (3축 가속도 센서를 이용한 위치 검출 알고리즘)

  • Kim, Nam-Jin;Choi, Young-Hee;Choi, Lee-Kwon
    • Journal of Information Technology Services
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2011
  • In this paper, we consist of three dimensional acceleration sensor as a small-sized sensor module to acquire base technologies that need to estimate exhibition audience' moving distance. and that we developed algorism and device that can calculate acceleration in gravity direction with attaching it to people's body part without regard to three dimensional direction. By making use of the sensor module, we have to process the data that let it quantitatively process possible to measure people's walk and movement by computer system. We normalized sensor output data in the process of change from sensor module to acquisition of data, rectangular coordinates and single scalar acceleration value in gravity direction. Printed out sensor data attaching sensor module to people's body part is used for motion pattern detection after normalization, Motion sensor devised mode change algorism because it print data of other pattern according to attached position of body. For algorism design, we collected data occurring during walking about subject and we also defined occurring problem domain after analyzing the data. We settle defined problem domain and that we simulated the walking number measuring instrument with highly efficient in restricted environment.