Correlation of XE-2100, ADVIA-120 and Manual Differential Count and Evaluation of Morphology Flag (자동혈구분석기 XE-2100, ADVIA-120와 Manual Differential Count의 상관성 및 Morphology Flag 평가)

  • Lee, Bum Hee;Byun, Nam Sub;Gee, Myung Suk;Song, Soon Young;You, Seon Woo;Park, Hyo Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • With technological advances in automatic hematology analyzers, primary and screening differential counts of white blood cells (WBC) are done with automatic hematology analyzers. They are using different measurement and analysis principles, so differences in WBC differentials and WBC morphology flag exist. This study was carried out to analyze WBC differential counts and WBC morphology flags comparing them with the manual method. Patient EDTA samples in Vacutainer requested for WBC differentials were analyzed with XE-2100. And those samples with suspect flags messages index over 100 were selected and were analyzed with ADVIA-120. Peripheral blood smear film was subsequently made. Three investigators counted 200 cells each (600 cells) in 111 Wright-Giemsa stained blood films. Between two automatic hematology analyzers, neutrophil, lymphocyte, eosinophil, and monocyte showed good correlations, but basophil had moderate correlation. Among automatic hematology analyzers and manual count, neutrophil, lymphocyte, and eosinophil had good correlations, but monocyte had moderate correlation. XE-2100 had higher monocyte, which was due to atypical lymphocyte and myeloblast. LUC in ADVIA-120 was not due to monocyte in XE-2100. Morphology flagging rates were 146.9% in XE-2100 and was 93.2% in ADVIA-120. Positive predictive values of morphology flag were 58.2% in XE-2100 and 54.4% in ADVIA-120. Flags such as atypical lymphocyte, immature granulocyte, and left shift had higher predictive values and those such as N-RBC, platelets clump, and blast had lower ones. Between automatic hematology analyzers, WBC differentials showed good correlations. Predictive values for morphology flags can be variable with changing criteria. Reviewing criteria for WBC differentials and morphology flags should be established in each laboratory with regards to size of laboratory and patients it serves.

  • PDF

COLOR DIFFERENCE OF THE DENTAL COMPOSITES MEASURED BY DIFFERENT COLOR MEASURING INSTRUMENTS (복합레진 색상의 측정 기기에 따른 차이)

  • Park, Su-Jung;Noh, Eun-Young;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.199-207
    • /
    • 2009
  • The objective of this study was to evaluate the effect of color measuring instrument by measuring the color of dental composite resins. Nine shade light cured composite resin disks were prepared (diameter : 15 mm, thickness : 4 mm). CIE $L^*a^*b^*$ color scale of each disk was measured with 3 different types of spectrophotometer [MiniScan XE plus (Model 4000S, Hunter Lab, USA), CM-3500d (Minolta, Japan) and Specbos 2100 Miniature VIS Reflection spectrometer (Serial No: 319416, JETI Technishe VIS Instrumentic GmbH. Germany)]. Miniscan XE Plus and CM-3500d using identical measuring geometry with different size of viewing aperture. But Specbos 2100 using different measuring geometry. Within the limitation of this study, there were color difference (${\Delta}E^*$) from 2.4 to 7.8 between Miniscan XE Plus and CM-3500d, but $L^*$, $a^*$, $b^*$ values showed the high correlation. However, there were great color difference (${\Delta}E^*$) in the extent of about 20 between instruments with the different measuring geometry. Therefore, color scale measured by color measuring instrument should be used as a relative value rather than an absolute value in the field of dentistry.

Methodology and Case Analysis of the Erroneously High Counts in Automated Hematology Analyzer(XE-2100) using WBC (자동 혈구분석기(XE-2100)를 이용한 WBC 과다측정의 확인방법 및 사례 분석)

  • Cho, Young-Kuk;Dong, Kyung-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.275-285
    • /
    • 2009
  • During an 8 month period from January to August 2007, complete blood count (CBC) samples were taken from various wards and from the outpatient department at Samsung Medical Center. In order to determine whether or not the total white blood cells were over counted, results were obtained from both the 4Diff/channel and the white blood cell channel from the automated blood analysis equipment from S company for comparison. Among patients who were on long term treatments, the number of cases determined to be over counted by comparing the WBC counts during this 8 month period was 25. Clinical chemistry tests were also conducted on the same day on the 25 samples taken. 68% of the patients showed to exceed normal range of aspartate transaminase (AST) and alanine aminotransferase (ALT) indicating abnormal liver function, and the total bilirubin range were also in excess in 60% of the total samples taken. Further clinical information which was obtained from the patients showed 98% of the patients were administered with cefepime which is the 4th generation cephalosporin at the time when the WEC were over counted. It is assumed that a multiple of factors investigated caused the over count of the WEC rather than a single factor.

A study of optical characteristics correlated with low dielectric constant of SiOCH thin films through Ellipsometry (Ellipsometry를 이용한 저 유전 상수를 갖는 SiOCH박막의 광학특성 연구)

  • Park, Yonh-Heon;Hwang, Chang-Su;Kim, Hong-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.198-198
    • /
    • 2010
  • The low-k SiOCH thin films were prepared by CCP-PECVD method using BTMSM(Bis-trimethylsilylmethane) precursors deposited on p-Si wafer. The structural complexity originate the complex refractive constants of the films, and resulted the elliptical polarization of the incident linearly polarized light source of Xe-ramp in the range from 190nm to 2100nm. Phase difference and amplitude ratio between s wave and p wave propagating through SiOCH thin film was studied. After annealing, the amplitude of p wave was reduced more than s wave, and phase difference between p and s wave was also reduced.

  • PDF

Test turnaround Time for Complete Blood Cell Count using Delta and Panic Value Checks and the Q-flag Limit

  • Koo, Bon-Kyung;Ryu, Kwang-Hyun;Lim, Dae-Jin;Cho, Young-Kuk;Kim, Hee-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.2
    • /
    • pp.66-74
    • /
    • 2012
  • Test turnaround time (TAT) is the lead time from reception to reporting. In the complete blood cell count (CBC), 4 units of the XE-2100 (Sysmex Corp., Japan) processed around 80% of quantity, 1 unit of the LH-780 (Beckman-Coulter Incorp., USA) processed around 10% and 1 unit of ADVIA-2120 (Siemens AG, Munich, Germany) processed around 10%. We analyzed the change in the TAT for the CBC for over 7 years, from January of 2005 to December of 2011. The delta check made alterations of delta to WBC, hemoglobin, hematocrit, platelet and metamyelocyte, however, did not made them to band neutrophil, eosinophil, basophil and monocyte. The panic value check made alterations of panic value to hemoglobin, hematocrit, platelet and monocyte. In the criteria of currently slide review, LH-780 and ADVI-2120 analyzers prepared suspect flags of "Blast, Imm NE2, Immature granulocyte, Imm NE1, Left shift, Variant lymphocyte, Atypical lymphocyte, Platelet clumps and NRBC". The New slide review in the XE-2100 analyzer altered the preparations of a smear slide more than a "Platelet clumps flag(${\geq}200unit$), a single flag excluding the "Platelet clumps flag (${\geq}250unit$) and a multiple flag (${\geq}200unit$)". Also, below the 240 unit, medical technologists prepared manual slides selectively according to their evaluations. The automatic reporting rate was 33.4% without alterations, whereas it was 41.0% without alterations, and was thus improved by 7.6%. The slide review rate was 15.2% before using the Q-flag limit, whereas it was 12.1% for a reduce 3.1%. TAT was 45 minutes without the creation alterations of the delta and panic value checks, whereas it was 35 minutes after making alterations of the delta and panic value checks and thus was shortened by 10 minutes. We came to the conclusion that the establishment and operation of delta and panic value checks and slide review criteria suitable for laboratory environment can reduce unnecessary smear slides, re-checking, re-sampling, re-testing, telephone inquiries and concentrated workloads during specific times of the day.

  • PDF

A Study of the Dielectric Characteristics of the Low-k SiOCH Thin Films by Ellipsometry (Ellipsometry를 이용한 Low-k SiOCH 박막의 유전특성에 관한 연구)

  • Yi, In-Hwan;Hwang, Chang-Su;Kim, Hong-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.12
    • /
    • pp.1083-1089
    • /
    • 2008
  • We studied the dielectric characteristics of low-k SiOCH thin films by Ellipsometry. The SiOCH thin films were prepared by deposition of BTMSM precursors on p-Si wafer by CCP-PECVD method. The nano-porous structural organic/inorganic hybrid-type of SiOCH thin films correlated directly to the formation of low dielectrics close to pore(k=1). The structural groups including highly dense pores in SiOCH thin films originated the anisotropic geometry type of network structure directing to complex refractive characteristics of SiOCH single layer on the p-Si wafer. The linearly polarized beam of Xe-ramp in the range from 190 nm to 2100 nm introduced to the surface of SiOCH thin film, and the reflected beam was Elliptically polarized by complex refractive coefficients of SiOCH dipole groups. The amplitude variation $\Psi$ and phase variation $\Delta$ of the relative reflective coefficients between perpendicular and parallel components to the incident plane were measured by Ellipsometry. The complex optical constants n and k as well as the dielectric constant and thickness of SiOCH thin films were driven by the measured value of $\Psi$ and $\Delta$.

A Study of Optical Characteristics Correlated with Low Dielectric Constant of SiOCH Thin Films Through Ellipsometry (Ellipsometry를 이용한 저 유전상수를 갖는 SiOCH박막의 광학특성 연구)

  • Park, Yong-Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.228-233
    • /
    • 2010
  • We studied the optical characteristics correlated with low dielectric constants of low-k SiOCH thin films through ellipsometry. The low-k SiOCH thin films were prepared by CCP-PECVD method using BTMSM(Bis-trimethylsilylmethane) precursors deposited on p-Si wafer. The Si-O-CHx, Si-O-Si, Si-CHx, CHx and Si-H bonding groups were specified by FTIR spectroscopic spectra, and the groups coupled with the nano-porous structural organic/inorganic hybrid-type of SiOCH thin films which has extremely low dielectric constant close to 2.0. The structural groups includes highly dense pore as well as ions in SiOCH thin films affecting to complex refraction characteristics of single layer on the p-Si wafer. The structural complexity originate the complex refractive constants of the films, and resulted the elliptical polarization of the incident linearly polarized light source of Xe-light source in the range from 190 nm to 2100 nm. Phase difference and amplitude ratio between s wave and p wave propagating through SiOCH thin film was studied. After annealing, the amplitude of p wave was reduced more than s wave, and phase difference between p and s wave was also reduced.

Harmonization of Hemolysis Index in Clinical Chemistry Laboratory and Its Application as a Result Verification Tool (화학검사 결과의 검증을 위한 용혈 지수 일치화 도구 개발)

  • Pyo, Sang Shin;Nam, Hyun Su;Cha, Young Jong;Lee, Seungkwan;Lee, Hae Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.350-358
    • /
    • 2017
  • The hemolysis index (HI) is semi-quantitative marker for hemolysis. Because the characteristics of the HI vary from one commercial platform to another, no standardization or harmonization of the HI is currently available. Specimens (N=40) randomly selected from clinical patients were artificially hemolyzed in vitro. The serum of the specimens was then diluted with a 20 mg/dL difference between 0~300 mg/dL based on serum hemoglobin measured using the XE-2100 hematology automation equipment (Sysmex, Japan). Diluted serum was measured using the Hitachi-7600 biochemical automation equipment (Hitachi, Japan) to differentiate between HI and serum hemoglobin. The data showed linearity between HI and serum hemoglobin and that HI 1 contained approximately 20 mg/dL of serum hemoglobin. To determine the blood rejection threshold, the HI was divided into three groups: HI 0~1, HI 4~6, HI 9~15. After another batch of clinical specimens (N=40) was measured using a Hitachi-7600 (Hitachi, Japan), each specimen was moved forward and backward with the piston of the syringe to induce an artificial in vitro hemolysis, then measured again with a Hitachi-7600 (Hitachi, Japan). The percentage difference between the three groups was analyzed by ANOVA or the Kruskal-Wallis test. In the post-test, there were significant differences between the HI 0~1 and the HI 5~6: Glucose, creatinine, total protein, AST, direct bilirubin, uric acid, phosphorus, triglyceride, LDH, CPK, Magnesium, and potassium levels. Because many clinical tests differed significantly, the threshold for hemolysis could be appropriate for HI 5 (serum hemoglobin 100 mg/dL).

Clinical Significance of Immature Reticulocyte as an Early Recovery Indicator after Bone Marrow Transplantation (골수이식 후 미성숙 망상적혈구의 유용성 평가)

  • Seo, Suk Won;Kim, Chun Hee;Chi, Hyun Sook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.27-32
    • /
    • 2004
  • Bone marrow transplantation(BMT) is widely used as curative means of various malignant and nonmalignant hematologic disorders, and early and accurate determination of engraftment is very important for critical management decisions. Reticulocyte counts performed by automated flow cytometric methods is a good indicator of erythropoietic activity and its evaluation has been proposed as an early predictor of bone marrow regeneration. Some reports highlighted the usefulness of the percentage of highly fluorescent reticulocytes and the sum of highly and medium fluorescent reticulocytes(immature reticulocyte fraction, IRF). In Asan Medical Center, the criteria for engraftment following BMT or PBSCT was defined as the first day of a 3-day trend of absolute neutrophil count(ANC)${\geq}500/uL$ and platelet count${\geq}30{\times}10^3/uL$. In 1999, Grotto et al proposed an indidator of bone marrow recovery as the first day on which the IRF was twice the minimum value after bone marrow transplantation. To compare the both criterias, we got consecutive datas of immature reticulocyte fraction, absolute neutrophil count(ANC), WBC count, platelet count and reticulocyte count by XE-2100 automated hematology analyzer(Sysmex Co. Japan) from 33 patients daily after BMT. When compared to standard neutrophil engraftment(10-30 days, $16.2{\pm}4.6days$), IRF engraftment (5-21 days, $11.0{\pm}3.9days$) occured significantly earlier in 87.9% of patients(P<0.05). The mean engraftment day for WBC count(11-29 days, $16.4{\pm}4.3days$) was similar to ANC, but platelet count and reticulocyte count revealed more delayed data (10-49 days, $19.1{\pm}7.4days$ vs 17-64 days, $31.4{\pm}14.1days$). In conclusion, our results confirm that an increase in the immature reticulocyte population is the earliest sign of the hematopoietic recovery after BMT and that automated reticulocyte quantification including immature fraction may be integrated into clinical protocols to evaluate bone marrow reconstitution.

  • PDF