• 제목/요약/키워드: acid-etched

검색결과 298건 처리시간 0.021초

염산테트라싸이클린의 적용시간에 따른 특수 가공된 임프란트 표면 변화 (Micromorphometric change of implant surface conditioned with Tetracycline-HCl : HA and Etched surface)

  • 한주영;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.731-744
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, HA-coated surface and dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-HCL solution for ${\frac{1}{2}}$min., 1min., $1{\frac{1}{2}}$min., 2min., and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The etched surfaces showed the honey comb structures. The surface conditioning with tetracycline-HCI didn't influence on its micro-morphology. In conclusion, the detoxification with $50mg/m{\ell}$ tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

김치포장 내부의 이산화탄소 및 산소 제어를 위한 포장 기술 고찰 (Critical review on Active Technologies to Regulate the Levels of Carbon Dioxide and Oxygen for Kimchi Packaging)

  • 정수연;이현규;이정수;유승란
    • 한국식생활문화학회지
    • /
    • 제34권2호
    • /
    • pp.233-239
    • /
    • 2019
  • This paper presents a literature review on the active technologies to regulate the levels of carbon dioxide and oxygen in Kimchi packaging. In this study, laser-etched pouches and $O_2$ scavengers were used for Kimchi packaging, and the efficiency of each packaging technique to regulate the $CO_2$ and $O_2$ levels inside Kimchi packages was investigated. When Kimchi was packaged with a laser-etched pouch, the $CO_2$ concentration in the sample with a high gas transmission rate was less than that in other pouches (p<0.05), and a low $CO_2$ level had little effect on the expansion of the package volume. Kimchi treated with an $O_2$ absorber exhibited a significantly lower (p<0.05) $O_2$ concentration inside the packages relative to the control. A low $O_2$ concentration inside the Kimchi package effectively inhibited the growth of total aerobic bacteria and lactic acid bacteria, as well as yeasts and molds on Kimchi. These results suggest that $O_2$ absorbers have a positive effect on the microbial quality of Kimchi. Therefore, packaging in a laser-etched pouch and the use of an $O_2$ scavenger could provide a novel packaging material for regulating the $CO_2$ and $O_2$ levels during Kimchi packaging.

성견에 식립된 sandblasted and large-grit and acid-etched 임플란트에서 N-acetyl cysteine(NAC)의 탑재가 주위 골형성에 미치는 영향에 대한 선행연구 (The Effect of N-acetyl cysteine (NAC) loading on the bone formation surrounding sandblasted and large-grit and acid-etched implants in the dog: A pilot study)

  • 서재민;김인주;배민수;이정진;안승근
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.77-85
    • /
    • 2020
  • 목적: N-acetyl cysteine (NAC)를 탑재한 sandblasted and large-grit and acid-etched (SLA) 임플란트를 성견에 식립한 후, 조직형태학적 분석을 통하여 NAC가 SLA 임플란트 주위의 초기 골형성에 미치는 영향을 알아보고자 한다. 재료 및 방법: NAC 탑재 여부에 따라 2개의 실험군으로 구성하였으며, SI 군은 NAC를 탑재하지 않은 SLA 임플란트로, NSI 군은 NAC를 탑재한 SLA 임플란트로 설정하였다. 4마리의 성체 비글 견에 두 실험군의 임플란트를 식립하고(각 군당 n = 8) 술 후 3주와 6주에 각각 2마리의 비글 견을 희생하여 식립된 임플란트 매식체와 주위 골 조직을 채취하였다. 조직 표본을 제작하고 조직형태학적 검사를 통해 골-임플란트 접촉률 및 골면적비율을 계산하였다. NAC 탑재 여부에 따른 각 실험군간 골-임플란트 접촉률과 골면적비율의 유의성을 알아보기 위해 독립표본 t검정을 이용한 통계분석을 시행하였다(α = .05). 결과: 3주차의 경우 NAC를 탑재한 SLA 임플란트가 일반 SLA 임플란트보다 약 1.5배 높은 골-임플란트 접촉률을 보였으나 통계적 유의성은 없었다(51.79 vs 35.43%; P = .185). 골면적 비율에서는 NAC를 탑재한 SLA 임플란트가 일반 SLA 임플란트보다 통계적으로 유의성 있게 높은 결과 값을 보였다(45.09 vs 37.57 %; P = .044). 6주차의 경우 골-임플란트 접촉률과 골면적 비율 모두에서 NAC를 탑재한 SLA 임플란트와 일반 SLA 임플란트가 비슷한 결과 값을 보였다(P > .05). 결론: 본 실험의 한계 내에서 NAC는 SLA 임플란트 주위의 초기 골형성에 긍정적인 영향을 미침으로써 임플란트의 골유착기간을 단축시키고 하중 부담시기를 앞당기는 데에 기여할 것이라고 사료된다.

부식시간이 소의 법랑질 부식깊이와 교정용 레진의 전단결합강도에 미치는 영향 (EFFECTS OF VARIOUS ETCHING TIMES ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF AN ORTHODONTIC RESIN TO BOVINE ENAMEL)

  • 김정훈;이기수;박영국
    • 대한치과교정학회지
    • /
    • 제23권1호
    • /
    • pp.75-88
    • /
    • 1993
  • Recent reports indicate that shorter etching times than 60 seconds can be adopted without affecting the bond strength and clinical disadvantages. The purpose of this in vitro study was to compare the shear bone strength and to measure depth of etch at different etching time length. One hundred and eight extracted bovine lower central incisors were embedded each in a tooth cup with cold-cure acrylic resin. The facial surfaces of the teeth were ground wet with 600-, 800-, 1000-, and 1200-grit Sic papers, and finally polished with a water slurry of extrafine silicon carbide powder, washed with tap water, and dried with hot air. Nine groups of nine prepared teeth were etched with a commercial($38\%$ phosphoric acid solution) for 0, 5, 10, 15, 20, 30, 60, 90, and 120 seconds, respectively, rinsed with tap water, and dried with hot air. One conditioned teeth from every group was selected randomly for the scanning electron microscopic examination, and the remaining eight teeth of the groups were used for measuring the push shear bond strength after bonding brackets and immensing them in the $36.5^{\circ}C$ water for 24 hours. Another nine groups of three teeth were used for measuring the depth of etch and surface roughness with a surface profilometer. after pieces of adhesive tape of 3mm inner diameter positioned on the ground enamel surfaces, and etched with the above mentioned. The data obtained form the above expeiments were analysed statistically with one way ANOVA and Dunkan's multiple range test with the $95\%$ confidence level. The results and conclusion of the study were as follows; 1. The results of shear bond strength for the given experimental etching times were not statistically different, but showed the tendency of decreasing shear bone strength after over 60 seconds etching times. 2. On the scanning election microscopic examination, it was observed that the morphological patterns of etched enamel surface for 5 to 20 seconds were similar and consitent, and those for 30 to 120 seconds showed increasing over-etched patterns depending on the length of etching times. 3. The depth of etch was increased almost proportionally by the length of etching times, but it was not associated with the shear bond strength. 4. The surface roughness increased depending on the length of etching times, but it was not associated with the shear bond strength. 5. This experiment indicated that proper etching time with $38\%$ phosphoric acid solution is in the range of 5 to 30 seconds.

  • PDF

고분자 안경 렌즈의 재질별 화학적 식각 반응성 비교 (Comparison of Properties of Polymer Based Glass Lenses by Chemical Etching Reaction)

  • 이정화;노혜란
    • 한국안광학회지
    • /
    • 제17권2호
    • /
    • pp.119-126
    • /
    • 2012
  • 목적: 안경 렌즈 코팅 막을 불화수소산을 이용하여 상온에서 단시간 화학적으로 식각한 뒤 코팅 막과 렌즈 원재료의 변화를 살펴보고자 하였다. 방법: GRAY 70%로 염색된 vinyl ester계 고분자(Lens A)와 thiourethane계 고분자렌즈(Lens B)를 불화수소산을 이용해 5분, 10분 또는 15분 동안 식각한 뒤 재료의 기계적 물성과 하드코팅과 반사방지코팅 등 코팅 막의 손상 정도, 그리고 굴절률 광투과율 등 렌즈의 특성 변화를 관찰하였다. 결과: 두 재료 모두 식각 전과 후의 굴절력에는 큰 변화가 없었지만 반사방지코팅과 하드코팅이 차례로 제거되었고 렌즈 표면에도 손상을 주어 UV 투과율이 증가되었으며 기계적 물성은 소하였다. 화학적 식각으로 인한 렌즈의 물성 변화는 thiourethane계 고분자 렌즈에서 더 크게 나타났다. 결론: 고분자 재료의 특성에 따라 불화수소산에 대한 반응성이 다르기 때문에 식각에 따른 렌즈 자체의 물성 변화가 다르게 나타남을 알 수 있었다.

A simplified etching technique to improve the adhesion of fiber post

  • Majeti, Chandrakanth;Veeramachaneni, Chandrasekhar;Morisetty, Pradeep Kumar;Rao, Saggurti Anitha;Tummala, Muralidhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.295-301
    • /
    • 2014
  • PURPOSE. Numerous methods were used to etch the fiber posts to improve its bonding to root canal dentin. Our aim was to evaluate the efficacy of 37% phosphoric acid in etching fiber posts in comparison with 24% hydrogen peroxide. MATERIALS AND METHODS. Ninety human maxillary central incisors were taken and post space preparation was done. Ninety fiber posts were taken and divided into three groups (n=30) based on the surface treatment they received ($H_3PO_4$, $H_2O_2$, distilled water) and each group was further divided (n=10) based on the time period of application (15 seconds, 30 seconds, 60 seconds). All the posts were luted into canals using Rely X UniCem-2. Each tooth was then sectioned into six slices and subjected to push out test. Data obtained was subjected to statistical analysis at P<.05. The surface topography was evaluated using scanning electron microscopy. RESULTS. Highest bond strength values were noted in 15 seconds etched phosphoric acid group and 60 seconds etched hydrogen peroxide group with no significant difference between two groups. Surface topography revealed complete epoxy layer removal with no damage to its structural integrity in those groups. CONCLUSION. $H_3PO_4$ etching for a period of 15 seconds is an effective alternative in improving the adhesion of fiber post to root dentin.

Retrospective clinical study of an implant with a sandblasted, large-grit, acid-etched surface and internal connection: analysis of short-term success rate and marginal bone loss

  • Lee, Jae-Wang;An, Jun Hyeong;Park, Sang-Hoon;Chong, Jong-Hyon;Kim, Gwang-Seok;Han, JeongJoon;Jung, Seunggon;Kook, Min-suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.42.1-42.7
    • /
    • 2016
  • Background: The purpose of this retrospective study was to evaluate the clinical utility of an implant with a sandblasted, large-grit, acid-etched (SLA) surface and internal connection. Methods: Six patients who received dental implants in the Department of Oral and Maxillofacial Surgery, Chonnam National University Dental Hospital, were analyzed by factors influencing the success rate and marginal bone loss. Factors included patient's age, sex, implant installation site, whether bone graft was done, type of bone graft materials, approaching method if sinus lift was done, and the size of the fixture. In addition, the marginal bone loss was analyzed by using a radiograph. Results: All implants were successful, and the cumulative survival rate was 100 %. Average marginal bone loss of 6 months after the installation was 0.52 mm and 20 months after the functional loading was 1.06 mm. Total marginal bone resorption was 1.58 mm on average. There was no statistically significant difference in mesial and distal marginal bone loss. Conclusions: The short-term clinical success rate of the implant with an SLA surface and internal connection was satisfactory. Moreover, the marginal bone loss was also consistent with the implant success criteria.

Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구 (Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant)

  • 조지호;김수관;문성용;오지수;박진주;정종원;윤대웅;양성수;정미애
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권4호
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.

하악 구치부에서 ITI SLA (Sand-blasted, Large-grit, Acid-etched) 임플란트를 이용한 단일 치아 수복의 후향적 임상 연구 (Retrospective study on ITI SLA (sand-blasted, large-grit, acid-etched) implant for mandibular posterior single tooth replacement)

  • 이승문;채경준;정의원;김창성;최성호;조규성;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.661-671
    • /
    • 2006
  • The purpose of this study was to evaluate cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with ITI SLA (sand-blasted, large-grit, acid-etched) implant system and compare the CSR between first and second molar. The findings from the results were as follows; 1. Total of 158 implants were inserted into 147 patients. 68 patients were males, 79 patients were females and their mean age was 47.8 years. 98 implants were placed in first molar area and 60 implants were placed in second molar area. In terms of diameter, implants with wide diameter over 4.8mm dominated (91.1%). Implants with length over lOmm were used (96.2%). 2, In the two cases, there was a slight transient numbness which recovered within 1-2 months. Nine SynOcta screw type abutments demonstrated screw loosening, There were ten cases of crown fallen-out from decementation. 3. Only one failed out of 158 implants. The CSR was 99.4%. The CSRs for first molar and second molar were 99% and 100%, respectively. From the results, it was concluded that single tooth replacement implant in the mandibular posterior area, might be considered as the effective treatment modality comparable to the conventional crown and bridge.

수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교 (Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant)

  • 임형섭;김수관;오지수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권2호
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.