Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • 장혁진 (원광대학교 공과대학 광전자응용연구실) ;
  • 양종경 (원광대학교 공과대학 광전자응용연구실) ;
  • 이종찬 ((주)금호전기 기술연구소) ;
  • 김우영 (원광대학교 공과대학 광전자응용연구실) ;
  • 신익태 (원광대학교 공과대학 광전자응용연구실) ;
  • 박대희 (원광대학교 공과대학 광전자응용연구실)
  • Published : 2009.11.12

Abstract

ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.