• 제목/요약/키워드: atmospheric $CO_2$ concentration

검색결과 326건 처리시간 0.03초

EUREKA E!3266 (EUROENVIRON WEBAIR SYSTEM)에 의한 대기질 모델링 시스템 (AIRWARE) 개발 (Development of AIRWARE System by EUREKA E!3266-EUROENVIRON WEBAIR SYSTEM)

  • 이헌창;정재칠;;김동영;김태진
    • 한국대기환경학회지
    • /
    • 제25권2호
    • /
    • pp.167-174
    • /
    • 2009
  • The AIRWARE System was developed from one of the EUREKA PROJECT E!3266-EUROENVIRON WEBAIR System. The AIRWARE can nowcast and forecast the air quality of Seoul and Gyeonggi-do regions. To nowcast and forecast concentration of pollutants, MM5, AERMOD/CAMx, and SMOKE Models were used for each meteorologic data, measured data, and emission data. All DB were constructed for 2001 year. The episode analysis and time series analysis were accomplished to analyze the AIRWARE reliability. The simulated results were very well agreed with measured result for measured pollutants and meteorological data. The developed AIRWARE system can analyze with real-time, support web-based air quality information. This information can used with policy data to manage the air quality and prepare reduction plan in air impact assessment or air environmental plan.

다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용 (Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System)

  • 유재일;이동호;홍진규;김준
    • 한국농림기상학회지
    • /
    • 제11권1호
    • /
    • pp.27-38
    • /
    • 2009
  • 연직으로 여러 높이에서 측정된 기체의 농도는 다양한 목적에 활용될 수 있다. 예를 들어, 복잡지형에 위치한 우리나라의 일반적인 산림유역에서 에디공분산방법에 의한 증발산 및 이산화탄소 순생태 교환량(Net Ecosystem Exchange, NEE)을 관측하기 위해서는 수평 및 연직 이류(advection)와 저류(storage)항의 효과를 정량화해야 한다. 그리고 미량 기체의 발원 및 흡원을 추적하거나 관측의 발자국 분석을 위해서도 필요하다. 수증기와 이산화탄소의 연직 농도 분포는 일반적으로 에디공분산 플럭스 타워에 보조 장치로 설치되는 다중 기체 프로파일 관측시스템(이하 프로파일 시스템)에 의해 측정된다. 이 시스템은 다른 미기상 관측기기와는 달리 서로 독립된 여러 기기와 장치들이 하나의 목적을 위해 결합되어 작동되기 때문에 사용방법과 기기의 운영/유지/보수에 많은 어려움이 따른다. 현재 전세계적으로 플럭스 타워 관측과 함께 이용되고 있는 프로파일 시스템은 대부분 미국의 캠벨사(Campbell Sci. Inc.)에서 제작/판매하는 시스템과 개별 연구자들이 각자의 목적과 관측환경에 적합하도록 자체 제작한 시스템으로 구분된다. 연세대학교 대기과학과 생물기상/생지화학 연구팀은 2005년부터 광릉 산림유역의 활엽수림과 침엽수림에 미국 캠벨사에서 제작한 두 개의 프로파일 시스템을 설치/운영하며 다양한 기술적, 이론적 경험과 지식을 축적해 왔다. 이 총설에서는 복잡지형 산림에서의 물과 탄소의 순생태 교환량 관측에 중요한 도구로 사용되는 프로파일 시스템의 원리, 구성, 활용 방법에 대해서 소개한다.

철강 산업의 산업공정부문 CO2 실측 배출계수 산정에 관한 연구 (An Estimation of Plant Specific Emission Factors for CO2 in Iron and Steel Industry)

  • 엄윤성;홍지형;김정수;김대곤;이수빈;송형도;이성호
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.50-63
    • /
    • 2007
  • The development of domestic plant specific emission factors is very important to estimate reliable national emissions management. This study, for the reason, was carried out to obtain advances emission factor for Carbon Dioxide ($CO_2$) by source-specific emission tests from the iron and steel industry sector which is well known as one of the major sources of greenhouse gases ($CO_2$). Emission factors estimated in this study were compared with those of IPCC for evaluation and they were found to be of similar level in the case of $CO_2$. There was no good information available on $CO_2$ plant specific emission factors from the iron and steel industry in Korea so far. The major emission sources of $CO_2$ examined from the iron and steel manufacturing precesses were a hot blast stove, coke oven, sintering furnace, electric arc furnace, heating furnace, and so on. In this study, the concentration of $CO_2$ from the hot blast stove process was the highest among all processes. The $CO_2$ emission factors for a ton of Steel and Iron products (using B-C oil) were estimated to be 0.315 $CO_2$ tonne (by Tier 3 method) and 4.89 $CO_2$ tonne. In addition, emission factor of $CO_2$ for heating furnace process was the highest among all process. Emission factors estimated in this study were compared with those of IPCC for evaluation and they were found to be of similar level in the case of $CO_2$.

제올라이트 5A와 13X의 저농도 이산화탄소 흡착 및 탈착특성 (Adsorption and Desorption Characteristics of Carbon Dioxide at Low Concentration on Zeolite 5A and 13X)

  • 조영민;이지윤;권순박;박덕신;최진식;이주열
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.191-200
    • /
    • 2011
  • A way to adsorptively remove indoor carbon dioxide at relatively lower concentration under ambient temperature was studied. A small lab-scale carbon dioxide adsorption and desorption reactors were prepared, and 5A and 13X zeolites were packed in this reactors to investigate their adsorption and desorption characteristics. The inflow carbon dioxide concentration was controlled to 5,000 ppm, relatively higher concentration found in indoor spaces with air quality problems, by diluting carbon dioxide with nitrogen gas. The flow rate was varied as 1~5 L/min, and the carbon dioxide concentration after this reactor was constantly monitored to examine the adsorption characteristics. It was found that 5A adsorbed more carbon dioxide than 13X. A lab-scale carbon dioxide desorption reactor was also prepared to investigate the desorption characteristics of zeolites, which is essential for the regeneration of used zeolites. The desorption temperature was varied as $25{\sim}200^{\circ}C$, and the desorption pressure was varied as 0.1~1.0 bar. Carbon dioxide desorbed better at higher temperature, and lower pressure. 5A could be regenerated more than three times by thermal desorption at $180^{\circ}C$. It is required to modify zeolites for higher adsorption and better regeneration performances.

2행정 소형엔진의 대기오염물질 배출특성에 관한 연구 (A Study on the Characteristic of Emission for Air Pollutant by Small Two-stroke Engines)

  • 김필수;최상진;박건진;한용희;김대곤;여소영;김정;고지원;장영기
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.613-623
    • /
    • 2016
  • In this study, pilot experiments were conducted by setting operation conditions to analyze characteristics of emission for air pollutant from small two-stroke engines. Emission factors of the measured concentration of pollutant were compared with EEA. Emission factor of CO analyzed by experiments - concentration, flow rate, fuel consumption, etc.- was estimated at 816,011 g-CO/ton-fuel in average. It was confirmed that more than 80% of the fuel consumption is discharged to the Carbon Monoxide, and that as the engine load becomes higher, emission factor of CO increases in the form of log function. The average emission factor of $NO_x$ and $PM_{10}$ was $3,801g-NO_x/ton-fuel$ and $3,730g-PM_{10}/ton-fue$l each. The deviation was not large by comparing the fuel-based emission factor of EEA and the result of this study. Since considerable pollutants are expected to be discharged from the small two-stroke engines, continuous research and support of the policy is required.

대기 중 이산화질소의 단기 측정을 위한 뱃지형 passive sampler의 개발 및 평가 (Development and Evaluation of a Badge-type Passive Sampler for the Measurement of Short-term Nitrogen Dioxide in Ambient Air)

  • 김선규;임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제22권1호
    • /
    • pp.117-126
    • /
    • 2006
  • The purpose of this study is to develop a badge-type passive sampler for the measurement of short-term nitrogen dioxide and to evaluate its performance. The principle of the method is a colorimetric reaction of nitrogen dioxide with sulfanilic acid, N-1-naphthylethylendiamine, and phosphoric acid. First, it has been shown that the filter paper should be rinsed with ultrapure water and ultrasound, and then dried in a vacuumed desiccator. The concentration and volume of absorption reagent (triethanolamine) were $20\%$ and 100 ${\mu}L$, respectively. The extraction time was determined as 60 min. Second, duplicate measurements (n= 116) were carried out for evaluating the precision of the passive sampler. The relative error and the correlation coefficient between duplicates are $3.4\pm 3.0\%$ and 0.994, respectively. In addition, the $95\%$ confidence interval of intraclass correlation coefficient and the estimated value are 0.992$\sim$0.996 and 0.994, respectively. Third, a paired t-test was carried out for evaluating the accuracy of the passive sampler (n=40). In the result of the test, the $95\%$ confidence interval of the difference was -1.710 ppb <$\gamma$< 0.788 ppb. Finally, the average concentration of blanks, measurement detection limit, limit of detection, and limit of quantification are $2.4\pm 0.4$ ppb, 104 ppb, 3.8 ppb, and 7.0 ppb, respectively.

박막 가스 검지후소자의 제조에 관한 연구 (Study on the Preparation of Thin film gas sensors)

  • 이덕동;김봉열
    • 대한전자공학회논문지
    • /
    • 제18권1호
    • /
    • pp.35-40
    • /
    • 1981
  • 분무법(spray method), 화학증착법(chemical vapor deposition method) 및 진공도착법 등을 사용하여 SRO2, SROr-ZnO 및 ZnO 박막가스 검지소자를 제조하였다. 제된된 소자들은 CO 및 SO2 등 유독가스를 포함한 여러 가지 가스에 대해 민감한 반응을 나타내었다. 박막가스 검지소자가 각종 가스와 접촉할 때 생기는 전기시도도의 변화는 이들 가스의 표면흡착에 의한 캐리어밀도의 변화에 기인하는 것으로 사료된다. 아울러 제조된 청막소자의 전기부도도는 소자 주위에 유지되는 기력에 따라 크게 달라짐을 알 수 있었다.

  • PDF

감압(減壓)에 의(依)한 사과 저장중(貯藏中)의 생리화학적(生理化學的) 변화(變化)에 관(關)한연구(硏究) (Studies on the Psysio-Chemical Changes in Apple Fruits During the Storage Under Sub-atmospheric Pressure)

  • 손태화
    • Applied Biological Chemistry
    • /
    • 제19권4호
    • /
    • pp.202-218
    • /
    • 1976
  • 감압(減壓)이 사과저장(貯藏)에 미치는 영향(影響)을 보기 위하여 일정감압(一定減壓)을 유지(維持)시킬 수 있는 감압저장장치(減壓貯藏裝置)를 새로히 고안제작(考案製作)하여서 시료(試料)는 저장성(貯藏性)이 약(弱)하다는 축(祝)을 선정(選定)하여 $25^{\circ}C$에서 상압구(常壓區)와 감압구(減壓區)로 구분(區分)하고 다시 각(各) 구별(區別)로 환경기체조성(環境氣體組成)을 $CO_2$ 0%구(區) 및 $CO_2$ 5%구(區)로 조정(調整)하여 저장중(貯藏中) 호흡(呼吸), ethylene 생성량(生成量) 및 조직내기체조성(組織內氣體組成)의 변화(變化)와 아울러 성분변화(成分變化)를 조사(調査)하였던 바, 1. 조직내기체(組織內氣體)는 감압(減壓)이 설정(設定)이 동시(同時)에 급속(急速)히 조직(組織)밖으로 이동(移動)하여 5분(分) 이내(以內)에 평형(平衡)이 되었음을 보았으며, 2. 호흡량(呼吸量)은 상압구(常壓區)가 감압구(減壓區)보다 높았고 환경기체조성변화(環境氣體組成變化)에 있어서도 $CO_2$ 5%구(區)는 $CO_2$ 0%구(區)에 비하여 호흡량(呼吸量)이 적음을 볼 수 있었다. 그리고 climacteric rise의 발현(發現)도 호흡량(呼吸量)이 낮음과 병행하여 감압구(減壓區)가 상압구(常壓區)보다 지연됨을 볼 수 있었으며 이와같은 것으로 미루어 감압(減壓)이 과실호흡(果實呼吸)을 억제(抑制)하는데 효과적(效果的)인 수단(手段)임을 알 수 있었다. 이와같은 현상(現像)은 R.Q의 변화조사(變化調査)와 조직내기체조성(組織內氣體組成)의 변화조사(變化調査)에서도 찾아 볼 수 있었다. 3. 과실(果實)의 성숙(成熟) hormone인 ethylene의 생성(生成)은 호흡(呼吸)의 climacteric pattern과 병행하는 경향(傾向)이었으며 climacteric maximum stage,에서는 감압구(減壓區)가 상압구(常壓區)보다 높은 경향(傾向)이었으나 post climacteric stage이후부터 낮아짐과 아울러 조직내(組織內) ethylene농도조사(濃度調査)에서 감압구(減壓區)가 상압구(常壓區)보다 낮음을 볼 때 감압(減壓)으로 인(因)하여 과실(果實)의 ethylene생성(生成)이 억제(抑制)되는 것이 아닌가 생각된다. 4. 그리고 외관조사(外觀調査)에서 지색(地色)의 변화(變化)가 늦어짐과 신선도(新鮮度), 부패율(腐敗率), 중량감소(重量減少), 경도(硬度)의 변화(變化)에서도 위와같은 감압(減壓)의 효과(效果)를 찾아 볼 수 있었다. 5. 성분변화(成分變化) 조사(調査)에 있어서도 당분(糖分), vitamin C 및 산(酸)의 변화(變化)가 감압(減壓)이 상압(常壓)보다 적었으며 특(特)히 유기산중(有機酸中) malic acid의 감소억제효과(減少抑制效果)가 감압구(減壓區)에서 크게 나타났다. 이와같은 효과(效果)는 감산비(減酸比)에서 뚜렷함을 알 수 있었다.

  • PDF

환상형상 전극구조를 갖는 저압 RF plasma를 이용한 CF4 제거 (Abatement of CF4 Using RF Plasma with Annular Shape Electrodes Operating at Low Pressure)

  • 이재옥;허민;김관태;이대훈;송영훈;이상윤;노명근
    • 한국대기환경학회지
    • /
    • 제26권6호
    • /
    • pp.690-696
    • /
    • 2010
  • Abatement of perfluorocompounds (PFCs) used in semiconductor and display industries has received an attention due to the increasingly stricter regulation on their emission. In order to meet this circumstance, we have developed a radio frequency (RF) driven plasma reactor with multiple annular shaped electrodes, characterized by an easy installment between a processing chamber and a vacuum pump. Abatement experiment has been performed with respect to $CF_4$, a representative PFCs widely used in the plasma etching process, by varying the power, $CF_4$ and $O_2$ flow rates, $CF_4$ concentration, and pressure. The influence of these variables on the $CF_4$ abatement was analyzed and discussed in terms of the destruction & removal efficiency (DRE), measured with a Fourier transform infrared (FTIR) spectrometer. The results revealed that DRE was enhanced with the increase in the discharge power and pressure, but dropped with the $CF_4$ flow rate and concentration. The addition of small quantity of $O_2$ lead to the improvement of DRE, which, however, leveled off and then decreased with $O_2$ flow rate.

Surface Ozone Episode Due to Stratosphere-Troposphere Exchange and Free Troposphere-Boundary Layer Exchange in Busan During Asian Dust Events

  • Moon, Y.S.;Kim, Y.K.;K. Strong;Kim, S.H.;Lim, Y.K.;Oh, I.B.;Song, S.K.
    • 한국환경과학회지
    • /
    • 제11권5호
    • /
    • pp.419-436
    • /
    • 2002
  • The current paper reports on the enhancement of O$_3$, CO, NO$_2$, and aerosols during the Asian dust event that occurred over Korea on 1 May 1999. To confirm the origin and net flux of the O$_3$, CO, NO$_2$, and aerosols, the meteorological parameters of the weather conditions were investigated using Mesoscale Meteorological Model 5(MM5) and the TOMS total ozone and aerosol index, the back trajectory was identified using the Hybrid Single-Particle Lagrangian Integrated Trajectory Model(HYSPLIT), and the ozone and ozone precursor concentrations were determined using the Urban Ashed Model(UAM). In the presence of sufficiently large concentrations of NO$\sub$x/, the oxidation of CO led to O$_3$ formation with OH, HO$_2$, NO, and NO$_2$ acting as catalysts. The sudden enhancement of O$_3$, CO, NO$_2$ and aerosols was also found to be associated with a deepening cut-off low connected with a surface cyclone and surface anticyclone located to the south of Korea during the Asian dust event. The wave pattern of the upper trough/cut-off low and total ozone level remained stationary when they came into contact with a surface cyclone during the Asian dust event. A typical example of a stratosphere-troposphere exchange(STE) of ozone was demonstrated by tropopause folding due to the jet stream. As such, the secondary maxima of ozone above 80 ppbv that occurred at night in Busan, Korea on 1 May 2001 were considered to result from vertical mixing and advection from a free troposphere-boundary layer exchange in connection with an STE in the upper troposphere. Whereas the sudden enhancement of ozone above 100 ppbv during the day was explained by the catalytic reaction of ozone precursors and transport of ozone from a slow-moving anticyclone area that included a high level of ozone and its precursors coming from China to the south of Korea. The aerosols identified in the free troposphere over Busan, Korea on 1 May 1999 originated from the Taklamakan and Gobi deserts across the Yellow River. In particular, the 1000m profile indicated that the source of the air parcels was from an anticyclone located to the south of Korea. The net flux due to the first invasion of ozone between 0000 LST and 0600 LST on 1 May 1999 agreed with the observed ground-based background concentration of ozone. From 0600 LST to 1200 LST, the net flux of the second invasion of ozone was twice as much as the day before. In this case, a change in the horizontal wind direction may have been responsible for the ozone increase.