• Title/Summary/Keyword: array sensors

Search Result 478, Processing Time 0.029 seconds

Thermo-Piezoelectric Read/Write Mechanisms for Probe-Based Data Storage

  • Nam, Hyo-Jin;Kim, Young-Sik;Lee, Sun-Yong;Jin, Won-Hyeog;Jang, Seong-Soo;Cho, Il-Joo;Bu, Jong-Uk
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.47-53
    • /
    • 2007
  • In this paper, a thermo-piezoelectric mechanism with integrated heaters and piezoelectric sensors has been studied for low power probe-based data storage. Silicon nitride cantilever integrated with silicon heater and piezoelectric sensor has been developed to improve the uniformity of cantilevers. Data bits of 40 nm in diameter were recorded on PMMA film. The sensitivity of the piezoelectric sensor was 0.615 fC/nm after poling the PZT layer. And, the $34\times34$ probe array integrated with CMOS circuits has been successfully developed by simple one-step bonding process. The process can simplify the process step and reduce tip wear using silicon nitride tip.

  • PDF

Wound-State Monitoring for Burn Patients Using E-Nose/SPME System

  • Byun, Hyung-Gi;Persaud, Krishna C.;Pisanelli, Anna Maria
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.440-446
    • /
    • 2010
  • Array-based gas sensors now offer the potential of a robust analytical approach to odor measurement for medical use. We are developing a fast reliable method for detection of microbial infection by monitoring the headspace from the infected wound. In this paper, we present initial results obtained from wound-state monitoring for burn patients using an electronic nose incorporating an automated solid-phase microextraction (SPME) desorption system to enable the system to be used for clinical validation. SPME preconcentration is used for sampling of the headspace air and the response of the sensor module to variable concentrations of volatiles emitted from SPME fiber is evaluated. Gas chromatography-mass spectrometry studies prove that living bacteria, the typical infectious agents in clinical practice, can be distinguished from each other by means of a limited set of key volatile products. Principal component analysis results give the first indication that infected patients may be distinguished from uninfected patients. Microbial laboratory analysis using clinical samples verifies the performance of the system.

A Study on the Indoor Navigation of Guiding Robot for the Visually Impaired Using Sensor Fusion (센서 퓨전을 이용한 시각 장애인 유도 로봇의 실내주행 연구)

  • Jang, Chul-Woong;Jung, Ki-Ho;Yeom, Moon-Jin;Shim, Hyun-Min;Hong, Yeong-Ki;Shim, Jae-Hong;Lee, Eung-Hyuk
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.923-924
    • /
    • 2006
  • In this paper, we propose the sensor fusing method for the obstacle avoidance of guiding robot for the visually impaired In our system, we acquire obstacles distances information using ultrasonic sensors, and its width is acquired by image sensor. We also compute avoidance angle using are distance and width information gained by sensor. After the robot avoid the obstacle by computed angle, the robot returns to its original path using odometry. The robot consists of the SA1110-based controller, sensory part using sonar array and image sensor, and motion part using differential drive for climbing stairs. This system use the embedded linux for OS, and also is developed by the QT/Embedded for GUI.

  • PDF

A Temperature-Controllable Microelectrode and Its Application to Protein Immobilization

  • Lee, Dae-Sik;Choi, Hyoung-Gil;Chung, Kwang-Hyo;Lee, Bun-Yeoul;Pyo, Hyeon-Bong;Yoon, Hyun-C.
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.667-669
    • /
    • 2007
  • This letter presents a smart integrated microfluidic device which can be applied to actively immobilize proteins on demand. The active component in the device is a temperature-controllable microelectrode array with a smart polymer film, poly(N-isopropylacrylamide) (PNIPAAm) which can be thermally switched between hydrophilic and hydrophobic states. It is integrated into a micro hot diaphragm having an integrated micro heater and temperature sensors on a 2-micrometer-thick silicon oxide/silicon nitride/silicon oxide (O/N/O) template. Only 36 mW is required to heat the large template area of 2 mm${\times}$16 mm to $40^{\circ}C$ within 1 second. To relay the stimulus-response activity to the microelectrode surface, the interface is modified with a smart polymer. For a model biomolecular affinity test, an anti-6-(2, 4-dinitrophenyl) aminohexanoic acid (DNP) antibody protein immobilization on the microelectrodes is demonstrated by fluorescence patterns.

  • PDF

Adaptive Spatial Domain FB-Predictors for Bearing Estimation (입사각 추정을 위한 적응 공간영역 FB-예측기)

  • Lee, Won-Cheol;Park, Sang-Taick;Cha, Il-Whan;Youn, Dae-Hee
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.160-166
    • /
    • 1989
  • We propose adaptive algorithms computing the coefficients of spatial domain predictors. The method uses the LMS approach to compute the coefficients of the predictors realized by using the TDL(tapped-delay-line) and the ESC (escalator) structures. The predictors to be presented differ from the conventional ones in the sense that the relevant weights are updated such that the sum of the mean squared values of the forward and the backward prediction errors is minimized. Using the coefficients of such spatial domain predictors yields improved linear predictive spatial spectrums. The algorithms are applied to the problems of estimating incident angles of multiple narrow-band signals received by a linear array of sensors. Simulation results demonstrating the performances of the proposed methods are presented.

  • PDF

Application of Electronic Nose in Biotechnology (바이테크놀로지 분야에서의 전자코 이용)

  • Lim, Chae-Lan;Noh, Bong-Soo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.401-408
    • /
    • 2007
  • It's not easy to detect the specific compounds from various compounds that fermented in bioreactor. The electronic nose was an instrument, which comprised of an array of electronic chemical sensors with partial specificity and an appropriate pattern recognition system, capable of recognizing simple or complex volatiles. It can conduct fast analysis and provide simple and straightforward results and is best suited for quality control and process monitoring in field of biotechnology. This review examined the application of electronic nose in biotechnology and brief explanation of its principle. In this minireview numbers of applications of an electronic nose in biotechnology include monitoring fermentation process, to overcome interference with alcohol, and to detect contaminant microorganism were discussed. The electronic nose would be useful for a wide variety of biotechnology when correlating analytical instrumental data with the obtained data from electronic nose.

Source Localization in the Anechoic Basin at KRISO/KORDI by Using MUSIC Algorithm (무향수조 내에서 MUSIC 알고리듬을 이용한 음원의 위치 추적)

  • Kim, Sea-Moon;Choi, Young-Cheol;Lee, Chong-Moo;Park, Jong-Won;Lim, Yong-Kon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.68-72
    • /
    • 2002
  • Localization with array sensors has been applied for not only military but also non-military purposes. The identification of submarines and fish finding are those examples. Nowadays the demand for noise identification is increasing to characterize noise sources and improve acoustic performance of underwater acoustic equipment. For that reason KRISO/KORDI recently constructed an anechoic basin which bus reflection only at the free surface. This paper suggests a noise identification methods using MUSIC algorithm in such an acoustic field. For comparison phase delay sum and minimum valiance methods are also described. At first basic principles are described. A several numerical simulations are also performed. The results say that reflection effect many cause a new non-real source although good estimation is obtained under no reflection conditions.

  • PDF

Sensitivity Analysis of Long Baseline System with Three Transponders (세 개의 트랜스폰더로 이루어진 장기선 위치추적장치의 민감도 해석)

  • Kim, Sea-Moon;Lee, Pan-Mook;Lee, Chong-Moo;Lim, Yong-Kon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.27-31
    • /
    • 2003
  • Underwater acoustic navigation systems are classified into three systems: ultra-short baseline (USBL), short baseline (SBL), and long baseline (LBL). Because the USBL system estimates the angle of a submersible, the estimation error becomes large if the submersible is far from the USBL transducer array mounted under a support vessel. SBL and LBL systems estimate submersible's location more accurately because they have wider distribution of measuring sensors. Especially LBL systems are widely used as a navigation system for deep ocean applications. Although it is most accurate system it still has estimation errors because of noise, measurement error, refraction and multi-path of acoustic signal, or wrong information of the distributed transponders. In this paper the estimation error of the LBL system are analyzed from a point of sensitivity. It is assumed that the error exists only in the distance between a submersible and the transponders. For this purpose sensitivity of the estimated position with respect to relative distances between them is analyzed. The result says that estimation error is small if the submersible is close to transponders but not near the ocean bottom.

  • PDF

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

Fabrications and Characteristics of Infrared Sensor Composed of λ/4 Absorbing Structure for the Application of NDIR CO2 Gas Sensor (λ/4 흡수층 구조를 갖는 NDIR 이산화탄소 가스센서용 적외선 센서의 제조 및 특성)

  • Lee, Sung-Hyun;Nam, Tae-Woon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1005-1009
    • /
    • 2008
  • A noble infrared $\lambda/4$ absorbing structure using metal reflector was studied for uncooled infrared sensors. This paper described the design and the fabrication of IR uncooled detectors which were composed of 21 by 21 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of 4.26 ${\mu}m$. The fabricated detectors exhibited the thermal mass of $9.75\times10^{-9}$ J/K, the thermal conductance of $1.31\times10^{-6}$ W/K, the thermal time constant of 7.4 ms, the responsivity of $1.07\times10^5$ V/W and the detectivity of $1.04\times10^9$ $cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of 9.22${\mu}A$. Finally the absorptance efficiency of $\lambda/4$ absorbing structure was about 23.2 % higher than that of absence absorbing structure.