• 제목/요약/키워드: ageing test

검색결과 141건 처리시간 0.024초

송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션 (A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line)

  • 한세원;조한구;우병철;정길조;이동일;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF

고분자(高分子) 강성체(彈性體)의 노화방지제(老化防止劑) 효과(效果)에 관(關)한 연구(硏究) (A Study on the Effect of Rubber-Bound Antioxidant and Ordinary Antioxidant in Elastomer.)

  • 최세영;백남철
    • Elastomers and Composites
    • /
    • 제17권1호
    • /
    • pp.13-21
    • /
    • 1982
  • The purpose of this dissertation is to compare bound andtioxidant, MHPPD with the ordinary one, IPPD, when high polymers are used like NR and SBR. The effect of rubber bound antioxidant and ordinary antioxidant on the Mooney scorch time has been studied by means of the Mooney viscometer. The ageing properties of vulcanizates containing rubber-bound antioxidant and ordinary antioxidant have been studied in terms of hardness, tensile strength and elongation. The results of the Mooney scorch time and ageing properties are as follows: When MHPPD was mixed with NR or SBR compounds, the Mooney scorch time was faster than the IPPD compounds. Also the ageing properties of the vulcanizates containing MHPPD were much superior to the IPPD compounds. Furthermore, the vulcanizates comporised of MHPPD have taken andvantage of and resistance in the ozone test.

  • PDF

고압전동기 고정자권선의 부분방전 특징추출 (Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor)

  • 박재준;김희동;이동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.112-116
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet transform coefficients.

  • PDF

열처리한 A5082와 A6060합금의 인장특성에 미치는 변형율속도 및 예비변형율의 영향 (Effect of Strain Rate and Pre-strain on Tensile Properties of Heat-treated A5082 and A6060 Aluminium Wrought Alloys)

  • 이충도
    • 열처리공학회지
    • /
    • 제33권4호
    • /
    • pp.161-172
    • /
    • 2020
  • The tensile property of A5082 and A6060 aluminium wrought alloys was investigated, in terms of the strain rate sensitivity on alloy conditions by heat treatment and bake hardenability on pre-strain prior to strain ageing. The tensile test was carried out in a range of strain rate of 4.17 × 10-5 s-1 ~ 4.17 × 10-5 s-1 in room temperature and the nominal range of pre-strain was 3.0 ~ 10.5%. The tensile deformation of A5082 alloys is characterized as typical case of dynamic strain ageing with negative strain rate sensitivity for all conditions, and the tensile strength indicates a similar level regardless of alloy conditions, except only in full annealed condition. The stress-relief annealing on A6060 alloys can induce practical decrease in strength level of over approximately 100 MPa without any ductility loss, compared to as-rolled condition, while a full annealed and aged condition leads remarkable strengthening effect with the decrease of tensile elongation. Additionally, the bake hardenability of A5082 alloy by strain ageing indicates a negative dependence upon the increase of pre-strain, while A6060 alloy exhibits a positive sign even in low level relatively compared with conventional SPCC.

Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • 장혁진;양종경;이종찬;김우영;신익태;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.219-219
    • /
    • 2009
  • ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.

  • PDF

The Structural and Electrochemical Properties of Thermally Aged Li[Co0.1Ni0.15Li0.2Mn0.55]O2 Cathodes

  • Park, Yong-Joon;Lee, Ju-Wook;Lee, Young-Gi;Kim, Kwang-Man;Kang, Man-Gu;Lee, Young-Il
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2226-2230
    • /
    • 2007
  • As a cathode material of lithium rechargeable batteries, charged Li[Co0.1Ni0.15Li0.2Mn0.55]O2 electrodes, which were aged thermally at 25 oC and 90 oC respectively, were characterized by means of charge/discharger, impedance spectroscopy, and X-ray diffraction. The discharge capacity diminution of the electrodes aged at 25 oC and 90 oC for 1 week was 4% and 23%, respectively. The cell aged at 25 oC was recovered on cycling. However, the capacity loss after ageing at 90 oC was not recovered in a subsequent cycling test, which demonstrates that the reaction occurring during ageing at 90 oC is irreversible. A significant impedance increase of aged electrode at 90 oC is associated with irreversible capacity loss. The structural changes including phase transformation were not detected by XRD analysis, because it could be due to out of detection limit. After ageing, impedance was slightly decreased during subsequent cycling test. It could be explained the cyclic performance of aged sample is stable. The thermal stability was not deteriorated by ageing even at the high temperature of 90 oC.

HFPD 및 신경회로망을 이용한 고압 유도전동기 모델코일 열화진단 (Aging Diagnosis of Model Coil of HV Induction Motor Using HFPD and Neural Networks)

  • 김덕근;임장섭;여인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.361-367
    • /
    • 2002
  • Many failures in high voltage equipment are preceded by partial discharge activity. In this paper deals with the application of the high frequency partial discharge measurement technique in motorette. HFPD measurement is very effective method to detect the PD occurred in motorette which is the called name of test specimen for accelerating test of stator winding[1] In this study, CT type HFPD sensor is used to detect the partial discharges and a measured HFPD pattern is analyzed by fractal mathematics. The neural network algorithm is used to pattern recognition and ageing diagnosis. As a result of this study, the fractal dimensions are increased along to applied voltage and HFPD pattern recognition using neural network shown excellent recognition rate. Also, the ageing diagnosis of motorette has been Possible.

온도퓨즈 노화시험설비 자동화시스템 개발 (Development of remote control and monitoring system for ageing test chamber of thermal-links)

  • 김근용;류재남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.973-974
    • /
    • 2007
  • 최근 전기용품 안전기준(이하 K 기준)의 국제규격(이하 IEC 규격) 부합화에 따라 온도퓨즈(thermal-links)에 대한 노화시험(ageing test)이 중요한 성능평가항목으로 부각되고 있다. 특히, 50일 이상 소요되는 온도퓨즈의 노화시험을 하기 위해서는 규격에 적합한 온도상승률을 가지고, 용단시간 및 용단온도를 정확하게 측정할 수 있는 시스템이 구축되어야 하므로, 그 성능평가설비 또한 매우 중요하다고 할 수 있다. 본 논문에서는 온도퓨즈의 K 기준 및 IEC 규격을 분석하여 노화시험항목을 고찰하였으며, 온도퓨즈 노화시험설비 자동화시스템을 개발하여 국제적 수준의 성능평가기술 기반을 구축하였다. 이러한, 시험설비의 자동화시스템 개발은 성능평가기술을 향상시킬 뿐만 아니라 향후 시험기관의 국제적 위상 제고(提高)에 중요한 역할을 할 것으로 기대된다.

  • PDF

자동차 냉각기 호스용 고무의 전기화학적 복합노화시험 (An Electro-chemical Combined-stress Degradation Test of Rubber for Automotive Radiator Hoses)

  • 곽승범;서부석;최낙삼
    • 한국자동차공학회논문집
    • /
    • 제19권4호
    • /
    • pp.107-113
    • /
    • 2011
  • Coolant rubber hoses for automotive radiators under thermal and mechanical loadings can be degraded and thus failed due to the influences of the locally formed electricity. In this study, an advanced test method was developed to simulate the failure problem of the rubber hose. For carbon black filled EPDM (ethylene-propylene dine monomer) rubber used as a radiator hose material the ageing behaviors by the electro-chemical stresses combined with a tensile strain were analyzed. As the tensile strain increased, the current of the rubber specimen reduced indicating an increase of the internal defects and electrical resistance of the rubber specimen. Elongation at break and IRHD hardness rapidly decreased with increasing the ageing time. Both electro-chemical stress and mechanical tensile stress clearly accelerated the degradation of EPDM rubber.

Testing NBUCA Class of Life Distribution Using U-Test

  • Al-Nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • 제8권2호
    • /
    • pp.125-135
    • /
    • 2007
  • In this paper, testing exponentiality against new better than used in convex average and denote by (NBUCA), or its dual (NWUCA) is investigated through the U-test. The percentiles of these tests are tabulated for samples sizes n = 5(1)40. The power estimates of the test are simulated for some commonly used distributions in reliability. Pitman's asymptotic efficiency of the test is calculated and compared. Data of 40 patients suffering from blood cancer disease (Leukemia) is considered as a practical application of the proposed test in the medical sciences.

  • PDF