• Title/Summary/Keyword: X-ray method

Search Result 4,385, Processing Time 0.031 seconds

A Study on Three Dimensional Coordinates Analysis Using x-Ray (X-Ray 를 이용한 삼차원(三次元) 좌표해석(座標解析)에 관한 연구(硏究))

  • Yeu, Bock Mo;Park, Joon Kyu;Kim, In Sop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.89-98
    • /
    • 1987
  • X-Ray photogrammetry is the method that register and analize the anatomical or physiological information about the human body by the photography form. In this paper, using X-Ray, accuracy of three dimensional coordinates of objects which are deformed and a part of human body is analyzed. An objective of this analysis lies in improving the accuracy of three dimensional coordinates and enhancing the practical use. Through the observation, X-Ray Photogrammetry is used in practical use. And X-Ray photograph is used the reform of graphical model by the determination of the three dimensional coordinates about all sides of object.

  • PDF

The Compensation of Image Distortion on the X - Ray Image Intensifier (X - Ray 검사 시스템에서 Image Intensifier의 왜곡 보정)

  • Shin, Dong-Chul;Oh, Choon-Suk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.4
    • /
    • pp.1044-1047
    • /
    • 1998
  • Non-destructive x-ray inspection system needs image intensifier to obtain the x-ray image. Captured image from image intensifier is distorted because the input plate of image intensifier has a spherical surface. In the research, in order to compensate this image distortion, we created the model of image intensifier and show mathematically that the image distortion was compensated. To show the performance of the proposed method, experiment was performed in real x-ray inspection system.

  • PDF

Fabrication of ITO-less Sustain Electrodes for High Resolution Plasma Display Panel by X-Ray Lithographic Process

  • Ryu, Seung-Min;Yang, Dong-Yol;So, Jae-Yong;Park, Lee-Soon;Cheong, Hee-Woon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.370-373
    • /
    • 2009
  • X-ray lithography was employed to fabricate ITO-less high resolution sustain electrodes for plasma display panel (PDP). A polyimide film based X-ray mask and Xray sensitive Ag electrode paste were fabricated to check their effect on the patterning of Ag electrodes with less than 30 ${\mu}m$ in width. The X-ray lithographic method was found to be useful for the high resolution sustain electrode patterns due to the high penetration power and low scattering property of X-ray source.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

Three Dimensional Volume Reconstruction of an Object from X-ray Iamges using Uniform and Simultaneous ART (USART 방법에 의한 X선 영상으로부터의 삼차원 물체의 형상 복원)

  • Roh, Young-Jun;Cho, Hyung-Suck;Kim, Hyeong-Cheol;Kim, Jong-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. A number of visual or optical technologies have been successfully applied to measure three-dimensional surfaces. However, those conventional visual or optical methods have inherent shortcomings such as occlusion and variant surface reflection. X-ray vision system can be a good solution to these conventional problems, since we can extract the volume information including both the surface geometry and the inner structure of any objects. In the x-ray system, the surface condition of an object, whether it is lambertian or specular, does not affect the inherent characteristics of its x-ray images. In this paper, we propose a three-dimensional x-ray imaging method to reconstruct a three dimensional structure of an object out of two dimensional x-ray image sets. To achieve this by the proposed method, two or more x-ray images projected from different views are needed. Once these images are acquired, the simultaneous algebraic reconstruction technique(SART) is usually utilized. Since the existing SART algorithms have several shortcomings such as low performance in convergence and different convergence within the reconstruction volume of interest, an advanced SART algorithm named as USART(uniform SART) is proposed to avoid such shortcomings and improve the reconstruction performance. Because, each voxel within the volume is equally weighted to update instantaneous value of its internal density, it can achieve uniform convergence property of the reconstructed volume. The algorithm is simulated on various shapes of objects such as a pyramid, a hemisphere and a BGA model. Based on simulation results the performance of the proposed method is compared with that of the conventional SART method.

The dark-current and X -ray sensitivity measurement of hybrid digital X-ray detector having dielectric layer structure (a-Se 기반의 혼합형 X-선 검출기에서 유전층의 누설전류 저감효과)

  • Seok, Dae-Woo;Park, Ji-Koon;Joh, Jin-Wook;Lee, Dong-Gil;Moon, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.31-34
    • /
    • 2002
  • In this paper, the electric properties of amophous selenium multilayer samples has been investigated. In order to develop the hybrid flat-panel digital· X-ray image detector, we measured and analyzed their performance parameters such as the X -ray sensitivity and dark-current for a amophous selenium multilayers X-ray detector with a phosphor layer, The hybrid digital X-ray image detector can be constructed by integrating a phosphor layer (or a scintillative layer) that convert X-ray to a light on a-Se photoconduction mulilayers that convert a light to electrical signal. As results, the dielectric materials such as parylene between the phosphor layer and the top electrode may reduce the dark-current of the samples. Amorphous selenium multilayers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the hybrid X-ray detector.

  • PDF

X-ray / gamma ray radiation shielding properties of α-Bi2O3 synthesized by low temperature solution combustion method

  • Reddy, B. Chinnappa;Manjunatha, H.C.;Vidya, Y.S.;Sridhar, K.N.;Pasha, U. Mahaboob;Seenappa, L.;Sadashivamurthy, B.;Dhananjaya, N.;Sathish, K.V.;Gupta, P.S. Damodara
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1062-1070
    • /
    • 2022
  • In the present communication, pure and stable α-Bismuth Oxide (Bi2O3) nanoparticles (NPs) were synthesized by low temperature solution combustion method using urea as a fuel and calcined at 500℃. The synthesized sample was characterized by using powder X-ray Diffraction (PXRD), Scanning Electron Microscopy (SEM), Energy dispersive X-ray analysis (EDAX), Transmission Electron Microscopy (TEM), Fourier Transform Infrared Spectroscopy (FTIR) and UV-Visible absorption spectroscopy. The PXRD pattern confirms the formation of mono-clinic, stable and low temperature phase α-Bi2O3. The direct optical energy band gap was estimated by using Wood and Tauc's relation which was found to be 2.81 eV. The characterized sample was studied for X-ray/gamma ray shielding properties in the energy range 0.081-1.332 MeV using NaI (Tl) detector and multi channel analyzer (MCA). The measured shielding parameters agrees well with the theory, whereas, slight deviation up to 20% is observed below 356 keV. This deviation is mainly due to the influence of atomic size of the target medium. Furthermore an accurate theory is necessary to explain the interaction of X-ray/gamma ray with the NPs.The present work opens new window to use this facile, economical, efficient, low temperature method to synthesize nanomaterials for X-ray/gamma ray shielding purpose.

Investigating X-ray cavities and the environmental effects

  • Shin, Jaejin;Woo, Jong-Hak;Mulchaey, John S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.34.2-34.2
    • /
    • 2016
  • X-ray cavities are typically detected as surface brightness depression in X-ray diffuse emission from hot gas in high resolution X-ray images (i.e., Chandra and XMM-Newton). Showing the coincidence of location with radio jets, X-ray cavities imply that the radio jets interact with interstellar/intergalactic medium. It is important to understand them since they can be a clue of understanding AGN feedback to their host galaxies. To understand the physics of the AGN feedback, X-ray cavity has been actively studied while there are only a few statistical studies on X-ray cavity based on small or incomplete samples. Hence, a systematic study with a large sample is needed. With the condition of sufficient X-ray photons to detect surface brightness depression, we constructed a large sample of 133 galaxy clusters, galaxy groups, and individual galaxies to investigate X-ray cavities. We detected 201 cavities from 94 objects using two detection methods (i.e., beta-modeling and unsharp masking method), and confirmed the cavity size-distance relation over a large dynamical range. The size-distance relation does not vary for different environments (i.e., galaxy cluster, groups, and individual galaxies), suggesting that there is little environmental effect on the formation of X-ray cavity.

  • PDF

The Importance of Positioning in General X-ray Examination: Based on Chest PA X-ray (일반엑스선 검사 시 위치 잡이의 중요성: 흉부엑스선 검사 중심으로)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.249-254
    • /
    • 2022
  • The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

Rapid Stitching Method of Digital X-ray Images Using Template-based Registration (템플릿 기반 정합 기법을 이용한 디지털 X-ray 영상의 고속 스티칭 기법)

  • Cho, Hyunji;Kye, Heewon;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.6
    • /
    • pp.701-709
    • /
    • 2015
  • Image stitching method is a technique for obtaining an high-resolution image by combining two or more images. In X-ray image for clinical diagnosis, the size of the imaging region taken by one shot is limited due to the field-of-view of the equipment. Therefore, in order to obtain a high-resolution image including large regions such as a whole body, the synthesis of multiple X-ray images is required. In this paper, we propose a rapid stitching method of digital X-ray images using template-based registration. The proposed algorithm use principal component analysis(PCA) and k-nearest neighborhood(k-NN) to determine the location of input images before performing a template-based matching. After detecting the overlapping position using template-based matching, we synthesize input images by alpha blending. To improve the computational efficiency, reduced images are used for PCA and k-NN analysis. Experimental results showed that our method was more accurate comparing with the previous method with the improvement of the registration speed. Our stitching method could be usefully applied into the stitching of 2D or 3D multiple images.