• 제목/요약/키워드: biomedical metal

검색결과 183건 처리시간 0.025초

유한요소법을 이용한 비귀금속-도재관 변연부 형태에 따른 응력 분포 분석 (Finite Element Analysis on Stress Distribution in Base Metal-Ceramic Crown Margin Designs)

  • 이명곤;신정욱;김명덕
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.79-88
    • /
    • 2000
  • The objective of this finite element method study was to analyze the stress distribution induced in a maxillary central incisor Ni-Cr base metal coping ceramic crowns with various margin design. Margin designs of crown in this experiment were knife-edge metal margin on chamfer finishing line of tooth preparation(M1), butt metal margin on shoulder finishing line(M2), reinforced butt metal margin on shoulder finishing line(M3), beveled metal margin on bevelde shoulder finishing line(M4). Two- dimensional finite element models of crown designs were subjected to a simulated biting force of 100N which was forced over porcelain near the lingual incisal edge. Base on plane stress analysis, the maxium von Miss stresses(Mpa) in porcelain venner was 0.432, in metal coping was 0.579, in dentin abutment was 0.324 for M1 model, and M2 model revealed in porcelain was 0.556, in metal coping was 0.511, in dentin was 0.339, and M3 model revealed in porcelain was 0.556, in metal coping was 0.794, in dentin was 0.383 for M4 model. All values of each material in metal-ceramic crown were much below the critical failure values.

  • PDF

Direct Metal Laser Sintering-New Possibilities in Biomedical Part Manufacturing

  • Kotila, Juha;Syvanen, Tatu;Hanninen, Jouni;Latikka, Maria;Nyrhila, Olli
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.248-249
    • /
    • 2006
  • Direct Metal Laser Sintering (DMLS) has been utilized for prototype manufacturing of functional metal components for years now. During this period the surface quality, mechanical properties, detail resolution and easiness of the process have been improved to the level suitable for direct production of complex metallic components for various applications. The paper will present the latest DMLS technology utilizing EOSINT M270 laser sintering machine and EOSTYLE support generation software for direct and rapid production of complex shaped metallic components for various purposes. The focus of the presentation will be in rapid manufacturing of customized biomedical implants and surgical devices of the latest stainless steel, titanium and cobalt-chromium-molybdenum alloys. In addition to biomedical applications, other application areas where complex metallic parts with stringent requirements are being needed will be presented.

  • PDF

PDMS 기판상에 금속층의 안정적 증착 및 패터닝 (The stable e-beam deposition of metal layer and patterning on the PDMS substrate)

  • 백주열;권구한;이상훈
    • 센서학회지
    • /
    • 제14권6호
    • /
    • pp.423-429
    • /
    • 2005
  • In this paper, we proposed the fabrication process of the stable e-beam evaporation and the patterning of metals layer on the polydimethylsiloxane (PDMS) substrate. The metal layer was deposited under the various deposition rate, and its effect to the electrical and mechanical properties (e.g.: adhesion-strength of metal layer) was investigated. The influence of surface roughness to the adhesion-strength was also examined via the tape test. Here, we varied the roughness by changing the reactive ion etching (RIE) duration. The electrode patterning was performed through the conventional photolithography and chemical etching process after e-beam deposition of $200{\AA}$ Ti and $1000{\AA}$ Au. As a result, the adhesion strength of metal layer on the PDMS surface was greatly improved by the oxygen plasma treatment. The e-beam evaporation on the PDMS surface is known to create the wavy topography. Here, we found that such wavy patterns do not effect to the electrical and mechanical properties. In conclusion, the metal patterns with minimum $20{\mu}m$ line width was produced well via the our fabrication process, and its electrical conductance was almost similar to the that of metal patterns on the silicon or glass substrates.

초내식성 스테인레스강의 금속이온용출특성 및 세포적합성 (Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel)

  • 김철생;박진수;허억;강곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF

도재-금속의 결합 강도에 미치는 비금속 합금의 열처리 효과 (The effect of preheat treatment on ceramic to metal bond strength)

  • 김치영;김영곤;조현설
    • 대한치과기공학회지
    • /
    • 제24권1호
    • /
    • pp.33-41
    • /
    • 2002
  • In dental prosthetics, the application of metal-ceramic restorations has steadily increased since their introduction. This is due to excellent esthetics in combination with high mechanical stability. In order to optimum bond strength between metal and ceramics, controlled oxidation of metal substructure is essential factor. Beryllium containing and beryllium free Ni-Cr alloys for metal-ceramic restorations were evaluated for the metal-ceramic bond strength by changing heat treatment for oxide formation. A mechanical three-point bending test was employed to evaluate the interfacial bond strength of metal-ceramic. In each metal, plate type specimens were used for mechanical three-point bending test. With Ni-Cr alloys for metal ceramics, mechanical three-point bending test showed that double degassing was more available preheat treatment method than another. It was found that beryllium containing Ni-Cr alloys are more effective than beryllium-free for metal-ceramic bond strength.

  • PDF

Image Denoising for Metal MRI Exploiting Sparsity and Low Rank Priors

  • Choi, Sangcheon;Park, Jun-Sik;Kim, Hahnsung;Park, Jaeseok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.215-223
    • /
    • 2016
  • Purpose: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called "Slice Encoding for Metal Artifact Correction (SEMAC)" is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. Materials and Methods: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, $l_1$ minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. Results: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. Conclusion: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.

Coating defects in polymer-coated drug-eluting stents

  • Bedair, Tarek M.;Cho, Youngjin;Park, Bang Ju;Joung, Yoon Ki;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권3호
    • /
    • pp.131-150
    • /
    • 2014
  • Vascular stenting has a great attention as a treatment for coronary arteries diseases as compared with percutaneous balloon angioplasty. In-stent restenosis and thrombosis are side effects resulting from using bare metal stent (BMS). Employing platelet therapy allowed to reduce the rate of thrombosis, however, the rate of restenosis remains a major problem. In 2002, drug-eluting stents (DESs) were introduced as an effort to reduce the restenosis. The commercially available DESs continue to suffer from coating defects that might lead to a series of adverse effects. Most importantly, multiple concerns remain regarding the polymer coating integrity on metal surfaces or the relation of polymer irregularities to longterm adverse events.

전기분사를 이용한 의료용 금속 임플란트의 생분해성 PLGA 고분자 코팅 (Biodegradable PLGA Polymer Coating on Biomedical Metal Implants Using Electrospraying)

  • 조성배;박철호;박귀덕;정동준;한동근
    • 폴리머
    • /
    • 제33권6호
    • /
    • pp.620-624
    • /
    • 2009
  • 의료용 금속 임플란트는 우수한 기계적 강도를 바탕으로 결손된 신체 부위의 보강, 대치, 회복을 위해 임상적으로 사용되고 있지만, 낮은 생체적합성 및 독성 때문에 염증 및 후기 혈전증, 재협착의 문제점을 가지고 있다. 이런 단점을 보안하기 위한 다양한 표면처리 기술 중, 본 연구에서는 금속표면에 생분해성 고분자인 poly (lactic-co-glycolic acid) (PLGA)를 이용하여 전기분사 코팅(electrospray coating) 기술을 검토하였다. 전기분사와 용액 인자들의 기초적인 조사를 바탕으로, 코팅 필름의 표면형상은 방울이 날아가는 거리, 용매의 비등점, 방울의 크기에 밀접한 관련이 있다. 고분자 필름의 두께는 분사량에 선형적으로 비례를 하였다. 이 결과는 전기분사된 고분자 방울이 계속적으로 고분자 필름 위에 적층되는 것을 보여준다. 따라서, 전기분사 코팅기술은 스텐트와 같은 의료용 금속 임플란트에 있어서 표면 형상 조절, 나노/마이크로 두께의 단/다중층의 고분자 필름을 제조하는데 적용될 수 있다.

Comparison of Heavy Metal Level in Blood Between Industrial Workers and General People

  • Lee Mi-Hwa
    • 대한의생명과학회지
    • /
    • 제10권4호
    • /
    • pp.453-457
    • /
    • 2004
  • The welders and car painters are frequently exposed to heavy metals such as lead, zinc, cadmium and chromium, and those are a major source of heavy metal poisoning. This study was carried out to investigate the relationship of the heavy metal level in blood by age, working duration, and smoking status among 105 industrial workers and 88 general people in Gyeongnam province from October 2003 to October 2004. The heavy metal level in blood was analyzed by atomic absorption spectrophotometer. Mean blood lead level in exposed group and control group was 8.40±4.67μl/dl, 1.82±1.35μl/dl, respectively. Mean blood zinc level in exposed group and control group was 9.43±5.38 ㎍/ml, 2.89±1.79㎍/ml, respectively. Mean blood cadmium level in Exposed group and control group was 1.53±1.05μl/dl, 0.60±0.49 μl/dl, respectively. Mean blood chromium level in exposed group and control group was 0.89±0.76μl/dl, 0.68±0.63μl/dl, respectively. Lead, zinc, cadmium and chromium level in blood of exposed group was significantly higher than that of control group. In the comparison of smoking status, lead, zinc and cadmium level of smoker's was significantly higher than that of non-smoker's. Comparison of heavy metal level by age, lead, zinc, cadmium level in 40's, 50's (exposed group) in blood significantly higher than that of 20's, 30's. In exposed group, working duration has no significant difference. In conclusion, smoking was the most hazardous factor to elevate in blood heavy metal levels.

  • PDF

Characterization of Thickness and Electrical Properties of Ni-Cr Thin Films via Terahertz Time-domain Spectroscopy

  • Sunghun Kim;Inhee Maeng;Hyeon Sang Bark;Jungsup Byun;Jae Hun, Na;Seho Kim;Myeong Suk Yim;Byung-Youl Cha;Youngbin Ji;Seung Jae Oh
    • Current Optics and Photonics
    • /
    • 제7권5호
    • /
    • pp.569-573
    • /
    • 2023
  • We utilized terahertz time-domain spectroscopy (THz-TDS) to measure the thickness and electrical properties of nickel-chromium (Ni-Cr) films. This technique not only aligns well with traditional methods, such as haze-meter and transmission-densitometer measurements, but it also reveals the electrical properties and thickness of films down to a few tens of nanometers. The complex conductivity of the Ni-Cr thin films was extracted using the Tinkham formula. The experimental values closely aligned with the Drude model, indicating the reliability of our Ni-Cr film's electrical and optical constants. The thickness of Ni-Cr was estimated using the complex conductivity. These findings emphasize the potential of THz-TDS in quality control of metallic nanofilms, pointing toward an efficient and nondestructive test (NDT) for such analyses.