• Title/Summary/Keyword: alkalinity

Search Result 480, Processing Time 0.022 seconds

Studies on the alkalinity of pharmaceutical containers (의약품에 사용되는 유리용기의 용출알카리도에 대하여)

  • 김상민;이규송
    • YAKHAK HOEJI
    • /
    • v.12 no.1_2
    • /
    • pp.35-39
    • /
    • 1968
  • Alkalinity of pharmaceutical containers is to be highly influenced for liquid pharmaceuticals. The criteria of the alkalinity of ampoules and vials used as pharmaceutical containers is established in the Korean Pharmacopoeia. However, the criteria of general containers for liquid pharmaceuticals is not eatablished in the Korean Pharmacopoeia. Therefore, we tried to perform comparing test for domestic products and foreign products of following group: 1) vials 2) general containers for liquid pharmaceutical 3) general containers for tablet pharmaceuticals It was found that the domestically produced vials were good enough for criteria, while almost fifty percent of non-established containers was unsaticefactory.

  • PDF

To Experimental Study of Alkalinity Recovery Agent application in field (알칼리회복제의 현장 적용성에 관한 실험적 연구)

  • 김광기;박선길;김우재;이영도;송병창;정상진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.7-10
    • /
    • 2002
  • Concrete used up to date semipermanent architecture material but now day concrete early deterioration emboss social issue because of construction structure and environmental factor. so, many study of deterioration concrete construction improve durability used impregnation alkalization agent. In These to Study of derelop reoairmeat material in reduce carbonation. xoncrete Building use Alkalinity Recovery Agent which is Realkalinity and strength surface. Alkalinity Recovery Agent undisposed application volume and cure the concrete period. To study Alkalinity Recovery Ahent spray and cure the concrete propriery in field.

  • PDF

Effects of pH, Alkalinity and Chloride on Release of Corrosion By-product in Copper Pipes (pH, 알칼리도, 염소이온이 동관의 부식 부산물 용출에 미치는 영향)

  • 김선일;곽필재;이운기;우달식;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.75-83
    • /
    • 1999
  • In this research, the has been speculation about effects of pH, alkalinity, and chloride, each of which are major factors in water for the corrosion of copper pipes frequently used as the distribution system throughout the world. It is believed that these factors release a corrosion by-product. The results show the following that the first, for each water sample of pH 7, 8 and 9, various concentrations of alkalinity at 10, 50, 100, 150 mg/L was tested. It was found that conditions of higher pH led to decreased concentrations of copper by-product. For each pH, higher alkalinity produced higher concentrations of copper by-product. the second, higher chloride concentrations led to decreased concentrations of copper by-product. Apparently this was due to the Nantokite(CuCl) formation on the inner walls of the copper pipes with the passage of time. The third, when 25, 50mg/L of chloride were added, the average decreasing rate of copper release concentration was 45.7, 66.7%, respectively.

  • PDF

Analysis of Construction Condition and Environmental Effect of Deep Soil Mixing (심층혼합처리 공법의 시공조건 및 환경적 영향 분석)

  • Cho, Jin-Woo;Lee, Yong-Soo;Yu, Jun;Shin, Won-Jae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1155-1158
    • /
    • 2006
  • This paper presents a study on the construction condition and environmental effect of deep soil mixing. Construction condition means the difference in unconfined compressive strength with respect to the depth and location of samples. Environmental effect means alkalinity diffused from soil stabilizer. The experimental results indicate that the unconfined compressive strength vary with respect to the depth, and doesn't show consistency pattern. So, in field application we must decide a mixing ratio enough to satisfy the least unconfined compressive strength. The difference in unconfined compressive strength with respect to the location of samples is negligible. The generation of alkalinity from soil stabilizer is reduced by permeating in non-improved soil and it is expected that the diffusion of alkalinity has no environmental effect on soil and ground water.

  • PDF

Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion (동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향)

  • Jo, Kwan-Hyung;Kim, Sun-Il;Woo, Dal-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

Application of Accelerated Carbonation Reaction for Low Alkalinity of Recycled Aggregate

  • Lee, Jong-Chan;Lee, Sae-Hyun;Yoon, Sang-Hyuck;Song, Tae-Hyeob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.515-522
    • /
    • 2011
  • As Construction and Demolition (C&D) debris increases every year, systems have been adopted to compel the use of recycled aggregate made from C&D debris, and the use of recycled aggregate in the construction field has increased. But environmental problems linked to the alkalinity of recycled aggregate have occurred, and a study on approaches to lower the alkalinity of recycled aggregate is needed. It was certified by this study that a large amount of recycled aggregate could be carbonated in the C&D debris midterm-treatment field. As a result, the density and the water absorption of recycled aggregate after carbonation reaction was improved, and pH of recycled aggregate was lowered from over 11 to 9.4. X-ray Diffraction (XRD), Scanning Electron Microscope (SEM), Energy Dispersive Spectroscopy (EDS), and Thermogravimetry/Differential Thermal Analysis (TG/DTA) methods also indicated the carbonation of recycled aggregate.

A Study on the Optimization of Recycled Aggregate Alkalinity Reducing Facility in the Field (순환골재 알카리 저감장치의 현장 최적화에 관한 연구)

  • Lee, Jong-Chan;Song, Tae-Hyeob;Lee, Sae-Hyun;Kim, Jong-Bok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.53-60
    • /
    • 2011
  • As Construction & Demolition(C&D) debris increase every year, a system has enforced for recycled aggregate made out of C&D debris, then recycled aggregate usage increased in construction field. But as environmental problem by alkalinity of recycled aggregate occurred, the study for lowering alkalinity of recycled aggregate is needed. In this study we made alkalinity reducing facility and installed in the C&D debris midterm-treat field. Then we certified effect of lowering alkalinity and quality of recycled aggregates before and after carbonation. As a result, the most effective carbonation condition is 30seconds in carbonation time, -50~100 kPa of reaction pressure with change of 3cycles. This condition made pH 9.33~9.8 of recycled aggregate possible. The quality of recycled aggregate after carbonation was better than before carbonation in terms of plasticity index, modified CBR, abrasion loss, sand equivalent, liquid limit, size distribution, density and water absorption.

  • PDF

Parameters Affecting Nitrite Accumulation in Submerged Biofilm Reactor (생물막 반응기에서 아질산성 질소의 축척에 미치는 영향인자)

  • Hwang, Byung-Ho;Hwang, Kyung-Yub;Choi, Eui-So
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1789-1797
    • /
    • 2000
  • The objective of this study was to assess parameters affecting nitrite accumulation, which offers advantages in terms of less aeration energy and carbon consumption for denitrification. The influence of the alkalinity to $NH_4{^+}-N$ concentration ratio, pH, FA(free ammonia) concentration and temperature on nitrite accumulation was investigated. The experiment was performed with supernatant from dewatering process of anaerobic digested sludge using a submerged biofilm reactor. The influent contains high strength of ammonium nitrogen and the alkalinity was insufficient for complete nitrification. An increased nitrite accumulation was observed with increase in alkalinity to $NH_4{^+}-N$ concentration ratio. The increase in alkalinity to $NH_4{^+}-N$ concentration ratio has been a maior reason for the high pH value and FA concentration in the reactor. It can be considered that selective inhibition of Nitrobacter can be causes of nitrite accumulation. The nitrite accumulation increased with increment of temperature at fixed alkalinity to $NH_4{^+}-N$ concentration ratio.

  • PDF

Study on characteristic for Larson's ratio of water treatment plants (국내 정수장의 Larson's ratio 특성에 관한 연구)

  • Min, Byung-dae;Chung, Hyen-mi;Ahn, Kyung-hee;Park, Ju-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.579-586
    • /
    • 2016
  • In many countries in order to manage corrosion of water treatment process, it is currently using Langelier index (LI). However, management of the Larson's ratio (LR) to compare corrosion management and LI which can be generated by the water treatment process is required. In this study, in order to ensure data LR, factors associated with the actual corrosion resistance of water treatment plant was measured. Using the measured data, the model equation can be estimated alkalinity, and using the statutory water quality data, LR and alkalinity is estimated. At comparison of the measured value and estimated value of alkalinity, it appeared in $R^2$ = 0.629, using the statutory water quality data and estimated alkalinity model, LR and alkalinity (Whole water treatment plants : 472) is estimated. Concentration of estimated alkalinity is 0.5 mg/L to 107.5 mg/L (average : 23.2 mg/L), and LR is 0.1 to 10 (average : 1.3). At tendency to corrosion of investigated LR, "No metal tendency" (>0.5) is 39 water treatment plants, 8.26 %, and "corrosion metal tendency" is 433 water treatment plants, 91.74%.

Effect of the Physical Parameters and Alkalinity in the Ammonia Stripping (반응조의 물리적 인자와 알칼리도가 암모니아 탈기에 미치는 영향에 관한 연구)

  • An, Ju-Suk;Lim, Ji-Hye;Back, Ye-Ji;Chung, Tae-Young;Chung, Hyung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.8
    • /
    • pp.583-590
    • /
    • 2011
  • The effect of the physical parameters in the reactor (aeration depth, bubble size, and surface area) and the alkalinity of the solution on the ammonia stripping by bubbling were evaluated. When an airflow of 30 L/min was bubbled below the solution surface in the range 6-53 cm, the ammonia removal rate were observed to be the same regardless of the bubbling depths. At pH 10.0 and a temperature of $30^{\circ}C$, the average rate constant and the standard deviation were $0.178h^{-1}$ and 0.004. No appreciable changes in the ammonia removal rate were also observed with varying the bubble size and the air-contacting surface area. Alkalinity of the solution was found to affect the ammonia removal rate indirectly. This is expected because the pH of the solution would vary with dissolution of gaseous $CO_2$ by air bubbling. The real wastewaters from landfill site and domestic wastewater treatment plant were tested. In the case of domestic wastewater (pH = 7.1, alkalinity = 75 mg/L), the ammonia removal rate was poor even with the control of pH to 9.3. The raw landfill leachate (pH = 8.0, alkalinity = 6,525 mg/L), however, showed the appreciable removal rate with increasing pH during aeration. When the initial pH of the leachate was adjusted 9.4, the removal rate was significantly increased without changing the pH during aeration.