• Title/Summary/Keyword: antibody-antigen reaction

Search Result 170, Processing Time 0.025 seconds

Correlation of Axillary Artery Pressure and Phase of Esophageal Impedance in Chickens

  • Nakajima, Isao;Kuwahira, Ichiro;Hori, Shuho;Mitsuhashi, Kokuryo
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • Under General anesthesia with isoflurane, we insert a chicken's esophageal catheter into the near the left atrium. 1MHz radio wave was added to electrocardiogram electrodes of the esophagus, and the change of impedance (phase) was obtained by amplitude synchronous detection technique. At the same time, a thin tube is surgically inserted into the axillary artery to continuously measure blood pressure. The correlation between impedance (phase) and blood pressure was obtained. Both showed a very high correlation (R2=0.9665). It was also observed the waveform flowing from the left atrium into the left ventricle. When an individual infected with the avian influenza virus develops, the cytokine storms lead to hypotension earlier than the test for antigen-antibody reaction. In order to detect this, in the future, this impedance technique will be useful for screening individuals infected with avian influenza virus by measuring the blood pressure of chickens in cages in a non-contact manner using microwaves.

Studies on the Applicability of Various Antigen Preparations in the Immunoblot Diagnosis of Cysticercosis (Immunoblot법을 이용한 낭미충증(囊尾蟲症)진단에 있어서 각종 항원(抗原)의 적용가능성(適用可能性) 검토(檢討)에 관한 연구(硏究))

  • Koh, Young-Tae;Joo, Kyoung-Hwan;Chung, Myung-Sook;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.16 no.1
    • /
    • pp.79-89
    • /
    • 1991
  • A systematic study was conducted to identify and isolate a serologically pertinent antigen with high specific activity and low cross reactivity from Cysticercus parenchymal antigen. Differential centrifugation of the homogenate yield three particulate and one soluble fractions ; the $480{\times}G$ pellets($CyL_2$), the $7650{\times}G$ pellet($CyL_3$), the $100000{\times}G$ pellet($CyL_4$), and $100000{\times}G$ supernatant($CyL_6$). We compared antigenicity of these antigens to that or cystic fluid antigens($CyF_1$), saline extract of cystic wall($CyL_1$), and n-butanol treated $GyL_4$ antigen ($CyL_6$) based on SDS-PAGE and immunoblot techniques. The data obtained were as follows : 1) The ratio of O.D. value of ELISA against cysticercosis positive pool sera to that of negative pool sera was highest when using $CyF_1$ as antigen. However the ratio was relatively low in case of $CyL_{3.4}$ and $CyL_5$. 2) We have noted in previous paper that most strong antigenic activities are present in 63Kd band with low cross reactivities. An effective serologic reagent must contain components that are recognized by most infected sera. 63Kd band met this criteria and could be considered as a reliable band for the diagnosis of cysticercosis. As far as 63Kd band concern, $CyL_5$ showed most strong activities without disturbance of cross reaction by EITB in spite of low applicability to microplate ELISA. 3) $CyL_5$ could detect the serum antibody of cysticercosis even in very low titers, around cut-off values of microplate ELISA, by immunoblot. It also could detect the cross reactivities of Echinococcus species, which showed high absorbance value in micro plate ELISA and some sparganosis cases. Further purification of this antigen will be able to represents a antigen that can be used in the diagnosis of cysticercosis.

  • PDF

Nonspecific Mouse Hepatitis Virus Positivity of Genetically Engineered Mice Determined by ELISA

  • Han, Dae Jong;Kim, Hyuncheol;Yeom, Su-Cheong
    • Biomedical Science Letters
    • /
    • v.21 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Mouse hepatitis virus (MHV) is a major pathogen in laboratory mice that usually leads to fatal diseases, such as hepatitis, multiple sclerosis, encephalitis, and respiratory disease. MHV has a high infection rate, and it needs to be detected as soon as possible to prevent its spread to other facilities. However, MHV detection by enzyme-linked immunosorbent assay (ELISA) often gives false positives; thus, it is very important that the results are confirmed as true positives in the early infection stage or distinguished as false positives with more accurate, reliable methods. Under microbiological screening, MHV ELISA-positive mice were found in four GFP-tagging transgenic mice. To verify the detection of the MHV antigen directly, reverse transcription polymerase chain reaction (RT-PCR) was performed, and the mice were determined to be MHV negative. Additional serum antibody-based screening was conducted with three different ELISA kits, and multiplexed fluorometric immunoassay (MFIA) was performed to confirm their accuracy/sensitivity. In brief, the ELISA kit for A59 nucleocapsid protein (MHV-A59N) revealed MHV ELISA positivity, while other ELISA kits (MHV-S lysate and MHV-JHM lysate) demonstrated MHV negativity. In MFIA, only the test for the recombinant A59 nucleocapsid antigen was MHV positive, which was consistent with the ELISA results. These results suggest that the ELISA kit with the recombinant A59 nucleocapsid antigen might induce non-specific MHV ELISA positivity and that confirmation is therefore essential.

A Study on the Antigen Characteristics of Rhodotorula rubra (Rhodotorula rubra의 항원특성에 관한 연구)

  • Kwon, Hyuk-Ku;Lee, Jang-Hoon;Ryeon, Kon
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.28-34
    • /
    • 2002
  • Antigenicity of Rhodotrula rubra isolated from pulmonary tissue of pulmonary tuberculosis patients was studied by means of agglutination reaction with R. rubra whole cell antiserum. And the serological reactivity of crude polyfac charide from R. frubra, Candida albicans, Candida tropicalis, Candida, glabrata, and Saccharomyces cerevisiae ATCC 26603 with antiserum to R. rubra whole cell was studied by means of immunodiffusion test. R. rubra showed stationary phase after 48h when it was cultured in GYEP broth. While agglutinogen titer was 1:64 at lag phase, agglutinogen titer was 1 :256 after 20h. After growth of R. rubra on different 11 media, nutritional environment showed similar agglu-tination reartivity. The agglutinogen titer of C. albicans, C. tropicalis, C. giabrata, which were isolated from patient's expectoration, to R. rubra antiserum by means of agglutination reaction were 1:16, respectively. But, Sacch. cervisiae ATCC26603 was negative. Those results were lower than that of R. rubra agglutinogen titer 1:256. As a result of immu-nodiffusion test with crude polysaccharide extracted from cell wall of R. rubra, C. albicans, C. tropicalis, C. glabrata, Sacch. cervisiae ATCC26603, precipitin line was found only with R. rubra, of which antibody titer was 8.

A seroepidemiological survey for toxocariasis in apparently healthy residents in Gangwon-do, Korea

  • Park, Hyun-Young;Lee, soo-Ung;Huh, Sun;Kong, Yoon;Magnaval, Jean-Francois
    • Parasites, Hosts and Diseases
    • /
    • v.40 no.3
    • /
    • pp.113-117
    • /
    • 2002
  • We investigated the sero-prevalence of toxocariasis among healthy Korean adults in 1999. A total of 314 sera from normal inhabitants in Whachon-gun, Gangwon do, Korea was examined for specific antibody levels against excretory-secretory products of second stage larvae of Toxocara (TES). The presence of cross-reactions with other helminthiases such as cysticercosis, paragonimiasis, sparganosis or clonorchiasis was also checked by specific IgG ELISA. Sera showing positive reaction against TES were also tested by IgG immunoblot and by IgE ELISA. Out of 314 subjects, 16 was found to be positive by TES IgG ELISA and immunoblot, among whom 12 were also positive by TES IgE ELISA. Among the 16 seropositive samples, two sera showed positive reaction against Paragonimus and sparganum antigen, respectively. These results inferred that cross-reactions were negligible between toxocariasis and other helminthiases. Toxocariasis seroprevalence among Korean rural adults was detected to be approximately 5%.

Fiber-Optic Sensor Simultaneously Detecting Localized Surface Plasmon Resonance and Surface-Enhanced Raman Scattering

  • Norov, Erdene;Jeong, Hyeon-Ho;Park, Jae-Hyoung;Lee, Seung-Ki;Jeong, Dae Hong
    • Rapid Communication in Photoscience
    • /
    • v.2 no.2
    • /
    • pp.46-51
    • /
    • 2013
  • This study reports a fiber-optic sensor detecting biomolecule by simultaneously monitoring localized surface plasmon resonance (LSPR) from gold nanoparticles (Au NPs) of ca. $50{\pm}5$ nm attached on one end of optical fiber and surface enhanced Raman scattering (SERS) of the reporter molecules adsorbed on the gold surfaces as an additional sensing tool. The sensor was fabricated by immobilizing Au NPs on one end of an optical fiber by chemical reaction. LSPR and SERS signals of the sensor were measured using various refractive indices solutions. Finally, the sensor was applied to observe real-time LSPR sensor-gram and SERS spectra of the reporter molecule of 4-aminothiphenol during the antibody-antigen reaction of interferon-gamma (IFN-${\gamma}$) as a proof-concept experiment of biological applications.

Production of Mn-peroxidase and Laccase from Lentinus edodes and Coriolus versicolor (표고 및 구름버섯으로부터 Mn-peroxidase와 Laccase의 생산(生産))

  • Bae, Hyeun-Jong;Han, Ok-Soo;Koh, Hong-Bum;Kim, Yoon-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.87-93
    • /
    • 1993
  • This study was undertaken to investigate the characteristics and the productivities of lignin olytic enzymes: laccase (Lac) and Mn-dependent peroxidase (MnP) from Coriolus versicolor and Lentinus edodes respectively. Enzymes were isolated from cultural filterates and purified according to the standard methods. These enzymes showed one band in SDS-PAGE and their molecular weights were found 62,000 and 45,000 dalton respectively. Polyclonal antibodies against Lac and MnP were raised against mouse. In the ELISA (enzyme-linked immunosorbent assay), Lac and MnP-antiserum produced a strong positive reaction with Lac and MnP antigen($A_{405}$=2.50 and 3.53 respectively). The sera to negative (S/N) ratio was determined by the dividing the mean absorbance of antibodies by the corresponding diluted samples from normal mouse serum. The sera produced showed 2 times more positive reaction in S/N ratio than negative sera.

  • PDF

Nanobiocatalyst-Linked Immunosorbent Assay(NBC-LISA) (나노바이오촉매 기반 효소결합면역흡착검사)

  • Lee, Inseon;Hwang, Sang Youn;Kim, Jungbae
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.387-392
    • /
    • 2011
  • Enzymes are being used in various fields due to their unique property of substrate specificity. Enzyme-linked immunosorbent assay(ELISA) has enabled the detection of various antigens by reporting the binding event of antigen and antibody via enzyme-catalyzed reaction. However, the sensitivity improvement of conventional ELISA has been limited because only one enzyme molecule is conjugated to one molecule of antibody. To overcome this limitation and further improve the sensitivity of ELISA, there have been efforts to increase the number ratio of enzymes to antibody. Recently, the nanobiocatalytic approaches, with their successful enzyme stabilization, improved the performance stability as well as sensitivity in a modified protocol of ELISA. The present paper introduces the basic principle of ELISA, and the recent efforts to improve sensitivity and performance stability of ELISA by using the nanobiocatalytic approaches.

Serological Cross-Reactivity between Sarcocystis and Toxoplasma in Pigs (돼지에 있어서 Sareocustis와 Toxoplusma 감량의 혈청학적 교차반응 시험)

  • 문무홍
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.188-194
    • /
    • 1987
  • The development of antibody titers and crossreaction between Sarcocystis and Toxoplasma were investigated by means of IF A test and ELISA in pigs experimentally infected with $1.5{\times}10^6$ S. suicanis sporocysts and 10,000 T. gondii oocysts, respectively. The intact and soluble Sarcocystis antigens were prepared from the bradyzoites harvested by peptic digestion of infected pork. The intact and soluble Toxoplasma antigens were prepared from the tachyzoites in mouse peritoneal cavity. IgG antibodies in pigs infected with Sarcocystis and Toxoplasma, respectively were detected first at 2 weeks post infection on both IF A test and ELISA. The antibody titer to Toxoplasma reached its maximum at 6 weeks post infection and decreased thereafter. The antibody titer to Sarcocystis reached its maximum terminally. The cross-reaction titer in pigs infected with Toxoplasma against Sarcocystis antigen was up to 1 : 16 in IFA test and up to 1 : 32 in ELISA. The titer in control group was below 1 : 4 in both reactions.

  • PDF

Radioimmunoscintigraphy Using IMACIS-1 in Gastrointestinal Cancer (IMACIS-1을 이용한 위장관 종양의 방사면역신티그램)

  • Sohn, Hyung-Sun;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.29-36
    • /
    • 1990
  • Most of the diagnostic methods currently used for the detection of neoplastic masses provide indirect evidence. To obtain greater specificity in the interpretation of neoplasias by in vivo methods, the immunological approach appears to be most promising. Two problems that interfered with progress in this field were the lack of tumor specific antigen and the lack of well-defined and reproducible antibodies. To improve the sensitivity and specificity of radioimmunoscintigraphy as a technique for tumor localization, the use of monoclonal antibodies, fragments of antibodies and single photon emission computerized tomography (SPECT) are reasonable. The obvious advantages of monoclonal antibodies are their homogeneity, their specificity for the immunizing antigen and the reaction with a single determinant-thus no large immunecomplexes with antigen are formed. Monoclonal antibody technique has recently provided an opportunity to reevaluate the role of nuclear medicine for the diagnosis of malignant diseases by using the immunological approach. Out first results by means of radioimmunoscintigraphy of CEA and CA 19-9 producing tumors using a cocktail of fragments F $(ab')_2$, of mocolonal antibodies to CA 19-9 and CEA labeled with $^{131}I$ (IMACIS-1) are reported. The aims of this investigation was to evaluate the role of immunoscintigraphy in patients with colorectal and other cancers for diagnosis of local recurrences and metastasis. This report contains results of the first 8 colorectal and pancreas cancer patients with the elevation of the level of serum CEA and/or CA 19-9. IMACIS-1 was injected intravenously during 30 minutes in 100 ml saline solution after skin test. Planar scintigrams were recorded 3, 5 and 7 days after the injection of the IMACIS-1. Anterior, lateral and posterior views of the liver as well as anterior and posterior views of the pelvis were obtained in each patients as an $^{131}I-antibody$ image. We were able to localize exactly the malignant process with the double-nuclide double-compound $^{99m}Tc\;^{131}I$ (Tc+l) scintigrams. In Tc & I double-nuclide scintigraphy, computer subtraction display provided more clear localization of the tumor. We compared the results of radioimmunoscintigraphy with CT, ultrasonograms, conventional scintigrams. The results were as follows: 1) The sensitivity and specificity of radioimmunoscintigraphy using the fragments $F(ab')_2$ of the cocktails of CEA and CA 19-9 monoclonal antibodies were 80% and 100% respectively. 2) Tumor detection rate was not proportionated to the level of serum tumor markets. 3) Second tracer technique was essential for tumor localization as an anatomic landmark using double-nuclide scintigraphy. 4) A slow infusion of the antibodies was necessary to prevent the formation of large immune complexes. 5) Tumor/non-tumor radioactivity was most elevated at 7 days delayed imaging. 6) Using planar scintigraphic technique of $^{131}I$ labeled monoclonal antibodies are possible for imaging most of the tumors.

  • PDF