• Title/Summary/Keyword: angle standard

Search Result 925, Processing Time 0.029 seconds

On The Optimal Generation Using The Loss Sensitivities Derived by Angle Reference Transposition (손실감도를 이용한 계통손실 최적화에 대하여)

  • Yang, Seong-Deog;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.59-63
    • /
    • 2005
  • In this article, we apply the standard method of Lagrange multipliers to examine the algorithm in a recent IEEE publication which calculates the optimal generation for minimizing the system loss using loss sensitivities derived by angle reference transposition, and show that the two algorithms are mathematically the same.

Analysis of Two-Dimensional Turbulent Flow around the Horn-type Rudder (Horn-type Rudder 주위의 2 차원 난류유동 해석)

  • Jeong, Nam-Gyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.924-931
    • /
    • 2009
  • The two-dimensional turbulent flow around the horn-type rudder has been examined in the present study by using the commercial code FLUENT. The standard ${\kappa}-{\epsilon}$ model is used as a closure relationship. The geometry of horn rudder is based on the NACA 0020 airfoil. The simulations for various angle attack (${\alpha}$) and yaw angle(${\delta}$) are carried out. The effect of Reynolds number is also investigated in this study. The cavitation is more possible when the yaw angle is $6^{\circ}$ and it is more serious as Reynolds number increases.

A Study on Usefulness Verification Technique of the Measurement System by the Difference Between Caculated and Experimental Values of Ratio Error/phase Annie Error in Current Transformer (전류변성기의 비오차와 위상각오차의 계산값과 실험값의 차에 의한 측정시스템 유용성 검증기술에 관한 연구)

  • 정재갑;권성원;이상화;박영태
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.213-217
    • /
    • 2004
  • A current transformer(CT) used for the estabilishment of high current national standard, has generally very small ratio error and phase angle error. Both the errors of CT depend critically on the external burden used. When both the ratio and phase angle errors at two different burdens including zero burden are known, those at any other burdens are calculated theoretically. The theoretical values are well consistent with the experimental results within the $82{\times}10$-6, implying the measurement system of CT in KRISS is well maintained.

Prediction method of slope hazards using a decision tree model (의사결정나무모형을 이용한 급경사지재해 예측기법)

  • Song, Young-Suk;Chae, Byung-Gon;Cho, Yong-Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1365-1371
    • /
    • 2008
  • Based on the data obtained from field investigation and soil testing to slope hazards occurrence section and non-occurrence section in gneiss area, a prediction technique was developed by the use of a decision tree model. The slope hazards data of Seoul and Kyonggi Province were 104 sections in gneiss area. The number of data applied in developing prediction model was 61 sections except a vacant value. The statistical analyses using the decision tree model were applied to the entrophy index. As the results of analyses, a slope angle, a degree of saturation and an elevation were selected as the classification standard. The prediction model of decision tree using entrophy index is most likely accurate. The classification standard of the selected prediction model is composed of the slope angle, the degree of saturation and the elevation from the first choice stage. The classification standard values of the slope angle, the degree of saturation and elevation are $17.9^{\circ}$, 52.1% and 320m, respectively.

  • PDF

On-Site Evaluation Technique of Linearity for Ratio Error and Phase Angle Error of Current Transformer Comparison Measurement Equipment (전류변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 현장 평가기술)

  • Jung, Jae-Kap;Kwon, Sung-Won;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.313-316
    • /
    • 2006
  • A method for evaluation of the linearity of both the ratio error and phase angle error in the current transformer(CT) comparison measurement equipment has been developed by employing the standard resistors with negligible AC-DC resistance difference less than $10^{-5}$. The non-reactive standard resistors for the linearity check of the system are used as the external burden connected with the secondary of CT under test. These burdens consist of nine standard resistors, with the nominal resistance of $0.01{\Omega},\;0.1{\Omega},\;0.2{\Omega},\;0.4{\Omega},\;0.6{\Omega},\;1{\Omega},\;2{\Omega},\;4{\Omega}$, and $10{\Omega}$. For linearity check, the developed method has been applied in the CT comparison measurement equipment belonging to the industry.

Finite Element Analysis and Material Mechanics of Paper Angle (종이 앵글 포장재의 재료역학적 특성과 유한요소해석)

  • Park J. M.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.6 s.113
    • /
    • pp.347-353
    • /
    • 2005
  • Paper angle, environment friendly packaging material, has been mainly used as an edge protector, But, in the future, paper angle will be applied to package design of heavy product such as strength reinforcement or unit load system (ULS). Therefore. understanding of buckling behavior fur angle itself, compression strength and quality standard are required. The objectives of this study were to characterize the buckling behavior by theoretical and finite element analysis, and to develop compression strength model by compression test for symetric and asymetric paper angle. Based on the result of theoretical and finite element analysis, as applied load level was bigger and/or the length of angle was longer, incresing rate of buckling of asymmetric paper angle was higher than that of symmetric paper angle. Decreasing rate of minimum principal moment of inertia significantly increased as the extent of asymmetric angle increased, and buckling orientation of angle was open- direction near the small web. Incresing rate of maximum compression strength (MCS) for thickness of angle decreased as the web size increased in symmetric angle. MCS of asymmetric angle of 43${\times}$57 and 33${\times}$67 decreased $15{\~}18\%$ and $65{\~}78\%$, and change of buckling increased $12{\~}13\%$ and $62{\~}66\%$, respectively.

Mechanical Behavior Analysis and Strength Standardization of Paper Angle (종이 앵글의 역학적 거동 분석과 강도 표준화 연구)

  • Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • Paper angle, environment friendly packaging material, has been mainly used as an edge protector. But, we have perceived its application to package design of heavy product such as strength reinforcement or unit load system (ULS) in the future. Above all, understanding of buckling behavior for angle itself and compression strength and quality standard have to be accomplished for the paper angle to be used for this purpose. The purpose of this study was to elucidate the buckling behavior through theoretical and finite element analysis, and to develop compression strength model by compression test for symetric and asymetric paper angle. Based on the result of theoretical and finite element analysis, increasing rate of buckling of asymmetric paper angle was higher as applied load level was bigger and/or the length of angle was longer than that of symmetric paper angle. Decreasing rate of minimum principal moment of inertia was remarkably increased as the extent of asymmetric angle is bigger, and buckling orientation of angle was open direction near the small web. Increasing rate of maximum compression strength (MCS) for thickness of angle was smaller as the web size was bigger in symmetric angle. MCS of asymmetric angle of $43{\times}57$ and $33{\times}67$ was decreased $15{\sim}18%$ and $65{\sim}78%$, and change of buckling was increased $12{\sim}13%$ and $62{\sim}66%$, respectively.

  • PDF

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

Effect of High heel on Lumbar and sacral curve (하이힐이 요부 및 천골경사각에 미치는 영향)

  • Lee, Tae-Sik;Song, Min-Young;Kim, Mi-So
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.4
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose : This study is to know how position change in high-heels affects sacral tilt angle. 15 healthy women aged 21.87(standard deviation=3.54) were tested. Method : Lumbar and sacral tilt angle was measured by radiography barefooted, and after 15 mins of application time, they were measured in the same way in high-heels. Result : There was not notable difference in lumbar lordosis, lumbosacral angle, and sacral tilt angle. However, there was differences in change degree, which was measured by estimation data of [post-pre)/pre]${\times}$100. Conclusion : There was no notable difference in lumbar lordosis, lumbosacral angle, and sacral tilt angle, but as there were differences in change degree, research about how women's lumbar change when heel height increases is needed.

  • PDF

Factors Related to Q Angle in Healthy Adults (20대 정상성인의 대퇴사두근각(Q angle)에 영향을 미치는 요인)

  • Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.6 no.1
    • /
    • pp.1-14
    • /
    • 1999
  • The quadriceps angle (Q angle) has been used to reflect the quadriceps muscle's force on the patella in the frontal plane. Previous investigations of the Q angle and it's relationship to knee disorders have yield equivocal results. The purpose of this study was to analyze the factors related to the Q angle and it's relation to other variables such as leg length, body weight, CTA (calcaneus to tibia angle), TOA (toe out angle), and pelvic width in normal subjects. The participants were 60 students (30 men and 30 women) who had no orthopedic and neurological impairments, aged from 20 to 29 years of age, with an average age of 22.1 years. Prior to participation, each subject was informed of the procedures of the experiment from a researcher and assistant researchers. The equipment used in this study were modified standard goniometer, ruler, marking pen, and Martin apparatus for pelvic width. In order to determine the statistical significance of the experiment, regression analysis, independent t-test, and Pearson correlation were used at the 0.05 level. The results were as follows: 1) It was found that the Q angle of women is greater than that of men's from both knees. 2) There was no significant difference between right and left quadriceps angle. 3) The Q angle decreased as the body weight (leg length) shifted from low to high. 4) It seems that factors related to the Q angle were body weight, CTA, and pelvic width, but there was no significant difference at the 0.05 level.

  • PDF