• Title/Summary/Keyword: active operation

Search Result 1,488, Processing Time 0.029 seconds

Temporary Closure for Sternotomy in Patient with Massive Transfusion Might Be Lethal

  • Kim, Maru;Kim, Joongsuck;Kim, Sung Jeep;Cho, Hang Joo
    • Journal of Trauma and Injury
    • /
    • v.30 no.1
    • /
    • pp.12-15
    • /
    • 2017
  • A 58-year-old male visited our emergency room for multiple traumas from explosion. On initial evaluation, hemopneumoperitoneum with liver laceration (grade 4) and colon perforation was identified. Hemopericardium with cardiac tamponade was also identified. Shrapnel was detected in the right ventricle. Damage control surgery was planned due to condition of hypotension. In operation room, control over bleeding was achieved after sternotomy, pericardiotomy, and laparotomy. Massive transfusion was done during operation. After gauze packing, operation was terminated with temporary closure (TC). Sanguineous fluid was drained profusely. Disseminated intravascular coagulopathy was confirmed through laboratory findings. No extravasation was discovered at hepatic angiogram. On re-operation, there was no active bleeding but oozing from sternotomy site was identified. Bone bleeding was impossible to control. Finally, reoperation was ended after gauze packing and TC all over again. The patient could survive for only a day after re-operation.

Installation of MFC(Multiple FACTS Coordinated control) On-line System for the Spinning Reserve of a Reactive Power in Metropolitan Area (수도권 순동 무효전력 확보를 위한 FACTS 협조제어 시스템 온라인 설치)

  • Chang, Byung-Hoon;Moon, Seung-Pil;Ha, Yong-Gu;Jeon, Woong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2131-2134
    • /
    • 2010
  • In this paper, the on-line system schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control system of FACTS devices, MFC on-line system calculates the optimal set point(Vref, Qrev) of FACTS devices using the coordinated control algorithm with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. As the test, MFC(Multiple FACTS Coordinated control) on-line system will be installed in Korea power system.

Idle Mode for Deep Power Save in IEEE 802.11 WLANs

  • Jin, Sung-Geun;Han, Kwang-Hun;Choi, Sung-Hyun
    • Journal of Communications and Networks
    • /
    • v.12 no.5
    • /
    • pp.480-491
    • /
    • 2010
  • Along with the wide acceptance of IEEE 802.11 wireless local area network (WLAN), new applications such as Internet protocol (IP) telephony over WLAN are fast emerging today. For battery-powered IP phone devices, the life time extension is a key concern for the market acceptance while today's 802.11 is not optimized for snch an operation. In this paper, we propose a novel idle mode operation, which comprises paging, idle handoff, and delayed handoff. Under the idle mode operation, a mobile host(MH) without any active session does not need to perform handoff within a predefined paging area (PA). Only when it enters a new PA, an idle handoff is performed. The proposed idle mode allows an MH without traffic to extend its life time. We develop a new analytical model in order to comparatively evaluate our proposed scheme. The numerical resnlts demonstrate that the proposed scheme outperforms the existing schemes with respect to power consumption.

Development of Cooperated Control System for Multiple FACTS in KEPCO Power Systems (다기의 FACTS 기기 협조제어 시스템 개발)

  • Chang, Byung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1726-1730
    • /
    • 2008
  • In this paper, the application schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control of FACTS devices, f-V analysis method which is one of the indices for voltage stability was performed with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. In simulation, the SCADA/EMS 2007's data are used for studying the coordinated control algorithm of multiple FACTS devices that is installed or will be installed in KOREA power system

Intelligent Vehicle Management Using Location-Based Control with Dispatching and Geographic Information

  • Kim Dong-Ho;Kim Jin-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.249-252
    • /
    • 2004
  • The automatic determination of vehicle operation status as well as continuous tracking of vehicle location with intelligent management is one of major elements to achieve the goals. Especially, vehicle operation status can only be analyzed in terms of expert experiences with real-time location data with scheduling information. However the scheduling information of individual vehicle is very difficult to be interpreted immediately because there are hundreds of thousand vehicles are run at the same time in the national wide range workplace. In this paper, we propose the location-based knowledge management system(LKMs) using the active trajectory analysis method with routing and scheduling information to cope with the problems. This system uses an inference technology with dispatching and geographic information to generate the logistics knowledge that can be furnished to the manager in the central vehicle monitoring and controlling center.

  • PDF

On the Digital Implementation of the Sigmoid function (시그모이드 함수의 디지털 구현에 관한 연구)

  • 이호선;홍봉화
    • The Journal of Information Technology
    • /
    • v.4 no.3
    • /
    • pp.155-163
    • /
    • 2001
  • In this paper, we implemented sigmoid active function which make it difficult to design of the digital neuron networks. Therefore, we designed of the high speed processing of the sigmoid function in order to digital neural networks. we designed of the MAC(Multiplier and Accumulator) operation unit used residue number system without carry propagation for the high speed operation. we designed of MAC operation unit and sigmoid processing unit are proved that it could run of the high speed. On the simulation, the faster than 4.6ns on the each order, we expected that it adapted to the implementation of the high speed digital neural network.

  • PDF

Suggestion of a New Writer's Guideline to Reduce Human Errors Found in the Emergency Operation Procedures of a Nuclear Power Plant (비상운전절차서 작성과정의 인적오류 저감을 위한 지침서 제안에 관한 연구)

  • Lee, Dhong-Ha;Jang, Tong-Il;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.129-138
    • /
    • 2010
  • Gori-I nuclear power plant has been examining the effectiveness and efficiency of the current emergency operation procedures from human factors viewpoint. Previous study showed that some mistakes that the procedures did not comply with the writers' guidelines. Reviewing the current writers' guidelines for emergency operating procedures revealed that they lack of some important human factors rules such as enumeration of switching conditions and detailed action requirements, definite expression for setup points, description for anticipated results, and recommendation for use of present tense, affirmative sentence and active voice. This study suggested a new classification system for the writers' guideline contents supplementing the deficiencies of the current emergency operation procedure text.

Frequency Dependency of Multi-layer OLED Current Density-voltage Shift and Its Application to Digitally-driven AMOLED

  • Kim, Hyunjong;Kim, Suhwan;Hong, Yongtaek
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.181-184
    • /
    • 2012
  • We report, for the first time, operation frequency dependence of current density-voltage ($J_{OLED}-V_{OLED}$) shift for multi-layer organic light-emitting diodes (OLEDs). When the OLEDs were electrically stressed for 21 hours with 50% duty voltage pulses at 60, 120, 240, and 360 Hz, the JOLED-VOLED shifts were suppressed by half for 360 Hz operation compared with 60 Hz operation, but with little change in emission efficiencies. This frequency dependent $J_{OLED}-V_{OLED}$ shift is believed to be commonly observed for typical multi-layer OLEDs and can be used to further improve lifetime of digitally-driven active-matrix OLED displays.

Production Costing Model Including Hydroelectric Plants in Long-range Generation Expansion Planning (장기전원계획에 있어서 수력운전을 고려한 운전비용 계산모형)

  • 신형섭;박영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.2
    • /
    • pp.73-79
    • /
    • 1987
  • This paper describes a new algorithm to evaluate the production cost for a generation system including energy-limited hydroelectric plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. Hydro operation and pumped storage operation have been dealt with in the previous papers using the concept of peak-shaving operation. In this paper, the hydro problem is solved by using a new version of the gradient projection method that treats the upper / lower bounds of variables saparately and uses a specified initial active constraint set. Accuracy and validity of the algorithm are demonstrated by comparing the result with that of the peak-shaving model.

  • PDF

Operation Scheme for a Wind Farm to Mitigate Output Power Variation

  • Lee, Sung-Eun;Won, Dong-Jun;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.869-875
    • /
    • 2012
  • Because of the nature of wind, the output power of wind turbines fluctuates according to wind speed variation. Therefore, many countries have set up wind-turbine interconnection standards usually named as Grid-Code to regulate the output power of wind farms to improve power system reliability and power quality. This paper proposes three operation modes of wind farms such as maximum power point tracking (MPPT) mode, single wind turbine control mode and wind farm control mode to control the output power of wind turbines as well as overall wind farms. This paper also proposes an operation scheme of wind farm to alleviate power fluctuation of wind farm by choosing the appropriate control mode and coordinating multiple wind turbines in consideration of grid conditions. The performance of the proposed scheme is verified via simulation studies in PSCAD/EMTDC with doubly-fed induction generator (DFIG) based wind turbine models.