• Title/Summary/Keyword: aes

Search Result 1,426, Processing Time 0.022 seconds

The Efficient AES-CCM Architecture for a hardware library in the WAVE (WAVE 하드웨어 암호 라이브러리에 적합한 효율적인 AES-CCM 구조 설계)

  • Lee, Yeon-Cheol;Seo, Hwa-Jeong;Kim, Ho-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2899-2905
    • /
    • 2013
  • According to developing wireless communications in vehicle, various security threat in the WAVE(Wireless access in vehicular environments) is increased. To protect this, IEEE 1609.2 specify services as for prevent message from attacks such as spoofing, eavesdropping and replay. It is possible to implement a hardware library for defending these attacks. In this paper, we proposed a efficient AES-CCM architecture for the hardware library in the WAVE. We compare our architecture to the previous one in the same FPGA. And our design uses less slices than 27 % of it and less slices than 45 % of it if we share registers that were used by other modules in the library. We also achieves a throughput of 1355 Gbits/s in xc5vlx110t-2ff1136.

A Design of Authentication/Security Processor IP for Wireless USB (무선 USB 인증/보안용 프로세서 IP 설계)

  • Yang, Hyun-Chang;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2031-2038
    • /
    • 2008
  • A small-area and high-speed authentication/security processor (WUSB_Sec) IP is designed, which performs the 4-way handshake protocol for authentication between host and device, and data encryption/decryption of wireless USB system. The PRF-256 and PRF-64 are implemented by CCM (Counter mode with CBC-MAC) operation, and the CCM is designed with two AES (Advanced Encryption Standard) encryption coles working concurrently for parallel processing of CBC mode and CTR mode operations. The AES core that is an essential block of the WUSB_Sec processor is designed by applying composite field arithmetic on AF$(((2^2)^2)^2)$. Also, S-Box sharing between SubByte block and key scheduler block reduces the gate count by 10%. The designed WUSB_Sec processor has 25,000 gates and the estimated throughput rate is about 480Mbps at 120MHz clock frequency.

Comparison of Adverse Events between High-intensity and Moderate- to Low-intensity Statin Group (의약품부작용보고시스템 데이터베이스를 이용한 고강도 statin과 중·저강도 statin 관련 이상사례 비교 분석)

  • Lee, Sera;Ock, Miyoung;Kim, Hyunah
    • Korean Journal of Clinical Pharmacy
    • /
    • v.28 no.4
    • /
    • pp.293-299
    • /
    • 2018
  • Background: 3-Hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) effectively reduce serum levels of low-density lipoprotein (LDL) and total cholesterol. High-intensity statins are recommended for all patients aged ${\leq}75$ with clinical atherosclerotic cardiovascular disease (ASCVD), diabetes mellitus aged 40-75 with ${\geq}7.5%$ estimated 10-year ASCVD risk and LDL-C ${\geq}190mg/dL$. High-intensity statins associated with more frequent adverse events (AEs) compared to moderate- to low-intensity statins. The aim of this study was to compare AEs between high-intensity and moderate- to low-intensity statin group using the Korea Adverse Event Reporting System (KAERS) database. Methods: Adults (${\geq}18years$) with statin-associated AEs from July 2009-June 2014 were included. Only AEs classified as "certain", "probable" and "possible" based on the WHO-Uppsala Monitoring Center criteria were analyzed. Results: In total, 247 AEs from 196 patients [high-intensity statin group (HG), n = 25 (13%); moderate- to low-intensity statin group (MLG), n = 171 (87%)] were included. Mean age was higher in HG compared with MLG ($67{\pm}14$ vs $62{\pm}12$). The HG showed a significant higher frequency of liver/biliary system disorders (37% vs 14%, p = 0.001). Hepatic function abnormal was reported more frequently in HG compared to MLG (26% vs 9%, p = 0.006). Conclusion: According to KAERS data, liver/biliary system disorders were more frequently reported in HG compared to MLG.

Modified AES having same structure in encryption and decryption (암호와 복호가 동일한 변형 AES)

  • Cho, Gyeong-Yeon;Song, Hong-Bok
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • Feistel and SPN are the two main structures in a block cipher. Feistel is a symmetric structure which has the same structure in encryption and decryption, but SPN is not a symmetric structure. In this paper, we propose a SPN which has a symmetric structure in encryption and decryption. The whole operations of proposed algorithm are composed of the even numbers of N rounds where the first half of them, 1 to N/2 round, applies a right function and the last half of them, (N+1)/2 to N round, employs an inverse function. And a symmetry layer is located in between the right function layer and the inverse function layer. In this paper, AES encryption and decryption function are selected for the right function and the inverse function, respectively. The symmetric layer is composed with simple matrix and round key addition. Due to the simplicity of the symmetric SPN structure in hardware implementation, the proposed modified AES is believed to construct a safe and efficient cipher in Smart Card and RFID environments where electronic chips are built in.

Differential Power Analysis for AES and Countermeasure (AES에 대한 차분전력분석공격과 대응책)

  • 김성진;이동욱;이동익
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1399-1402
    • /
    • 2003
  • Paul Hocker has developed new attacks based on the electric consumption of cryptographic device such as smartcard that performs cryptographic computation. Among those attacks, the Differential Power Analysis(DPA) is one of the most impressive and most difficult to avoid. By analysing the power dissipation of encryption in a device, the secret information inside can be deduced. This paper presents that Advanced Encryption Standard(AES) is highly vulnerable to DPA and readily leaks away all secret keys through the experimental results for DPA. After all, it is required an implementation of the AES algorithm that is not vulnerable to DPA. We also propose countermeasures that employ asynchronous circuit.

  • PDF

A comparative measurement study of Pb, Cd using ICP-AES with different pretreatment methods (ICP-AES를 이용한 전처리방법에 따른 환경시료내 Pb, Cd의 측정 비교 연구)

  • 권태영;윤춘경;전지홍
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.513-520
    • /
    • 1998
  • The evaluation of uncertainty in environmental elemental analysis can be difficult because of the wide variety of analytical sample and objectives. for the specification of measured, elemetal analysis need certain method and high pretreatment technique. The sample of Pb, Cd in paddy soil and sewage sludge were analyzed by same ICP-AES, but each using four different pretreatment technique ; 0.1N HCl extraction, AB-DTPA extraction and two Mixture Acid Digestion. The four technique gave comparable results for the analysis of lead and cadmium. Concentrations determined by Mixture Acid Digestion were more higher than those by 0.1NHCI extraction and AB-DTPA extraction.

  • PDF

Analysis of Grain Boundary Oxidation in $(Ba, Sr)TiO_3$-based PTCR Ceramics by $\mu-AES$ and $DV-X\alpha$ Energy Simulation ($(Ba, Sr)TiO_3$계 PTCR 세라믹스의 입계산화에 대한 $\mu-AES$ 분석 및 $DV-X\alpha$ 궤도에너지 계산모사)

  • 김명철;강영석;허수형;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.6
    • /
    • pp.587-594
    • /
    • 1994
  • (Ba, Sr)TiO3-based PTCR ceramics were sintered and cooled down with various cooling conditions in the air. AES was applied to investigate the composition change in the grain boundary and bulk area of oxidatively cooled samples. Ba component was deficit in grain boundary region, while oxygen was abundant than bulk region. The discrete changes of oxygen binding energies were confirmed in the grain boundary region of the heavily oxidized samples. It was supposed that the large binding energy shift resulted from the oxidation of the segregated Mn in grain boundary region and this idea was supported by the DV-X$\alpha$ molecular energy simulation.

  • PDF

Elemental Analysis of Drinking Water with ICP/AES (ICP/AES에 의한 먹는물의 무기원소 분석)

  • Park, Kye-Hun;Shin, Hyung-Seon;Han, Cheong-Hee
    • Economic and Environmental Geology
    • /
    • v.29 no.1
    • /
    • pp.21-24
    • /
    • 1996
  • Inductively coupled plasma atomic emission spectrophotometer (ICP/AES) is a versatile modern instruments for the multi-element analysis, but quantitative analysis using ICP/AES with normal pneumatic nebulizer is not applicable for the measurement of elemental concentrations in water down to the drinkining water standard level except a few elements because of poor detection limits. However, the detection limit can be lowered enough to measure drinking water standard, if ultrasonic nebulizer and/or hydride vapor generator is attached. This method is tested with groundwater samples from Tajeon area. It is confirmed that the elemental concentrations in these samples are within the limit of drinking water standard for the most elements. However, uranium concentration is very high in some samples compared with the concentrations suggested by Environmental Protection Agency of U.S.A. There is no standard concentration level to this element in Korea and it should be prepared immediately.

  • PDF

The Design and Construction of AES-LEED System and the Study of Ni/Pt(111) System (AES-LEED 장치의 설계 및 제작과 Ni/Pt(111)계에 관한 연구)

  • Lee, Sun-Bo;Bu, Jin-Hyo;Lee, Seong-Yong;Park, Jong-Yun;Gwak, Hyeon-Tae
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.145-151
    • /
    • 1993
  • Ultra High Vacuum chamber for surface analysis and a series of AES-LEED controllers for LEED optics was designed and constructed. Electron energy resolution of LEED optics was tested. On the basis of the layer by layer mode, thickness of evaporated Ni on Pt(111) was calculated from the Auger signal ratio.

  • PDF

AES and XPS Analysis of GaAs Surfaces Sulfurized by $H_2S$ Gas ($H_2S$ 가스로 유황처리된 GaAs 표면의 AES 및 XPS 분석)

  • 신장규;이동근;김항규
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.3
    • /
    • pp.264-268
    • /
    • 1994
  • 본연구에서는 HCl 또는 NH4OH로 산화막을 식각학 GaAs 표면에 H2S 가스를 이용하여 유황처 리하였다. 표면의 화학적 조성 및 결합상태를 측정하기 위하여 AES 및 XPS를 사용하였다. 시편들은 30,200 및 $350^{\circ}C$로 가열하면서 H2S가스와 반응시켰다. 이때 유황은 GaAs 표면의 Ga 원자 및 As 원자 와 화학결합을 형성하고 있음이 밝혀졌다. 또한 $350^{\circ}C$로 가열된 시편이 $30^{\circ}C$ 또는 $200^{\circ}C$로 가열된 시편 보다 표면에 결합된 유황의 양이 많은 것으로 나타났다. 아울러 (NH4)2S 수용액 또는 Na2S 수용액으로 유황처리된 경우와 동일하게 H2S 가스로 유황처리된 GaAs 표면에서는 Ga 산화막 및 As 산화막이 거 의 관측되지 않았다.

  • PDF