• Title/Summary/Keyword: X type

Search Result 4,646, Processing Time 0.036 seconds

Study of the Mobility for Strained p-type $Si_{1-x}Ge_x$ Alloys (변형 힘을 받는 p형 $Si_{1-x}Ge_x$의 이동도 연구)

  • 전상국
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.3
    • /
    • pp.181-187
    • /
    • 1998
  • The ionization energy and degree of ionization for p-type $Si_{1-x}Ge_x$ with boron doping are calculated taking into account the screening and broadening effects. The drift and Hall mobilities are then calculated using the relaxation time approximation and compared with the previously reported measurement data for relaxed and strained $Si_{1-x}Ge_x$ alloys to estimate the alloy scattering potential. From a fit, the alloy scattering potential is found to be 0.5 eV. The in-plane drift mobility for p-type strained $Si_{1-x}Ge_x$ grown on (001) Si substrate is approximately 1+$10x^2$ times higher than that for bulk Si in the high doping range.

  • PDF

EXISTENCE OF HOMOCLINIC ORBITS FOR LIENARD TYPE SYSTEMS

  • Kim, Yong-In
    • The Pure and Applied Mathematics
    • /
    • v.17 no.4
    • /
    • pp.389-396
    • /
    • 2010
  • We investigate the existence of homoclinic orbits of the following systems of $Li{\'{e}}nard$ type: $a(x)x^'=h(y)-F(x)$, $y^'$=-a(x)g(x), where $h(y)=m{\mid}y{\mid}^{p-2}y$ with m > 0 and p > 1 and a, F, 9 are continuous functions such that a(x) > 0 for all $x{\in}{\mathbb{R}}$ and F(0)=g(0)=0 and xg(x) > 0 for $x{\neq}0$. By a series of time and coordinates transformations of the above system, we obtain sufficient conditions for the positive orbits of the above system starting at the points on the curve h(y) = F(x) with x > 0 to approach the origin through only the first quadrant. The method of this paper is new and the results of this paper cover some early results on this topic.

STUDY OF FLARE-ASSOCIATED X-RAY PLASMA EJECTIONS : II. MORPHOLOGICAL CLASSIFICATION

  • KIM YEON-HAN;MOON Y.-J.;CHO K.-S.;BONG SU-CHAN;PARK Y.-D.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.171-177
    • /
    • 2004
  • X-ray plasma ejections often occurred around the impulsive phases of solar flares and have been well observed by the SXT aboard Yohkoh. Though the X-ray plasma ejections show various morphological shapes, there has been no attempt at classifying the morphological groups for a large sample of the X-ray plasma ejections. In this study, we have classified 137 X-ray plasma ejections according to their shape for the first time. Our classification criteria are as follows: (1) a loop type shows ejecting plasma with the shape of loops, (2) a spray type has a continuous stream of plasma without showing any typical shape, (3) a jet type shows collimated motions of plasma, (4) a confined ejection shows limited motions of plasma near a flaring site. As a result, we classified the flare-associated X-ray plasma ejections into five groups as follows: loop-type (60 events), spray-type (40 events), jet-type (11 events), confined ejection (18 events), and others (8 events). As an illustration, we presented time sequence images of several typical events to discuss their morphological characteristics, speed, CME association, and magnetic field configuration. We found that the jet-type events tend to have higher speeds and better association with CMEs than those of the loop-type events. It is also found that the CME association (11/11) of the jet-type events is much higher than that (5/18) of the confined ejections. These facts imply that the physical characteristics of the X-ray plasma ejections are closely associated with magnetic field configurations near the reconnection regions.

A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications (진단용 X선장치의 성능 실태 조사연구)

  • Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

Clinical Application of Inverter type X-ray Generator (Inverter 방식(方式) X선장치(X線裝置)의 임상응용(臨床應用))

  • Lee, Sun-Sook;Huh, Joon;Lee, Jea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Inverter type X-ray apparatus has been introduced and used several hospitals. Principle of inverter type X-ray generators are such as to convert the frequency of commercial power supply to high frequency and to control the high voltages for X-ray tube. Inverter generators are now on the way for futher development to elliminate single phase generators and three phase generators. We compared inverter type X-ray apparatus with conventional single phase 2 peak and three phase 12 peak, apparatus in the following aspects X-ray out put to tube voltage, linearity of X-ray out put to mA, HVL according to mA contrast to kV.

  • PDF

ON STABILITY OF THE ORTHOGONALLY CUBIC TYPE FUNCTIONAL EQUATION

  • Chang, Ick-Soon
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.19 no.3
    • /
    • pp.275-281
    • /
    • 2006
  • In this article, we establish the stability of the orthogonally cubic type functional equation 2f(x + 2y) + 2f(x - 2y) + 2f(2x)+7[f(x)+f(-x)] = 4f(x)+8[f(x+y)+f(x-y)], $x{\bot}y$ in which ${\bot}$ is the orthogonality in the sense in the R$\ddot{a}$tz.

  • PDF

MULTIPLE SOLUTIONS FOR EQUATIONS OF p(x)-LAPLACE TYPE WITH NONLINEAR NEUMANN BOUNDARY CONDITION

  • Ki, Yun-Ho;Park, Kisoeb
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.6
    • /
    • pp.1805-1821
    • /
    • 2016
  • In this paper, we are concerned with the nonlinear elliptic equations of the p(x)-Laplace type $$\{\begin{array}{lll}-div(a(x,{\nabla}u))+{\mid}u{\mid}^{p(x)-2}u={\lambda}f(x,u) && in\;{\Omega}\\(a(x,{\nabla}u)\frac{{\partial}u}{{\partial}n}={\lambda}{\theta}g(x,u) && on\;{\partial}{\Omega},\end{array}$$ which is subject to nonlinear Neumann boundary condition. Here the function a(x, v) is of type${\mid}v{\mid}^{p(x)-2}v$ with continuous function $p:{\bar{\Omega}}{\rightarrow}(1,{\infty})$ and the functions f, g satisfy a $Carath{\acute{e}}odory$ condition. The main purpose of this paper is to establish the existence of at least three solutions for the above problem by applying three critical points theory due to Ricceri. Furthermore, we localize three critical points interval for the given problem as applications of the theorem introduced by Arcoya and Carmona.

Electrical Properties of (PbS)$_{1-x}-(CuS)_{x}$ Thin Films by Chemical Bath Deposition (CBD 방법에 의한 (PbS)$_{1-x}-(CuS)_{x}$ 박막의 전기적 특성)

  • 조종래;조정호;김강언;정수태;조상희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.13-16
    • /
    • 2000
  • (PbS)$_{1-x}$ -(CuS)$_{x}$ thin films(x=0, 0.5, 1) were grown on glass substrates by using a chemical bath deposition method. The molecular ratio of Pb to Cu for the PbS-CuS thin films(x=0.5) was measured about 7:3 by using EDX and XRF. The resistivity of non-annealed (PbS)$_{1-x}$ -(CuS)$_{x}$ thin films was about 10 $\Omega$ . cm. However, after annealing, the resistivity of PbS showed a little change, while PbS-CuS and CuS significantly decreased in the range of 0.002 to 0.005$\Omega$.cm. PbS was p-type and CuS was n-type.-type.

  • PDF

Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine (이동형 구내 방사선촬영기로 촬영한 치근단 방사선사진의 흡수선량 및 유효선량 평가)

  • Cho, Jeong-Yeon;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.149-156
    • /
    • 2007
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. Materials and Methods: 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. Results: On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Conclusion: Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines.

  • PDF

Investigation of X-ray-induced Defects on Metals and Silicon by Using Coincidence Doppler Broadening Positron Annihilation Spectroscopy

  • Lee, C.Y.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1895-1898
    • /
    • 2018
  • The mechanical properties of Al, Ti, Fe, and Cu metals p-type Si, and n-type Si were investigated by using coincidence Doppler broadening (CDB) positron annihilation spectroscopy. The samples in this experiment were irradiated by using X-rays at generating powers for up to 9 kW. The data taken after the irradiation showed all the characteristic features predicted from defects with vacancies. The S parameter values of the metals were generally less than those of semiconductors such as p-type Si and n-type Si. The relationship between n-type Si and p-type Si were more affected when n-type Si rather than p-type Si was irradiated with X-rays.