• 제목/요약/키워드: and technologic element

검색결과 46건 처리시간 0.017초

Ti-Nb계 합금의 상변화가 기계적 성질에 미치는 영향 (Effects of phase changes on mechanical properties of Ti-Nb alloys)

  • 박효병
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.9-17
    • /
    • 2005
  • The use of titanium alloys as biomaterials is increasing due to their superior biocompatibility and enhanced corrosion resistance compared to conventional stainless steels and cobalt-based alloys. Ti-6Al-4V ($\alpha+\beta$type) alloy instead of pure titanium ($\alpha$type) is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. But it has been reported recently that the vanadium element expresses cytotoxicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. In order to overcome their detrimental effects, $\beta$-phase stabilizer Nb was chosen in the present study. This paper was described the influence of phase changes of Ti-Nb alloys on mechanical properties. Ti-3wt.%Nb($\alpha$type),Ti-20wt.%Nb($\alpha+\beta$type) and Ti-40wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. The specimens were homogenized at 1050$^{\circ}C$ for 24hr and were then hot rolled to 50% reduction. Each alloys were solution heat treated at $\beta$ zone and $\alpha+\beta$ zone after homogenization and then were aged. The mechanical properties of Ti alloys were analysed by hardness test, tensile test, elongation test and SEM test. The results can be summarized as follows: 1) The higher hardness value of $\alpha+\beta$type alloy was obtained compared to the, $\alpha,\beta$type alloys. 2) The aged treated showed better hardness compared to the solution heat treated, homogenized. 3) In the case of solution and aging treatment at $\beta$region, the $\alpha+\beta$type alloy showed the most highest tensile strength and $\beta$type alloy showed the best elongation.

  • PDF

개(犬)의 교합력 관찰을 위한 견치와 열육치의 3차원 유한요소 분석 (Three-Dimensional Finite element analysis of Canine and Carnassial for Observation of Dog Bite forces)

  • 박유진;김치영;최성민
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.295-301
    • /
    • 2019
  • Purpose: This study is for the prosthesis of dogs. Observe the occlusal relation between the dog's canine and carnassial teeth. The strength and the direction of the occlusal by 3D FEM analysis. Methods: The mandibular canine and carnassial of dogs were tested. The dog's skull was contact point confirmed by dental CAD. The skull of the dog was 3D modeled by CT. The 3D model was analyzed by ABAQUS. Opening and closing movement has been a force of 100N, 200N, 300N, 500N, 1000N, 1,500N. The peak von Mises stress distribution was confirmed. Results: As occlusal force increased, stress appeared to 1.34 MPa, 3.32 MPa, 5.00 MPa, 6.19 MPa, 5.58 MPa, 5.47 MPa in left canine. and Stress was seen at 2.10 MPa, 3.08 MPa, 3.89 MPa, 5.50 MPa, 7.04 MPa, 7.18 MPa in the right canine. Stress appeared at 2.41 MPa, 3.53 MPa, 5.15 MPa, 7.28 MPa, 31.26 MPa, 67.22 MPa in the left carnassial. and Stress was seen at 1.57 MPa, 2.96 MPa, 3.76 MPa, 6.01 MPa, 20.94 MPa, 64.38 MPa in the right carnassial. Conclusion: Peak von Mises stress values were found at the peak of the canine, the buccal of the central cusp of the carnassial, and the occlusal surface of the distal cusp.

치기공과 임상실습 평가항목의 내용구성과 배점에 관한 연구 - 재학생 중심으로 - (A Study on Content Organization and Assigning Score of Evaluation Elements of Clinical Practice of Dept. of Dental Technology - Centering on the undergraduates -)

  • 이화식;배봉진;박명호
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.73-82
    • /
    • 2008
  • This study has been analyzed to write an ideal training evaluation table after analyzing validity of content organization and assigning score of evaluating elements of clinical practice of Dept. of dental technology. 220 junior students who are studying dental technology in D university in Daegu were questioned to analyze the relationship of content organization and score of clinical practice evaluation table. The corrected material has been inspected by SAS V8 for Windows. The results are as following. 1. The validity of content organization of clinical practice evaluation table has a result which can be reliable over than 70% but the validity of score shows low reliance. c 2. The validity of content organization of detail elements of clinical practice evaluation shows that overuse of material and attentiveness(3.78) and responsibility (3.60) are high response but in score organization, the validity shows that safety measure(2.36) when controling machines, arrangement(2.98) after use and ability (2.98) of solving problems are very low. 3. In the elements without interpersonal relation, it shows that those are related to each other. its grading is p < 0.01 so it appears to be meaningful. 4. In result of analyzing the effect to 'studying amount' mark in clinical practice evaluation mark, it appears the element of attitude for job to affect it. And in result of analyzing the effect to 'training attitude' mark, it appears the element of 'controling machines' to affect it. For these results, to be a better evaluation tool, it should be modified by continuous research with arranging evaluation elements to be marked differently in between elements.

  • PDF

Sinfony 간접복합수지와 비귀금속합금간의 전단결합강도와 파절양상 (Shear Bond Strength and Failure Mode between Sinfony Indirect Composite Resin and Non Precious Metal)

  • 민병록;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.79-86
    • /
    • 2008
  • The purpose of this study was to investigate the effect retention element formed by metal surface treatment method on the bond strength of indirect composite resin and metal. The metal specimens were cast from Ni-Cr alloy($Rexillium^{(R)}$ III). They were divided into 5 groups by applied retention element: $50{\mu}m$ aluminium oxide sandblasting group, $250{\mu}m$ aluminium oxide sandblasting group, 0.2mm retention crystal group, 10% $H_{2}SO_{4}$ solution etching group, $110{\mu}m$ $Rocatec^{TM}$ Plus system group. Total 50 metal specimens were veneered with Sinfony indirect composite resin system. Specimens were tested for shear bond strength on an Instron universal testing machine and fracture mode of fractured specimens were analyzed by SEM and EDS. 1. 0.2 mm retention crystals were most effective in improving the resin-metal shear bond strength (p<0.05). 2. Sandblasting by $250{\mu}m$ aluminium oxide were more effective than sandblasting by $50{\mu}m$ aluminium oxide in improving the resin-metal shear bond strength(p<0.05). 3. Fracture mode of resin-metal fractured surface were cohesive failure mode in 0.2mm retention crystal, mixed failure mode in sandblasted specimens, etched specimens and the specimens sandblasted with $110{\mu}m$ $Rocatec^{TM}$ Plus system.

  • PDF

임플란트 지대주 재질에 따른 지대주나사의 유한요소 응력 분석 (A Finite element stress analysis of abutment screw according to the implant abutment material)

  • 김남식;이명곤;홍민호
    • 대한치과기공학회지
    • /
    • 제38권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The present study was to determine the stress distribution of an abutment screw according to implant abutment material. Methods: This study was a tightening torque 10 Ncm, 20 Ncm, set to 30 Ncm, and a titanium alloy (Ti-6Al-4V), PEEK (polyetheretherketone), Endoligns (60% Carbon Fiber Reinforced PEEK) material of the custom abutment titanium alloy (Ti-6Al-4V) the stress distribution in the material of the abutment screw will be evaluated by the finite element analysis. Results: Abutment screw most stress has been concentrated on the interface between the fixture and the abutment was also part of the interface that the threads are started. Depending on the abutment of the abutment screw Material von Mises stress values are shown differently. 10Ncm T10 under the tightening torque of 294.2 MPa, P10 is 562.8 MPa, appeared to E10 is 295.8 MPa, 20Ncm tightening torque under T20 is 581.1 MPa, P20 is 1125 MPa, E20 was shown to 585.1 MPa, 30Ncm tightening torque under T30 is 918.2 MPa, P30 is 1795 MPa, E30 has appeared 925.1 MPa. Conclusion: If the abutment is used as Endoligns, it was confirmed that the abutment screw exhibits of von Mises stress value is similar to the titanium alloy abutment.

도재용착주조관용 Ni-Cr계 합금의 조성에 따른 표면특성 및 전단결합강도 관찰 (The Surface Property and Shear Bonding Strength according to Composition of Ni-Cr alloy for Porcelain Fused to Metal Crown)

  • 김갑진;정인성;최성민
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.113-120
    • /
    • 2013
  • Purpose: This study was to observe surface property and bonding strength according to composition of Ni-Cr alloy for porcelain fused to metal crown. The two kinds of Ni-Cr alloy with different composition ratio of parent metal were observed general properties and chemical properties of each alloy surface and measured the shear bonding strength between ceramic and each alloys. The aim of study was to suggest the material for design of parent metal's composition ratio to development of alloy for porcelain fused to metal crown. Methods: The two kinds of alloy as test specimen was Ni(71wt.%)-Cr(12wt.%) and Ni(63wt.%)-Cr(23wt.%) alloy. The oxide on surface was observed by SEM and EDX. And the shear test was performed by MTS. Results: The surface property and oxide characteristic analysis of oxide layer, weight percentage of Element O within $Ni_{71}Cr_{12}$ alloy measured 12.74wt.%, but $Ni_{63}Cr_{23}$ alloy was measured 15.91wt.%. And the maximum shear bonding strength was measured 106.14MPa between $Ni_{71}Cr_{12}$ alloy and vintage halo (VV group). Conclusion: The surface property and oxide characteristic of $Ni_{71}Cr_{12}$ alloy was similar to $Ni_{63}Cr_{23}$ alloy. And VV group has the strongest shear bonding strength.

금속-도재관용 Ni-Cr 합금의 표면산화물특성에 따른 전단결합강도 관찰 (Shear Bonding Strength by the Characteristic of Metal Oxidation on the Surface of Ni-Cr Alloy for Porcelain Fused Metal Crown)

  • 정인성;김치영
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.359-364
    • /
    • 2013
  • Purpose: This study was to observe characteristic of metal oxidation and bonding strength according to composition of Ni-Cr alloy for porcelain fused to metal crown. The three kinds of Ni-Cr alloy with different composition ratio of parent metal were observed general properties and chemical properties of each alloy surface and measured the shear bonding strength between ceramic and each alloys. The aim of study was to suggest the material for design of parent metal's composition ratio to development of alloy for porcelain fused to metal crown. Methods: The three kinds of alloy as test specimen was Ni(59wt%)-Cr(24wt%), Ni(67wt.%)-Cr(16wt.%) alloy and Ni(71wt%)-Cr(12wt%)alloy. The oxide on surface was observed by EDX. And the shear test was performed by MTS. Results: The surface property and oxide characteristic analysis of oxide layer, weight percentage of Element O within $Ni_{59}Cr_{24}$ alloy measured 23.03wt%, $Ni_{67}Cr_{16}$ alloy measured 21.13wt% and $Ni_{71}Cr_{12}$ alloy was measured 48.55wt%. And the maximum shear bonding strength was measured 58.02Mpa between $Ni_{59}Cr_{24}$ alloy and vintage halo(H2 group). Conclusion: The surface property and oxide characteristic three kind of Ni-Cr alloy was similar. and shear bonding strength showed the highest bonding strength in H2 specimens.

도재소부용 금합금에서 인듐, 주석 첨가가 금속-도재계면 특성에 미치는 영향 (Effects of Indium and Tin on Interfacial Property of Porcelain Fused to Low Gold Alloys)

  • 남상용;곽동주;정석민
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.31-43
    • /
    • 2001
  • This study was performed to observe the micro-structure change of surface, behavior of oxide change of element, the component transformation of the alloy and the bonding strength between the porcelain interface in order to investigate effects of indium, tin on interfacial properties of porcelain fused to low gold alloy. Hardness of castings was measured with a micro-Vicker's hardness tester. The compositional change of the surface of heat-treated specimen was analyzed with an EDS and an EPMA. The interfacial shear bonding strength between alloy specimen and fused porcelain was measured with a mechanical testing system(MTS 858.20). The results were as follows: 1) The hardness value of alloy increased as increasing amount of indium addition. 2) The formation of oxidation increased as increasing indium and tin contents after heat treatment. 3) Diffusion of indium and tin elements increased as increasing indium and tin contents in metal-porcelain surface after porcelain fused to metal firing. 4) The most interfacial shear bonding strength was increased as increasing a composition of adding elements, and a heat-treatment time, and an oxygen partial pressure. From the results of this study it was found that the addition of alloying elements such as indium and tin increase hardness of as-cast alloy, produce surface oxide layer of adding elements by heat-treatment which may improve interfacial bonding strength between alloy and porcelain.

  • PDF

치과기공사들의 건강관리 실태 및 인식수준에 관한 조사 연구 (A Study on the Health Management of Dental Technicians and Their Awareness of the Same)

  • 최운재
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.113-128
    • /
    • 2000
  • The purpose of this study was to serve as a basis for the development of dental technology and for creating a condition that dental technicians could work with pride and right values, by examining what problems there were in their health care, what they thought about them, and how the problems could be solved, The findings of this study were as below: 1. The most serious and harmful element in dental technology workshop was a dust(57.5%) and a noise(33.3%). 2. Approximately 99.0% of the dental technicians investigated made a complain of air pollution caused by noise. Their opinion on a possible measure to remove noise air pollution was that the noise-generating machine should be replaced(64.1%) or that it should be isolated(28.8%). 3. 76.0% complained air pollution cause by dust deteriorates their working efficiency. As a way to eliminate it, they suggested a dust chamber(35.3%) or an air cleaner(27.5%) should be installde. 4. About 80% made a complain of gas air pollution. The most common related symptom was a headache(56.9%). They thought that gas-generating machine should be isolated(39.9%) or that an air purifier should be prepared(33.3%). 5. The largest impact of heat and light on their body was weakening their eyesight(56.9%). 47.1% got burn once though four times, and 34.3% did five times or more. The way to prevent them was to install an automatic casting machine(66.0%) or use protective glasses(28.1%). 6. Approximately 47.7% were considering a change of occupation, and the most common reason was heavy work(23.5%), followed by poor prospect(21.6%) and working environment(19.0%) in the order named. 7. 88.9% responded they were likely to have an occupational disease. Their idea about the proper frequency of regular health examination was once a year(53.6%), or once per every six months(41.8%). 8. The field they were most interested in was health care(39.2%), followed by academic research activities(31.4%). This fact indicated it's most urgently required to improve their working environment.

  • PDF

Rocatec system이 Zir-ceram과 간접복합수지간의 전단결합강도에 미치는 영향 (Effect of Rocatec system on Shear Bond Strength between Zir-Ceram and Sinfony Indirect Composite Resin)

  • 김동일;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.23-29
    • /
    • 2008
  • The purpose of this study is to evaluate possibility of using indirect composite resin instead of porcelain through the measurement of shear bond strength between zirconia core and indirect composite resin under treatment of $Rocatec^{TM}$ system for improving the adhesion of indirect composite resin. 20 cylindrical zirconia core specimens were divided into 2 groups, according to zirconia surface treatment and attached materials: 1) treated with sandblast and attached with indirect composite resin, 2) treated with sandblast + $Rocatec^{TM}$ system and attached with indirect composite resin. The shear bond strength of each experimental group was measured by MTS and the changes of zirconia core surface according to surface treatments were obtained by SEM observation and measurements of surface roughness. The mean shear bond strength values are $0.55\;{\pm}\;0.11MPa$(Group SC) and $1.16\;{\pm}\;0.46MPa$(Group SRC). The mean Ra values for the surface treatments were follows: $0.39\;{\pm}\;0.13$($100{\beta}_{{\mu}m}$ sandblast) and $0.50\;{\pm}\;0.03$($100{\beta}_{{\mu}m}$ sandblast + $Rocatec^{TM}$ system). In the analysis of EDS, Si element was detected in the Group SC. The shear bond strength between zirconia core and indirect composite resin was improved significantly by using $Rocatec^{TM}$ system.

  • PDF