• Title/Summary/Keyword: X-ray CT 분석

Search Result 197, Processing Time 0.027 seconds

CBCT analysis of three implant cases for treatment planning (임플란트 치료 전 CBCT 영상분석 세 증례)

  • Kim, Jae-Duk;Kim, Kwang-Won;Lim, Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.171-180
    • /
    • 2007
  • The role of radiographic imaging in determining the size, numbers and the position of implants is very important. To perform the implant procedure, the dentist needs to evaluate the bone pathology and bone density, and to know the precise height, width, and contour of the alveolar process, as well as its relationship to the maxillary sinus and mandibular canal. The author analyzed 3 implant cases for treatment planning with the cone beam CT. All axial, panoramic, serial and buccolingual-sectioned images of 3 cases with stent including vertical marker were taken by using Mercuray (Hitachi, Japan). When the curved line drawn intentionally did not include dot image of a vertical marker on the axial image of CBCT, the image of the vertical marker was deformed on its buccolingually sectioned image. There was wide discrepancy in inclination between the alveolar bone and tooth on buccolingually sectioned image.

  • PDF

Early Detection of Sacroilitis by 3-Dimensional Analysis (3차원적 구조분석을 통한 천장관절염의 조기진단)

  • Jun, Jae-Han;Kim, Sun-Il;Lee, Doo-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.100-102
    • /
    • 1992
  • Currently, detection of sacroilitis is necessary in detect ion of ankylosing spondylitis. So early detection of sacroilitis is needed for early detection of ankylosing spondylitis. But it is difficult to detect sacroiliac abnormalities in early stage by conventional plain X-ray. Therefore, it is performed 3-dimensional volume rendering from the CT image of sacroiliac. Then early detection of sacroilitis is made by analyzing the reconstructed 3-dimensional image.

  • PDF

Fast DRR generation for real-time registration (실시간 정합을 위한 고속 DRR 영상 생성)

  • Park, Seong-Jin;Kim, Kye-Hyun;Hong, Helen
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.697-699
    • /
    • 2005
  • 본 논문에서는 그래픽 하드웨어를 이용한 텍스처기반 볼륨렌더링으로 DRR 영상을 고속으로 생성하는 방법을 제안한다. 제안방법은 크게 세단계로 구성된다. 첫째, CT 영상 슬라이스 데이터에서 각 슬라이스를 최인접보간법으로 보간함으로써 등방해상도의 볼륨데이터를 생성한다. 둘째, 그래픽 하드웨어의 메모리용량 때문에 발생하는 문제를 해결하기 위해 텍스처 메모리의 효율적 관리방법을 제시한다. 셋째, 텍스처기반 볼륨렌더링을 이용해서 X-ray 영상과 유사한 투시투영한 DRR 영상을 생성한다. 본 논문에서 제안한 방법을 평가하기 위해서 인공 심장 데이터를 사용한다. 제안방법의 수행시간과 화질을 평가하기 위해서 기존 광선추적법, 복셀투영법을 적용한 DRR 영상과 비교 분석하였다. 실험결과 제안 방법은 기존 방법에 비해서 빠르게 DRR 영상을 생성하였고, 영상의 화질 또한 광선추적법의 결과 영상의 화질만큼 좋은 영상을 생성하였기 때문에 실시간 정합에 적합하였다.

  • PDF

A Study on the 3D Imaging of High Temperature Heating Cement Paste and the Analysis of Variation of the Pore Structure (고온 가열 시멘트 페이스트의 3D 영상화 및 세공구조 변화 분석에 관한 연구)

  • Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.147-148
    • /
    • 2020
  • In case of high temperature damage such as fire, the durability of concrete is reduced due to the collapse of internal pore tissue. Therefore, in this paper, we are going to analyze the pore structure of cement paste hardening agent using MIP analysis and build up 3D data produced using X-ray CT tomography. The test specimen is made of cement paste from W/C 0.4. As the temperature of heating increased, the amount of air gap and the diameter of air gap in cement paste increased. It is judged that the air gap structure inside cement collapsed due to the evaporation of the hydrate, gel count, capillary water, etc. inside the cement due to the high temperature.

  • PDF

Analysis of Secondary Battery Based on Image Processing of Computed Tomography (CT 기반 영상처리를 이용한 이차전지의 분석)

  • Jea-Seok Oh;Sang-Yeol Lee;Yoon-Gi Yang;Keun-Ho Rew
    • Journal of Information Technology Applications and Management
    • /
    • v.29 no.6
    • /
    • pp.13-21
    • /
    • 2022
  • In this study, we presented a method to inspect the mechanical defects of 4680 type lithium-ion batteries through image processing method. The raw X-ray images are filtered with CLAHE, then Radon inverse transformations are calculated to reconstruct 3D computed tomography of the battery. Using Haar-cascade, the ROI is targeted automatically, and the template matchings are applied twice. The variations of contrast between template and background show the appropriate values for detecting tabs. It was shown that the proposed algorithm can detect all the tab inside the battery and the distances between tabs. Finally, we successfully found the geometrical defects of battery.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

Fracture Mechanics Approach to X-Ray Diffraction Method for Spot Welded Lap Joint Structure of Rolled Steel Considered Residual Stress (잔류응력을 고려한 압연강 용접구조물의 X-ray 회절법에 의한 파괴 역학적 고찰)

  • Baek, Seung-Yeb;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1179-1185
    • /
    • 2011
  • Cold and hot-rolled carbon steel sheets are commonly used in railroad cars or commercial vehicles such as the automobile. The sheets used in these applications are mainly fabricated by spot welding, which is a type of electric resistance welding. However, the fatigue strength of a spot-welded joint is lower than that of the base metal because of high stress concentration at the nugget edge of the spot-welded part. In particular, the fatigue strength of the joint is influenced by not only geometrical and mechanical factors but also the welding conditions for the spot-welded joint. Therefore, there is a need for establishing a reasonable criterion for a long-life design for spot-welded structures. In this thesis, ${\Delta}P-N_f$ relation curves have been used to determine a long-life fatigue-design criterion for thin-sheet structures. However, as these curves vary under the influence of welding conditions, mechanical conditions, geometrical factors, etc. It is very difficult to systematically determine a fatigue-design criterion on the basis of these curves. Therefore, in order to eliminate such problems, the welding residual stresses generated during welding and the stress distributions around the weld generated by external forces were numerically and experimentally analyzed on the basis of the results, reassessed fatigue strength of gas welded joints.

Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study (비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구)

  • So Jung Ki;Chul Hwan Park;Kyunghwa Han;Jae Min Shin;Ji Young Kim;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1493-1504
    • /
    • 2021
  • Purpose This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. Materials and Methods This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calcium-score CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. Results The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. Conclusion The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.

Characterization of coated colorless synthetic moissanite (코팅된 무색 합성 모이사나이트의 특징)

  • Choi, Hyunmin;Kim, Youngchool;Jang, Hansoo;Seok, Jeongwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.1
    • /
    • pp.7-11
    • /
    • 2022
  • Recently, Hanmi Gemological Institute & Laboratory (HGI) had an opportunity to examine 5 transparent synthetic moissanite. The round brilliants ranged from 0.93 to 0.96 ct and had a colorless, pink, yellow, blue, and red color. Advanced testing results, including Fourier-transform infrared (FTIR) and Raman spectroscopy, identified all the specimens as synthetic moissanite. Under the microscope, all samples except the colorless were confirmed to be a synthetic moissanite coated with a colored film. EDXRF chemical analysis detected very weak X-ray fluorescence peak characteristics of Ca, Ti, and Co in the colored samples. These features were not detected in the colorless sample. Raman spectroscopy investigation was unable to detect the 1332 cm-1 (produced by sp3 bonding of carbon atoms) or the ~1550 cm-1 (produced by graphite-related sp2 bonding) peak in the colorless sample. The SEM image of the colorless sample showed no indication of a coating. The TEM image of the colorless sample revealed the presence of a 3~8 nm thick layer on the moissanite. Moreover, from the corresponding STEM Z-contrast image combined with the energy-dispersive X-ray spectroscopy (EDX) line profiles and EDX elemental maps, this layer was estimated to be carbon, silicon and oxygen.

Studies on Quantitative Analysis of Salivary Gland using Computed Tomography (전산화단층사진을 이용한 타액선의 정량분석에 관한 연구)

  • Lee Sang-Chul;Lee Sam-Sun;Heo Min-Suk;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.209-221
    • /
    • 1999
  • Purpose: The purpose of this study was to calculate the size and CT number of both normal parotid and submandibular gland. and evaluate their relation to sex, age and obesity using computed tomography. Materials and Methods: The computed tomography was performed parallel to the Frankfurt plane in 46 subjects with healthy salivary gland. The subjects were divided into the three groups (young, middle. old) according to their ages. The size of salivary gland was determined as maximum cross-sectional area and the CT number of salivary gland was determined as the mean CT number of three ROI's. The body mass index was calculated from weight and height. Results: The mean maximum cross-sectional area was 7.79(±1.25)cm² on parotid gland and 4.12(±0.83) cm² on submandibular gland. The mean CT number was -4.43(±23.87) HU on parotid gland and 50.01(±15.63) HU on submandibular gland. There was decreasing pattern of the maximum cross-sectional area of submandibular gland and the CT number of both parotid and submandibular gland according to age(p<0.05). As the body mass index increased. the maximum cross-sectional area of parotid gland increased and CT number of both parotid and submandibular gland decreased(p<0.05). The maximum cross-sectional area of submandibular gland in male was larger than that in female(p<0.05). As the maximum cross-sectional area and CT number of left salivary gland increased. those of right gland increased(p<0.05). Conclusion : Intra-individual differences in salivary gland size and CT number is considered in the age and individual obesity.

  • PDF