• 제목/요약/키워드: and low power simulation

검색결과 2,121건 처리시간 0.035초

IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰 (Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364)

  • 김두웅;류규상;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

Space-Time Characteristics of the Wall Shear-Stress Fluctuations in an Axial Turbulent Boundary Layer with Transverse Curvature

  • Shin, Dong-Shin;Lee, Seung-Bae;Na, Yang
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1682-1691
    • /
    • 2005
  • Direct numerical simulation database of an axial turbulent boundary layer is used to compute frequency and wave number spectra of the wall shear-stress fluctuations in a low-Reynolds number axial turbulent boundary layer. One-dimensional and two-dimensional power spectra of flow variables are calculated and compared. At low wave numbers and frequencies, the power of streamwise shear stress is larger than that of spanwise shear stress, while the powers of both stresses are almost the same at high wave numbers and frequencies. The frequency/streamwise wave number spectra of the wall flow variables show that large-scale fluctuations to the rms value is largest for the stream wise shear stress, while that of small-scale fluctuations to the rms value is largest for pressure. In the two-point auto-correlations, negative correlation occurs in streamwise separations for pressure, and in span wise correlation for both shear stresses.

풍력발전용 농형유도발전기의 최대출력제어 (Maximum Output Control of Cage-Type Induction Generator for Wind Power Generation)

  • 구성영;이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.288-292
    • /
    • 2001
  • In this paper, a maximum power control of a low-cost and rugged cage-type induction generator system is proposed, where the machine-side PWM converter is used for maximum power generation and field excitation control, and the line-side PWM inverter is used for the dc link voltage control and source-side power factor control. Simulation results through Matlab Simulink have been demonstrated.

  • PDF

진동 에너지 하베스팅 자원을 위한 저전력 MPPT 인터페이스 (Low-Power MPPT Interface for Vibration Energy Harvesting Sources)

  • 송수민;김현철;이은경;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.39-42
    • /
    • 2018
  • 본 논문에서는 진동 에너지 수확을 위한 MPPT 제어기능을 갖는 인터페이스 회로를 설계하였다. 설계된 회로는 수확된 교류 형태의 에너지를 시스템 구동에 필요한 직류 형태의 에너지로 정류하고, MPPT Controller를 통해 Open Circuit Voltage(Voc)를 주기적으로 샘플/홀드한 뒤, 입력전압을 최대 가용 전력점의 1/2되는 전압으로 유지시키면서, 수확된 전력을 부하에 전달하는 동작을 한다. 모든 회로들은 0.35-um CMOS 기술을 기반으로 설계되었으며, 모의실험을 통하여 동작을 검증하였다. 모의실험 결과 설계된 회로는 3V 입력전압에서 98nA의 전류를 소모하며, 최대 전력효율은 99.21%이다. 설계된 회로의 칩 면적은 $1.281mm{\times}1.236mm$ 이다.

  • PDF

고전압 입력용 SMPS의 고효율 전략 (High Efficiency Strategy of High Input Voltage SMPS)

  • 우동영;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.365-371
    • /
    • 2019
  • Recently, the demonstration and research on the power transmission using high voltage DC such as HVDC(High Voltage DC), Smart Grid, DC transmission and distribution have been actively conducted. In order to control the power converter in high-voltage DC power transmission system, SMPS(Switching Modulation Power Supply) for power converter control using high-voltage DC input is essential. However, the demand for high-pressure SMPS is still low, so the development is not enough. In the low-output SMPS using the high-voltage input, it is difficult to achieve high efficiency due to the switching transient loss especially at light load. In this paper, we propose a new switching scheme for high power SMPS control for low output power. The proposed method can provide better efficiency increase effect in the light load region compared to the existing PWM method. To verify the feasibility of the proposed method, a 40 W SMPS for HVDC MMC(Modulation Multi-level Converter) was designed and verified by simulation.

Analytical Model of Double Gate MOSFET for High Sensitivity Low Power Photosensor

  • Gautam, Rajni;Saxena, Manoj;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권5호
    • /
    • pp.500-510
    • /
    • 2013
  • In this paper, a high-sensitivity low power photodetector using double gate (DG) MOSFET is proposed for the first time using change in subthreshold current under illumination as the sensitivity parameter. An analytical model for optically controlled double gate (DG) MOSFET under illumination is developed to demonstrate that it can be used as high sensitivity photodetector and simulation results are used to validate the analytical results. Sensitivity of the device is compared with conventional bulk MOSFET and results show that DG MOSFET has higher sensitivity over bulk MOSFET due to much lower dark current obtained in DG MOSFET because of its effective gate control. Impact of the silicon film thickness and gate stack engineering is also studied on sensitivity.

Implementation of PDP Driving Circuit for AC-Type

  • Jang, Yun-Seok;Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제5권3호
    • /
    • pp.285-288
    • /
    • 2007
  • PDP(Plasma Display Panel) driving circuit requires switching devices and capacitors to stand up high voltages over 150volts. Thereby the power consumption and the cost of a PDP driving circuit increase. In this paper, a PDP driving circuit is proposed that can be operated with a lower supply voltage than the supply voltage of conventional driving circuit. The operation of the proposed driving circuit is verified by the computer simulation and experiments. PSPICE simulation and experiments results show that the output signal can drive PDP cells when the supply voltage is higher than 40volts.

Design of a Low-Order Sensorless Controller by Robust H∞ Control for Boost Converters

  • Li, Xutao;Chen, Minjie;Shinohara, Hirofumi;Yoshihara, Tsutomu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1025-1035
    • /
    • 2016
  • Luenberger observer (LO)-based sensorless multi-loop control of a converter requires an iterative trial-and-error design process, considering that many parameters should be determined, and loop gains are indirectly related to the closed-loop characteristics. Robust H∞ control adopts a compact sensorless controller. The algebraic Riccati equation (ARE)-based and linear matrix inequality (LMI)-based H∞ approaches need an exhaustive procedure, particularly for a low-order controller. Therefore, in this study, a novel robust H∞ synthesis approach is proposed to design a low-order sensorless controller for boost converters, which need not solve any ARE or LMI, and to parameterize the controller by an adjustable parameter behaving like a "knob" on the closed-loop characteristics. Simulation results show the straightforward closed-loop characteristics evaluation and better dynamic performance by the proposed H∞ approach, compared with the LO-based sensorless multi-loop control. Practical experiments on a digital processor confirmed the simulation results.

저전력 D-flipflop을 이용한 고성능 Dual-Modulus Prescaler (High Performance Dual-Modulus Prescaler with Low Power D-flipflops)

  • 민경철
    • 한국통신학회논문지
    • /
    • 제25권10A호
    • /
    • pp.1582-1589
    • /
    • 2000
  • 본 논문에서는 GHz 대역에서 동작하며 소모전력이 적은 동적 D-flipflop을 제안한다. 제안하는 D-flipflop은 두 가지 측면의 장점을 제공한다. 첫째, 클럭 입력을 갖는 PMOS 트랜지스터의 개수를 줄여 기존회로와 동일한 면적하에서도 고속 동작을 할 수 있다. 둘째, 클럭 업력을 갖는 NMOS 트랜지스터 공유에 의하여 glitch를 줄이고 소모전력을 낮출 수 있다. 제안하는 D-flipflop의 성능 비교를 위하여 기존회로와 동일한 면적의 레이아웃 회로에서 소모전력 및 최대동작주파수의 측정실험을 한다. 제안하는 회로의 응용 예로 고속 prescaler에서 동일한 방법의 특성실험을 한다. 성능분석결과 기존 회로에 비하여 동작속도와 전력소모 측면에서 우수한 성능을 나타냄을 확인하였다.

  • PDF

낮은 저항의 IH 전용용기를 가열할 수 있는 유도 가열 컨버터와 코일 설계 (Design Methodology of Series Resonant Converter and Coil of Induction Heating Applications for Heating Low Resistance IH-Only Container)

  • 정시훈;박화평;정지훈
    • 전력전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.24-31
    • /
    • 2018
  • An induction heating (IH) resonant converter, as well as its coil design method, is proposed in this study to improve the heat capability of low- and high-resistance IH vessels. Conventional IH resonant converters have been designed only for heating high-resistance containers designed for IH application. Thus, the primary current in the resonant tank becomes extremely high to transfer the rated power when the converter heats the low-resistance vessel. As a result, the rated power cannot be transferred due to overcurrent flows against the rated switch current. Hence, the optimal number of coil turns and proper operating frequency to heat high- and low-resistance vessels are proposed in this study by analyzing an IH load model. Simulation and experimental results using a 2.4 kW prototype resonant converter and its IH coil validate the proposed design.